Presence and concentrations of radionuclides could be as a result of natural and human activities. This study examined the associations and differences among soil, sediment and water specific activities of long-lived radioactive element (LLRE). Gamma spectroscopy was used to measure the concentration of the LLRE along the Mini Okoro/Oginigba Creek, Port Harcourt. Specific activities of three selected LLRE were derived. Correlation analysis was carried out to examine associations among the specific activities across different substrates. A strong and a significant negative correlation exists between the specific activities of Water 40K and Soil 232Th (r =-0.721, p<0.05); Water 238U and Soil 238U (r = -0.717, p<0.05) and Water 40K and Sediment 238U (r=-0.69, p<0.05). Comparison using Mann-Whitney U test shows that, soil and sediment are similar in their specific activities with Z values of -0.408, -1.209 and -1.021 (p > 0.05) for 40K, 232Th and 238U respectively. The concentration of solid samples (soil and sediment) is different from the liquid (water) samples. These associations can be attributed to some specific underlying factors. And in other to understand them there is need for more studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Twenty one sampling locations were assessed for carbon monoxide (CO), carbondioxide (CO2), oxygen (O2), sulphur dioxide (SO2), nitrogen dioxide (NO2), nitrogen oxide (NO), suspended particulate matter (SPM) and noise level using air pollutants measurement methods approved by ASTM for each specific parameter. All equipments and meters were all properly pre-calibrated before each usage for quality assurance. Findings of the study showed that measured levels of noise (61.4 - 101.4 dBA), NO (0.0 - 3.0 ppm), NO2 (0.0 - 3.0 ppm), CO (1.0 – 42.0 ppm) and SPM (0.14 – 4.82 ppm) in all sampling areas were quite high and above regulatory limits however there was no significant difference except in SPM (at all the sampling points), and noise, NO2 and NO (only in major traffic intersection). Air quality index (AQI) indicates that the ambient air can be described as poor for SPM, varied from good to very poor for CO, while NO and NO2 are very good except at major traffic intersection where they were both poor and very poor (D-E). The results suggest that strict and appropriate vehicle emission management, industrial air pollution control coupled with close burning management of wastes should be considered in the study area to reduce the risks associated with these pollutants.