3 resultados para Occupational and Environmental Medicine

em Bioline International


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Aspergillosis has been identified as one of the hospital acquired infections but the contribution of water and inhouse air as possible sources of Aspergillus infection in immunocompromised individuals like HIV-TB patients have not been studied in any hospital setting in Nigeria. Objective: To identify and investigate genetic relationship between clinical and environmental Aspergillus species associated with HIV-TB co infected patients. Methods: DNA extraction, purification, amplification and sequencing of Internal Transcribed Spacer (ITS) genes were performed using standard protocols. Similarity search using BLAST on NCBI was used for species identification and MEGA 5.0 was used for phylogenetic analysis. Results: Analyses of sequenced ITS genes of selected fourteen (14) Aspergillus isolates identified in the GenBank database revealed Aspergillus niger (28.57%), Aspergillus tubingensis (7.14%), Aspergillus flavus (7.14%) and Aspergillus fumigatus (57.14%). Aspergillus in sputum of HIV patients were Aspergillus niger, A. fumigatus, A. tubingensis and A. flavus. Also, A. niger and A. fumigatus were identified from water and open-air. Phylogenetic analysis of sequences yielded genetic relatedness between clinical and environmental isolates. Conclusion: Water and air in health care settings in Nigeria are important sources of Aspergillus sp. for HIV-TB patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To investigate the knowledge and use of asthma control measurement (ACM) tools in the management of asthma among doctors working in family and internal medicine practice in Nigeria. Method: A questionnaire based on the global initiative on asthma (GINA) guideline was self-administered by 194 doctors. It contains 12 test items on knowledge of ACM tools and its application. The knowledge score was obtained by adding the correct answers and classified as good if the score ≥ 9, satisfactory if score was 6-8 and poor if < 6. Results: The overall doctors knowledge score of ACM tools was 4.49±2.14 (maximum of 12). Pulmonologists recorded the highest knowledge score of 10.75±1.85. The majority (69.6%) had poor knowledge score of ACM tools. Fifty (25.8%) assessed their patients’ level of asthma control and 34(17.5%) at every visit. Thirty-nine (20.1%) used ACM tools in their consultation, 29 (15.0%) of them used GINA defined control while 10 (5.2 %) used asthma control test (ACT). The use of the tools was associated with pulmonologists, having attended CME within six months and graduated within five years prior to the survey. Conclusion: The results highlight the poor knowledge and use of ACM tools and the need to address the knowledge gap.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main aim of this study was to analyze evidence of an environmental Kuznets curve for water pollution in the developing and developed countries. The study was conducted based on a panel data set of 54 countries – that were categorized into six groups of “developed countries”, “developing countries”, “developed countries with low income”, “developed countries with high income” and “coastal countries”- between the years 1995 to 2006. The results do not confirm the inverted U-shape of EKC curve for the developed countries with low income. Based on the estimated turning points and the average GDP per capita, the study revealed at which point of the EKC the countries are. Furthermore, impacts of capital-and-labor ratio as well as trade openness are drawn by estimating different models for the EKC. The magnitude role of each explanatory variable on BOD was calculated by estimating the associated elasticity.