2 resultados para Lead-time and set-up optimization
em Bioline International
Resumo:
To determine the ameliorative effect of coconut water on haematobiochemical changes due to lead poisoning in wistar albino rats for six weeks, sixty rats were assigned to four groups. 0.10g/l of lead and 75ml coconut ( cocus nucifera l.) water were given orally for six weeks. The mean values of red blood cells, mean corpuscular volume, mean corpuscular haemoglobin, mean corpuscular haemoglobin concentration, red blood cell distribution width and platelets (8.10±0.63(×106μl), 52.7±0.87(μm3), 17.9±0.56(pg), 34.73±0.65(g/dl), 17.90±0.67(%) and 670.00±42.22(×103μl) respectively) reduced in lead treated rats when compared with control mean values (8.41 ± 0.90(×106μl), 56.60 ± 1.55(μm3), 19.33 ± 0.82(pg), 34.93 ± 0.90(g/dl), 18.27 ± 0.73(%) and 818.33± 123.68(×103μl) respectively ) and these values increased in75ml coconut water only group and the group of 0.10g/l lead + 75ml coconut water except mean corpuscular haemoglobin, mean corpuscular haemoglobin concentration, and red blood cell distribution width of the 75ml coconut water only. The mean values of white blood cells, lymphocytes, total cholesterol, triglyceride, high density lipoprotein-cholesterol, low density lipoprotein-cholesterol, low density lipoprotein-cholesterol/high density lipoproteincholesterol and total cholesterol/high density lipoprotein-cholesterol increased (12.23±0.57(×103μl), 79.83±3.87(%), 64.66±6.01(mg/dl), 89.00±7.94(mg/dl), 22.67±6.93(mg/dl), 21.00±4.58(mg/dl), 1.29±0.62 and 3.36±0.83 respectively ) in the lead group when compared with mean values of control group (5.83±0.74(×103μl), 69.07±10.57(%), 54.00±4.04(mg/dl), 97.33±11.34(mg/dl), 20.00±3.06(mg/dl), 17.00±6.51(mg/dl), 0.97±0.41 and 2.87±0.55 respectively) but the mean values decreased when compared with the mean values of group of 75ml coconut water only and group of 0.10g/l lead + 75ml coconut water, except the mean values of high density lipoprotein-cholesterol. These results indicate that coconut water could ameliorate effects of lead toxicity
Resumo:
Introduction: Infantile hemangiomas of the airway are diagnosed at bronchoscopy as part of the investigation of stridor or other respiratory symptoms. Here, we present three-dimensional computed tomography (3D-CT)/bronchoscopy findings of submucosal subglottic hemangioma missed at bronchoscopy. Case Presentation: We report on the clinical usefulness of 3D-CT/bronchoscopy as the primary diagnostic tool and follow-up method in the evaluation of suspected airway infantile hemangiomas, especially when the hemangioma is the submucosal type. Conclusions: 3D-CT/bronchoscopy will reduce the need for invasive laryngoscopic studies and help to diagnose submucosal hemangiomas undetected on laryngoscope. Additionally, 3D-CT/bronchoscopy will help evaluating the extent of the lesion, degree of airway narrowing, and treatment response.