2 resultados para Developing World Debt Crisis

em Bioline International


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Vitamin A (VA) deficiency (VAD) is a major nutritional public health problem among children under-5-years-old in the developing world including Kenya. A community-based cross-sectional survey among 1,630 children (aged 6-23 mos) was undertaken in Western Kenya. A questionnaire was administered to collect demographic, socio-economic and dietary intake information. Prevalence of low retinol-binding protein (RBP) concentrations was assessed using Dried Blood Spot (DBS) methodology. Analysis of RBP was carried out using rapid enzyme immunoassay (EIA) and C-reactive protein (CRP) was carried out using enzyme linked immunosorbent assay (ELISA) to estimate VA and sub-clinical inflammation statuses, respectively. Values were adjusted for influence of inflammation using CRP (CRP >5 mg/L) and population prevalence of VAD (RBP <0.825 μmol/L, biologically equivalent to 0.70 μmol/L retinol) estimated. Anthropometric data gave three indices: stunting, wasting and underweight—all of which took age and sex into consideration. Mean (geometric± SD) concentration of RBP was adequate (1.56±0.79μmol/L) but the inflammation-adjusted mean (±SE) prevalence of VAD was high (20.1±1.1%) in this population. The level of CRP was within normal range (1.06±4.95 mg/L) whilst 18.4±0.9% of the children had subclinical inflammation (CRP>5 mg/L). Intake of VA capsule (VAC) by a child was a predictor of VAD with children who have not taken VA during the past 1 year prior to the survey having a 30% increased risk of VAD (OR (CI): 1.3 (1.1-1.7); p=0.025. Additionally, age of the child was a predictor with older children (18-23 mos) having a 30 % increased risk of VAD (OR (CI): 1.3 (1.1-1.9); p=0.035); the caretaker’s knowledge on VA and nutrition was also a predictor of VAD with children whose caretaker’s had poor knowledge having a 40 % increased risk of VAD (OR (CI): 1.4 (1.0-1.9); p=0.027. A child’s district of residence was also a significant predictor of VAD. Prevalence of VAD in this sample of infants was high. Predictors of VAD included child intake of VAC in the last 1 year before the survey, older children, children whose caretakers had poor VA and nutritional knowledge and a child’s district of residence. There is a need to improve knowledge on nutrition and VA of caretakers; undertake a targeted VAC distribution, particularly in children older than 1 year and above and use a sustainable food-based intervention in the areas with severe VAD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Transcatheter closure of atrial septal defects (ASD) has been accepted world-wide as an alternative to surgical closure with excellent results. This interventional, non-surgical technique plays an important role in the treatment of ASD mostly in the developing world where resources are limited. Objectives: To report the outcomes and short term follow-up of transcatheter closure of ASD over a 12-year period at our institution with limited resources. Patients and Methods: This retrospective study included all patients with the diagnosis of secundum ASD and significant shunting (Qp/Qs > 1.5:1) as well as dilated right atrium and right ventricle who had transcatheter closure at Integrated Cardiovascular Center (PJT), Dr. Cipto Mangunkusumo Hospital between October 2002 and October 2014. One hundred fifty-two patients enrolled in this study were candidates for device closure. Right and left heart cardiac catheterization was performed before the procedure. All patients underwent physical examination, ECG, chest X-ray and transthoracal echocardiography (TTE) prior to device implantation. Results: A total of 152 patients with significant ASD underwent device implantation. Subjects’ age ranged from 0.63 to 69.6 years, with median 9.36 years and mean 16.30 years. They consisted of 33 (21.7%) males and 119 (78.3%) females, with mean body weight of 29.9 kg (range 8 to 75; SD 18.2). The device was successfully implanted in 150 patients where the majority of cases received the Amplatzer septal occluder (147/150; 98%) and the others received the Heart Lifetech ASD occluder (3/150, 2%), whereas two other cases were not suitable for device closure and we decided for surgical closure. The mean ASD size was 19.75 (range 14 - 25) mm. During the procedure, 5 (4.9%) patients had bradycardia and 3 (2.9%) patients had supraventricular tachycardia (SVT), all of which resolved. Conclusions: In our center with limited facilities and manpower, transcatheter closure of atrial septal defect was effective and safe as an alternative treatment to surgery. The outcome and short-term follow-up revealed excellent results, but long-term follow-up is needed.