4 resultados para Abstract test

em Bioline International


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To estimate the prevalence and factors associated with the performance of mammography and pap smear test in women from the city of Maringá, Paraná. Methods: Population-based cross-sectional study conducted with 345 women aged over 20 years in the period from March 2011 to April 2012. An interview was carried out using a questionnaire proposed by the Ministry of Health, which addressed sociodemographic characteristics, risk factors for chronic noncommunicable diseases and issues related to mammographic and pap screening. Data were analyzed using bivariate analysis, crude analysis with odds ratio (OR) and chi-squared test using Epi Info 3.5.1 program; multivariate analysis using logistic regression was performed using the software Statistica 7.1, with a significance level of 5% and a confidence interval of 95%. Results: The mean age of the women was 52.19 (±5.27) years. The majority (56.5%) had from 0 to 8 years of education. Additionally, 84.6% (n=266) of the women underwent pap smear and 74.3% (n=169) underwent mammography. The lower performance of pap smear test was associated with women with 9-11 years of education (p=0.01), and the lower performance of mammography was associated with women without private health insurance (p<0.01). Conclusion: The coverage of mammography and pap smear test was satisfactory among the women from Maringá, Paraná. Low education level and women who depended on the public health system presented lower performance of mammography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Rabies causes 55, 000 annual human deaths globally and about 10,000 people are exposed annually in Nigeria. Diagnosis of animal rabies in most African countries has been by direct microscopic examination. In Nigeria, the Seller’s stain test (SST) was employed until 2009. Before then, both SST and dFAT were used concurrently until the dFAT became the only standard method. Objective: This study was designed to assess the sensitivity and specificity of the SST in relation to the ‘gold standard’ dFAT in diagnosis of rabies in Nigeria. Methods: A total of 88 animal specimens submitted to the Rabies National Reference Laboratory, Nigeria were routinely tested for rabies by SST and dFAT. Results: Overall, 65.9% of the specimens were positive for rabies by SST, while 81.8% were positive by dFAT. The sensitivity of SST in relation to the gold standard dFAT was 81.0% (95% CIs; 69.7% - 88.6%), while the specificity was 100% (95% CIs; 76% - 100%). Conclusion: The relatively low sensitivity of the SST observed in this study calls for its replacement with the dFAT for accurate diagnosis of rabies and timely decisions on administration of PEP to prevent untimely deaths of exposed humans.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background The 2011 Malawi HIV guidelines promote CD4 monitoring for pre-ART assessment and considering HIVRNA monitoring for ART response assessment, while some clinics used CD4 for both. We assessed clinical ordering practices as compared to guidelines, and determined whether the samples were successfully and promptly processed. Methods We conducted a retrospective review of all patients seen in from August 2010 through July 2011,, in two urban HIV-care clinics that utilized 6-monthly CD4 monitoring regardless of ART status. We calculated the percentage of patients on whom clinicians ordered CD4 or HIVRNA analysis. For all samples sent, we determined rates of successful labprocessing, and mean time to returned results. Results Of 20581 patients seen, 8029 (39%) had at least one blood draw for CD4 count. Among pre-ART patients, 2668/2844 (93.8%) had CD4 counts performed for eligibility. Of all CD4 samples sent, 8082/9207 (89%) samples were successfully processed. Of those, mean time to processing was 1.6 days (s.d 1.5) but mean time to results being available to clinician was 9.3 days (s.d. 3.7). Regarding HIVRNA, 172 patients of 17737 on ART had a blood draw and only 118/213 (55%) samples were successfully processed. Mean processing time was 39.5 days (s.d. 21.7); mean time to results being available to clinician was 43.1 days (s.d. 25.1). During the one-year evaluated, there were multiple lapses in processing HIVRNA samples for up to 2 months. Conclusions Clinicians underutilize CD4 and HIVRNA as monitoring tools in HIV care. Laboratory processing failures and turnaround times are unacceptably high for viral load analysis. Alternative strategies need to be considered in order to meet laboratory monitoring needs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Nosocomial sepsis (NS) in newborns (NBs) is associated with high mortality rates and low microbial recovery rates. To overcome the latter problem, new techniques in molecular biology are being used. Objectives: To evaluate the diagnostic efficacy of SeptiFast test for the diagnosis of nosocomial sepsis in the newborn. Materials and Methods: 86 blood specimens of NBs with suspected NS (NOSEP-1 Test > 8 points) were analyzed using Light Cycler SeptiFast (LC-SF) a real-time multiplex PCR instrument. The results were analyzed with the Roche SeptiFast Identification Software. Another blood sample was collected to carry out a blood culture (BC). Results: Sensitivity (Sn) and specificity (Sp) of 0.69 and 0.65 respectively, compared with blood culture (BC) were obtained for LC-SF. Kappa index concordance between LC-SF and BC was 0.21. Thirteen (15.11%) samples were BC positive and 34 (31.39%) were positive with LC-SF tests. Conclusions: Compared with BC, LC-SF allows the detection of a greater number of pathogenic species in a small blood sample (1 mL) with a shorter response time.