7 resultados para ultrasound-assisted treatment
em Digital Commons at Florida International University
Resumo:
One hundred seventy-nine occupational therapists (OTs) responded to a survey regarding their interests and attitudes toward animal assisted therapy as a treatment modality. It was found that most of the practitioners would be interested in learning more about animal assisted therapy and most felt it is a valid treatment modality to be used by occupational therapists. Furthermore, the most common answer to the question "why would you not be interested in participating in an AAT program," was "I feel I don't know enough about it". It was also found that therapists' most commonly selected patient goals for AAT were in the realm of mental health, whereas the least mentioned goals were more physically based goals. Further, a recommendation was made to educate OTs regarding the uses and benefits of AAT through more research, continuing education programs on AAT, publications in professional journals, and media awareness.
Resumo:
Three-Dimensional (3-D) imaging is vital in computer-assisted surgical planning including minimal invasive surgery, targeted drug delivery, and tumor resection. Selective Internal Radiation Therapy (SIRT) is a liver directed radiation therapy for the treatment of liver cancer. Accurate calculation of anatomical liver and tumor volumes are essential for the determination of the tumor to normal liver ratio and for the calculation of the dose of Y-90 microspheres that will result in high concentration of the radiation in the tumor region as compared to nearby healthy tissue. Present manual techniques for segmentation of the liver from Computed Tomography (CT) tend to be tedious and greatly dependent on the skill of the technician/doctor performing the task. ^ This dissertation presents the development and implementation of a fully integrated algorithm for 3-D liver and tumor segmentation from tri-phase CT that yield highly accurate estimations of the respective volumes of the liver and tumor(s). The algorithm as designed requires minimal human intervention without compromising the accuracy of the segmentation results. Embedded within this algorithm is an effective method for extracting blood vessels that feed the tumor(s) in order to plan effectively the appropriate treatment. ^ Segmentation of the liver led to an accuracy in excess of 95% in estimating liver volumes in 20 datasets in comparison to the manual gold standard volumes. In a similar comparison, tumor segmentation exhibited an accuracy of 86% in estimating tumor(s) volume(s). Qualitative results of the blood vessel segmentation algorithm demonstrated the effectiveness of the algorithm in extracting and rendering the vasculature structure of the liver. Results of the parallel computing process, using a single workstation, showed a 78% gain. Also, statistical analysis carried out to determine if the manual initialization has any impact on the accuracy showed user initialization independence in the results. ^ The dissertation thus provides a complete 3-D solution towards liver cancer treatment planning with the opportunity to extract, visualize and quantify the needed statistics for liver cancer treatment. Since SIRT requires highly accurate calculation of the liver and tumor volumes, this new method provides an effective and computationally efficient process required of such challenging clinical requirements.^
Resumo:
An alternating treatment design was used to compare the effects of three student response conditions (Clicking, Repeating, and Listening) during computer-assisted instruction on social-studies facts learning and maintenance. Results showed that all students learned and maintained more social-studies facts taught in the Repeating condition followed by the Clicking condition.
Resumo:
Drug targeting is an active area of research and nano-scaled drug delivery systems hold tremendous potential for the treatment of neoplasms. In this study, a novel cyclodextrin (CD)-based nanoparticle drug delivery system has been assembled and characterized for the therapy of folate receptor-positive [FR(+)] cancer. Water-soluble folic acid (FA)-conjugated CD carriers (FACDs) were successfully synthesized and their structures were confirmed by 1D/2D nuclear magnetic resonance (NMR), matrix-assisted laser desorption ionization time-of-flight mass spectrometer (MALDI-TOF-MS), high performance liquid chromatography (HPLC), Fourier transform infrared spectroscopy (FTIR), and circular dichroism. Drug complexes of adamatane (Ada) and cytotoxic doxorubicin (Dox) with FACD were readily obtained by mixed solvent precipitation. The average size of FACD-Ada-Dox was 1.5–2.5 nm. The host-guest association constant Ka was 1,639 M−1 as determined by induced circular dichroism and the hydrophilicity of the FACDs was greatly enhanced compared to unmodified CD. Cellular uptake and FR binding competitive experiments demonstrated an efficient and preferentially targeted delivery of Dox into FR-positive tumor cells and a sustained drug release profile was seen in vitro. The delivery of Dox into FR(+) cancer cells via endocytosis was observed by confocal microscopy and drug uptake of the targeted nanoparticles was 8-fold greater than that of non-targeted drug complexes. Our docking results suggest that FA, FACD and FACD-Ada-Dox could bind human hedgehog interacting protein that contains a FR domain. Mouse cardiomyocytes as well as fibroblast treated with FACD-Ada-Dox had significantly lower levels of reactive oxygen species, with increased content of glutathione and glutathione peroxidase activity, indicating a reduced potential for Dox-induced cardiotoxicity. These results indicate that the targeted drug complex possesses high drug association and sustained drug release properties with good biocompatibility and physiological stability. The novel FA-conjugated β-CD based drug complex might be promising as an anti-tumor treatment for FR(+) cancer.
Resumo:
The purpose of this study was to compare the effects of three student response conditions during computer-assisted instruction on the acquisition and maintenance of social-studies facts. Two of the conditions required active student responding (ASR), whereas the other required an on-task (OT) response. Participants were five fifth-grade students, with learning disabilities enrolled in a private school. An alternating treatments design with a best treatments phase was used to compare the effects of the response procedures on three major dependent measures: same-day tests, next-day tests, and maintenance tests. ^ Each week for six weeks, participants were provided daily one-to-one instruction on sets of 21 unknown social-studies facts using a hypermedia computer program, with a new set of facts being practiced each week. Each set of 21 facts was divided randomly into three conditions: Clicking-ASR, Repeating-ASR, and Listening-OT. Hypermedia lesson began weekly with the concept introduction lesson, followed by practice and testing. Practice and testing occurred four days per week, per set. During Clicking-ASR, student practice involved the selection of a social-studies response by clicking on an item with the mouse on the hypermedia card. Repeating-ASR instruction required students to orally repeat the social-studies facts when prompted by the computer. During Listening-OT, students listened to the social-studies facts being read by the computer. During weeks seven and eight, instruction occurred with seven unknown facts using only the best treatment. ^ Test results show that all for all 5 students, the Repeating-ASR practice procedure resulted in more social-studies facts stated correctly on same-day tests, next-day tests, and one-and two-week maintenance tests. Clicking-ASR was the next most effective procedure. During the seventh and eighth week of instruction when only the best practice condition was implemented, Repeating-ASR produced higher scores than all conditions (including Repeating-ASR) during the first six weeks of the study. ^ The results lend further support to the growing body of literature that demonstrates the positive relation between ASR and student achievement. Much of the ASR literature has focused on the effects of increased ASR during teacher-led or peer-mediated instruction. This study adds a dimension to that research in that it demonstrated the importance of ASR during computer-assisted instruction and further suggests that the type of ASR used during computer-assisted instruction may influence learning. Future research is needed to investigate the effectiveness of other types of ASR during computer-assisted instruction and to identify other fundamental characteristics of an effective computer-assisted instruction. ^
Resumo:
The purpose of this study was to evaluate the evidence for the effectiveness of therapeutic ultrasound (US) therapy in the treatment of open wounds as an adjunct to the usual and customary treatment provided by physical therapists. An exhaustive search of all published studies on the effects of therapeutic ultrasound on open wounds was performed. Every article, which met certain criteria, was reviewed in detail. Criteria included the use of human subjects, animal subjects, or human cells in vitro, publication in referred journals indexed by MEDLINE, CINAHL and availability of full text in the English language. Fourteen studies met the selection criteria. A total of 31 possible outcomes were available from these studies. Outcomes were categorized as positive, negative or non-significant. The results indicated a total of seventeen positives, eight negatives and six non-significant outcomes. The results of the analysis indicate that there is evidence in the literature to suggest that therapeutic US is beneficial in the treatment of open wounds.
Resumo:
The impact of ultrasound on improving the performance of a granular iron Permeable Reactive Barrier (PRB) in the degradation of Trichloroethylene (TCE) was evaluated. Two treatment columns made of clear Plexiglas with a height of 1ft and a diameter of 2 inches and filled with granular iron were used. One was fitted with 25Khz ultrasound probes. A solution of TCE was run through at constant flow rate. Samples obtained from the column at different residence times before and after sonication were analyzed for concentrations of TCE and used to generate concentration profiles to obtain rate constants, which were compared. An improvement of 23.4% in the reaction rate of TCE degradation was observed after sonication of the iron media suggesting that ultrasound may contribute to improving the performance of PRBs in the degradation of TCE in contaminated groundwater.