3 resultados para trichloroethylene

em Digital Commons at Florida International University


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Permeable reactive barriers (PRB) are constructed from soil solid amendments to support the growth of bacteria that are capable of degrading organic contaminants. The objective of this study was to identify low-cost soil solid amendments that could retard the movement of trichloroethylene (TCE) while serving as long-lived carbon sources to foster its biodegradation in shallow groundwater through the use of a PRB. The natural amendments high in organic carbon content such as eucalyptus mulch, compost, wetland peat, organic humus were compared based on their geophysical characteristics, such as pHw, porosity and total organic carbon (TOC), and as well as TCE sorption potentials. The pHw values were within neutral range except for pine bark mulch and wetland peat. All other geophysical characteristics of the amendments showed suitability for use in a PRB. While the Freundlich model showed better fit for compost and pine bark mulch, the linear sorption model was adequate for eucalyptus mulch, wetland peat and Everglades muck within the concentration range studied (0.2-0.8 mg/L TCE). According to these results, two composts and eucalyptus mulch were selected for laboratory column experiments to evaluate their effectiveness at creating and maintaining conditions suitable for TCE anaerobic dechlorination. The columns were monitored for pH, ORP, TCE degradation, longevity of nutrients and soluble TOC to support TCE dechlorination. Native bacteria in the columns had the ability to convert TCE to DCEs; however, the inoculation with the TCE-degrading culture greatly increased the rate of biodegradation. This caused a significant increase in by-product concentration, mostly in the form of DCEs and VC followed by a slow degradation to ethylene. Of the tested amendments eucalyptus mulch was the most effective at supporting the TCE dechlorination. The experimental results of TCE sequential dechlorination took place in eucalyptus mulch and commercial compost from Savannah River Site columns were then simulated using the Hydrus-1D model. The simulations showed good fit with the experimental data. The results suggested that sorption and degradation were the dominant fate and transport mechanisms for TCE and DCEs in the column, supporting the use of these amendments in a permeable reactive barrier to remediate the TCE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of ultrasound on improving the performance of a granular iron Permeable Reactive Barrier (PRB) in the degradation of Trichloroethylene (TCE) was evaluated. Two treatment columns made of clear Plexiglas with a height of 1ft and a diameter of 2 inches and filled with granular iron were used. One was fitted with 25Khz ultrasound probes. A solution of TCE was run through at constant flow rate. Samples obtained from the column at different residence times before and after sonication were analyzed for concentrations of TCE and used to generate concentration profiles to obtain rate constants, which were compared. An improvement of 23.4% in the reaction rate of TCE degradation was observed after sonication of the iron media suggesting that ultrasound may contribute to improving the performance of PRBs in the degradation of TCE in contaminated groundwater.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Intoxilyzer 5000 was tested for calibration curve linearity for ethanol vapor concentration between 0.020 and 0.400g/210L with excellent linearity. Calibration error using reference solutions outside of the allowed concentration range, response to the same ethanol reference solution at different temperatures between 34 and 38$\sp\circ$C, and its response to eleven chemicals, 10 mixtures of two at the time, and one mixture of four chemicals potentially found in human breath have been evaluated. Potential interferents were chosen on the basis of their infrared signatures and the concentration range of solutions corresponding to the non-lethal blood concentration range of various volatile organic compounds reported in the literature. The result of this study indicates that the instrument calibrates with solutions outside the allowed range up to $\pm$10% of target value. Headspace FID dual column GC analysis was used to confirm the concentrations of the solutions. Increasing the temperature of the reference solution from 34 to 38$\sp\circ$C resulted in linear increases in instrument recorded ethanol readings with an average increase of 6.25%/$\sp\circ$C. Of the eleven chemicals studied during this experiment, six, isopropanol, toluene, methyl ethyl ketone, trichloroethylene, acetaldehyde, and methanol could reasonably interfere with the test at non-lethal reported blood concentration ranges, the mixtures of those six chemicals showed linear additive results with a combined effect of as much as a 0.080g/210L reading (Florida's legal limit) without any ethanol present. ^