3 resultados para non-radial efficiency
em Digital Commons at Florida International University
Resumo:
This dissertation analyzes hospital efficiency using various econometric techniques. The first essay provides additional and recent evidence to the presence of contract management behavior in the U.S. hospital industry. Unlike previous studies, which focus on either an input-demand equation or the cost function of the firm, this paper estimates the two jointly using a system of nonlinear equations. Moreover, it addresses the longitudinal problem of institutions adopting contract management in different years, by creating a matched control group of non-adopters with the same longitudinal distribution as the group under study. The estimation procedure then finds that labor, and not capital, is the preferred input in U.S. hospitals regardless of managerial contract status. With institutions that adopt contract management benefiting from lower labor inefficiencies than the simulated non-contract adopters. These results suggest that while there is a propensity for expense preference behavior towards the labor input, contract managed firms are able to introduce efficiencies over conventional, owner controlled, firms. Using data for the years 1998 through 2007, the second essay investigates the production technology and cost efficiency faced by Florida hospitals. A stochastic frontier multiproduct cost function is estimated in order to test for economies of scale, economies of scope, and relative cost efficiencies. The results suggest that small-sized hospitals experience economies of scale, while large and medium sized institutions do not. The empirical findings show that Florida hospitals enjoy significant scope economies, regardless of size. Lastly, the evidence suggests that there is a link between hospital size and relative cost efficiency. The results of the study imply that state policy makers should be focused on increasing hospital scale for smaller institutions while facilitating the expansion of multiproduct production for larger hospitals. The third and final essay employs a two staged approach in analyzing the efficiency of hospitals in the state of Florida. In the first stage, the Banker, Charnes, and Cooper model of Data Envelopment Analysis is employed in order to derive overall technical efficiency scores for each non-specialty hospital in the state. Additionally, input slacks are calculated and reported in order to identify the factors of production that each hospital may be over utilizing. In the second stage, we employ a Tobit regression model in order to analyze the effects a number of structural, managerial, and environmental factors may have on a hospital’s efficiency. The results indicated that most non-specialty hospitals in the state are operating away from the efficient production frontier. The results also indicate that the structural make up, managerial choices, and level of competition Florida hospitals face have an impact on their overall technical efficiency.
Resumo:
The growing need for fast sampling of explosives in high throughput areas has increased the demand for improved technology for the trace detection of illicit compounds. Detection of the volatiles associated with the presence of the illicit compounds offer a different approach for sensitive trace detection of these compounds without increasing the false positive alarm rate. This study evaluated the performance of non-contact sampling and detection systems using statistical analysis through the construction of Receiver Operating Characteristic (ROC) curves in real-world scenarios for the detection of volatiles in the headspace of smokeless powder, used as the model system for generalizing explosives detection. A novel sorbent coated disk coined planar solid phase microextraction (PSPME) was previously used for rapid, non-contact sampling of the headspace containers. The limits of detection for the PSPME coupled to IMS detection was determined to be 0.5-24 ng for vapor sampling of volatile chemical compounds associated with illicit compounds and demonstrated an extraction efficiency of three times greater than other commercially available substrates, retaining >50% of the analyte after 30 minutes sampling of an analyte spike in comparison to a non-detect for the unmodified filters. Both static and dynamic PSPME sampling was used coupled with two ion mobility spectrometer (IMS) detection systems in which 10-500 mg quantities of smokeless powders were detected within 5-10 minutes of static sampling and 1 minute of dynamic sampling time in 1-45 L closed systems, resulting in faster sampling and analysis times in comparison to conventional solid phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) analysis. Similar real-world scenarios were sampled in low and high clutter environments with zero false positive rates. Excellent PSPME-IMS detection of the volatile analytes were visualized from the ROC curves, resulting with areas under the curves (AUC) of 0.85-1.0 and 0.81-1.0 for portable and bench-top IMS systems, respectively. Construction of ROC curves were also developed for SPME-GC-MS resulting with AUC of 0.95-1.0, comparable with PSPME-IMS detection. The PSPME-IMS technique provides less false positive results for non-contact vapor sampling, cutting the cost and providing an effective sampling and detection needed in high-throughput scenarios, resulting in similar performance in comparison to well-established techniques with the added advantage of fast detection in the field.
Resumo:
By using near infrared spectroscopy (NIRS) and by modifying the current Somanetics® optodes being used with the INVOS oximeter, the modified optodes are made to be fairly functional not only across the forehead, but across the hairy regions of the scalp as well. A major problem arises in the positioning of these optodes on the patients scalp and holding them in place while recording data. Another problem arises in the inconsistent repeatability of the trends displayed in the recorded data. A method was developed to facilitate the easy placement of these optodes on the patients scalp keeping in mind thepatient's comfort. The sensitivity of the optodes, too, was improved by incorporating better refined techniques for manufacturing the fiber optic brushes and fixing the same to the optode transmitting and receiving windows. The modified and improved optodes, in the single as well as in the multiplexed modes, were subjected to various tests on different areas of the brain to determine their efficiency and functionality.