2 resultados para Supine
em Digital Commons at Florida International University
Resumo:
This study investigated the effect of sleep position on breathing patterns of normal full term infants during quiet and active behavioral sleep states. Tidal volume, percent contribution of rib cage to tidal volume, and respiration rate were measured via respiratory inductive plethysmography (RIP) and pneumotachograph (PNT) in ten infants sleeping in supine versus right side-lying. Data was collected immediately following two consecutive feedings. Paired t tests and ANOVA comparisons showed no significant differences between the two postures (p $<$.05) in mean tidal volume (supine, M = 19.16, right side, M = 22.45), percent contribution of rib cage to tidal volume (supine, M = 30.55, right side M = 33.20), or respiration rate (supine, M = 49.13, right side, M = 49.37) during quiet sleep. Comparisons also showed no significant differences between the two postures (p $<$.05) in mean tidal volume (supine, M = 18.89, right side, M = 20.12), percent contribution of rib cage to tidal volume (supine, M = 6.43, right side, M = 6.97) or respiration rate (supine, M = 62.18, right side, M = 61.04) during active sleep. Therefore, no differences were found in the three respiratory variables measured between the supine and right side-lying positions. These findings suggest that infants may be positioned in either sleep position without detriment to respiratory function. This information may benefit occupational therapists and other health professionals involved in the education of parents on infant positioning and their respective advantages. ^
Resumo:
Objective: Establish intra- and inter-examiner reliability of glenohumeral range of motion (ROM) measures taken by a single-clinician using a mechanical inclinometer. Design: A single-session, repeated-measure, randomized, counterbalanced design. Setting: Athletic Training laboratory. Participants: Ten college-aged volunteers (9 right-hand dominant; 4 males, 6 females; age=23.2±2.4y, mass=73±16kg, height=170±8cm) without shoulder or neck injuries within one year. Interventions: Two Certified Athletic Trainers separately assessed passive glenohumeral (GH) internal (IR) and external (ER) rotation bilaterally. Each clinician secured the inclinometer to each subject’s distal forearm using elastic straps. Clinicians followed standard procedures for assessing ROM, with the participants supine on a standard treatment table with 90° of elbow flexion. A second investigator recorded the angle. Clinicians measured all shoulders once to assess inter-clinician reliability and eight shoulders twice to assess intra-clinician reliability. We used SPSS 14.0 (SPSS Inc., Chicago, IL) to calculate standard error of measure (SEM) and Intraclass Correlation Coefficients (ICC) to evaluate intra- and inter-clinician reliability. Main Outcome Measures: Dependent variables were degrees of IR, ER, glenohumeral internal rotation deficit (GIRD) and total arc of rotation. We calculated GIRD as the bilateral difference in IR (nondominant–dominant) and total arc for each shoulder (IR+ER). Results: Intra-clinician reliability for each examiner was excellent (ICC[1,1] range=0.90-0.96; SEM=2.2°-2.5°) for all measures. Examiners displayed excellent inter-clinician reliability (ICC[2,1] range=0.79-0.97; SEM=1.7°-3.0°) for all measures except nondominant IR which had good reliability(0.72). Conclusions: Results suggest that clinicians can achieve reliable measures of GH rotation and GIRD using a single-clinician technique and an inexpensive, readily available mechanical inclinometer.