6 resultados para Sports facilities -- Heating and ventilation
em Digital Commons at Florida International University
Resumo:
Political leaders in urban settings regularly confront difficult decisions over how to distribute public funds. Those decisions may be even more controversial when they involve public subsidies of professional sports facilities. Yet, state and local governments in the United States have granted billions of dollars in financial and land-based subsidies for professional sports facilities over the past two decades, raising questions about how these types of corporate welfare decisions are made by local leaders. Scholarship on urban politics and community power suggests a number of theories to explain political influence. They include elitism, pluralism, political economy and growth machines, urban regimes, coalition theory, and minority empowerment. My hypothesis is that coalition theory, a theory that argues that public policy decisions are made by shifting, ad hoc alliances within a community, best describes these subsidy decisions. ^ To test this hypothesis I employ a public policy process model and develop a framework of variables that is used to methodically examine four sports facilities funding decisions in two Florida counties between 1977 and 1998: Joe Robbie Stadium and the American Airlines Arena in Miami-Dade, and the Ice Palace Arena and the Raymond James Stadium in Hillsborough County. The framework includes six variables that permit a rigorous examination of the actors involved in the decision, their interactions, and the political environment within which they operate. The variables are formal political structure, informal sector, subsidy proponents, subsidy opponents, public policy options, and public opinion. ^ This research rests on qualitative data gathered from interviews of public and private officials involved in subsidy decisions, public records, and media reports Employing a case study analysis, I offer a rich description of the decision making process to publicly fund sports stadiums and arenas in Florida. My findings confirm that the best theory to explain decisions to subsidize sports facilities is one in which short-term, temporary coalitions are formed to accomplish policy goals. ^
Resumo:
A novel biocompatible and biodegradable polymer, termed poly(Glycerol malate co-dodecanedioate) (PGMD), was prepared by thermal condensation method and used for fabrication of nanoparticles (NPs). PGMD NPs were prepared using the single oil emulsion technique and loaded with an imaging/hyperthermia agent (IR820) and a chemotherapeutic agent (doxorubicin, DOX). The size of the void PGMD NPs, IR820-PGMD NPs and DOX-IR820-PGMD NPs were approximately 90 nm, 110 nm, and 125 nm respectively. An acidic environment (pH=5.0) induced higher DOX and IR820 release compared to pH=7.4. DOX release was also enhanced by exposure to laser, which increased the temperature to 42°C. Cytotoxicity of DOX-IR820-PGMD NPs was comparable in MES-SA but was higher in Dx5 cells compared to free DOX plus IR820 (p<0.05). The combination of hyperthermia (HT) and chemotherapy improved cytotoxicity in both cell lines. We also explored the cellular response after rapid, short-term and low thermal dose (laser/Dye/NP) induced-heating, and compared it to slow, long-term and high thermal dose cell incubator heating by investigating the reactive oxygen species (ROS) level, hypoxia-inducible factor-1&agr; (HIF-1&agr;) and vascular endothelial growth factor (VEGF) expression. The cytotoxicity of IR820-PGMD NPs after laser/Dye/NP HT resulted in higher cancer cell killing compared to incubator HT. ROS level, HIF-1&agr; and VEGF expression were elevated under incubator HT, while maintained at the baseline level under the laser/Dye/NP HT. In vivo mouse studies showed that NP formulation significantly improved the plasma half-life of IR820 after tail vein injection. Significant lower IR820 content was observed in kidney in DOX-IR820-PGMD NP treatment as compared to free IR820 treatment in our biodistribution studies (p<0.05). In conclusion, both IR820-PGMD NPs and DOX-IR820-PGMD NPs were successfully developed and used for both imaging and therapeutic purposes. Rapid and short-term laser/Dye/NP HT, with a low thermal dose, did not up-regulate HIF-1&agr; and VEGF expression, whereas slow and long-term incubator HT, with a high thermal dose, can enhance expression of both HIF-1&agr; and VEGF.^
Resumo:
The purpose of this study was to test 3 hypotheses: (a) that late Miocene to early Pliocene constriction and complete closure of the Central American Seaway (CAS), connecting tropical Atlantic and East Equatorial Pacific (EEP) oceans, caused decreased productivity in the Caribbean, due to reduced coastal upwelling and an end to the connection with high-productivity Pacific waters, (b) reduced paleoproductivity resulted in decreased diversity in the Caribbean and, (c) this decreased availability of food (reduced paleoproductivity) was responsible for larger mean test size in the three most common benthic foraminiferal species Epistominella exigua, Oridorsalis umbonatus and Globocassidulina subglobosa. ^ These are tested by applying correlation analysis to 7 groups of paleoceanographic proxies, 3 indices of diversity measures and mean test size data from the Caribbean Ocean Drilling Project Site 999, to 47 core samples for the interval between 8.3-2.5 Ma. Results are compared with published Caribbean and Pacific deep-sea records. ^ The Caribbean, between 8.3-7.9 Ma, experienced reduced current velocity and lower ventilation of bottom waters. Thereafter, until 4.2 Ma, the seasonality of phytodetritus input increased and ventilation further reduced. From 4.2-2.5 Ma, paleoproductivity decreased, current velocity reduced, ventilation improved, and the seasonality of phytodetrital input decreased dramatically. The benthic foraminiferal diversity followed the same trend as paleoproductivity. Individual correlation analysis between mean test size of benthic foraminiferal species Epistominella exigua, Oridorsalis umbonatus and Globocassidulina subglobosa and paleoceanographic proxies yielded a positive and significant relationship with paleoproductivity. However, a combined datasets of all 3 species yielded a negative and significant relationship with species abundance. ^ Thus, the study concludes that (a) the gradual closure of the CAS led Caribbean diversity and paleoproductivity to decrease abruptly at 7.9 Ma, when the nutrient-rich Pacific deep waters were cut off, and then, again with the complete closure of the seaway at 4.2 Ma, (b) diversity and paleoproductivity are positively correlated in the Caribbean and (c) that the availability of food is an overriding factor that influences mean test size; lower availability of food and decreased abundance leads to larger test size. ^
Resumo:
The need for efficient, sustainable, and planned utilization of resources is ever more critical. In the U.S. alone, buildings consume 34.8 Quadrillion (1015) BTU of energy annually at a cost of $1.4 Trillion. Of this energy 58% is utilized for heating and air conditioning. ^ Several building energy analysis tools have been developed to assess energy demands and lifecycle energy costs in buildings. Such analyses are also essential for an efficient HVAC design that overcomes the pitfalls of an under/over-designed system. DOE-2 is among the most widely known full building energy analysis models. It also constitutes the simulation engine of other prominent software such as eQUEST, EnergyPro, PowerDOE. Therefore, it is essential that DOE-2 energy simulations be characterized by high accuracy. ^ Infiltration is an uncontrolled process through which outside air leaks into a building. Studies have estimated infiltration to account for up to 50% of a building's energy demand. This, considered alongside the annual cost of buildings energy consumption, reveals the costs of air infiltration. It also stresses the need that prominent building energy simulation engines accurately account for its impact. ^ In this research the relative accuracy of current air infiltration calculation methods is evaluated against an intricate Multiphysics Hygrothermal CFD building envelope analysis. The full-scale CFD analysis is based on a meticulous representation of cracking in building envelopes and on real-life conditions. The research found that even the most advanced current infiltration methods, including in DOE-2, are at up to 96.13% relative error versus CFD analysis. ^ An Enhanced Model for Combined Heat and Air Infiltration Simulation was developed. The model resulted in 91.6% improvement in relative accuracy over current models. It reduces error versus CFD analysis to less than 4.5% while requiring less than 1% of the time required for such a complex hygrothermal analysis. The algorithm used in our model was demonstrated to be easy to integrate into DOE-2 and other engines as a standalone method for evaluating infiltration heat loads. This will vastly increase the accuracy of such simulation engines while maintaining their speed and ease of use characteristics that make them very widely used in building design.^
Resumo:
The need for efficient, sustainable, and planned utilization of resources is ever more critical. In the U.S. alone, buildings consume 34.8 Quadrillion (1015) BTU of energy annually at a cost of $1.4 Trillion. Of this energy 58% is utilized for heating and air conditioning. Several building energy analysis tools have been developed to assess energy demands and lifecycle energy costs in buildings. Such analyses are also essential for an efficient HVAC design that overcomes the pitfalls of an under/over-designed system. DOE-2 is among the most widely known full building energy analysis models. It also constitutes the simulation engine of other prominent software such as eQUEST, EnergyPro, PowerDOE. Therefore, it is essential that DOE-2 energy simulations be characterized by high accuracy. Infiltration is an uncontrolled process through which outside air leaks into a building. Studies have estimated infiltration to account for up to 50% of a building’s energy demand. This, considered alongside the annual cost of buildings energy consumption, reveals the costs of air infiltration. It also stresses the need that prominent building energy simulation engines accurately account for its impact. In this research the relative accuracy of current air infiltration calculation methods is evaluated against an intricate Multiphysics Hygrothermal CFD building envelope analysis. The full-scale CFD analysis is based on a meticulous representation of cracking in building envelopes and on real-life conditions. The research found that even the most advanced current infiltration methods, including in DOE-2, are at up to 96.13% relative error versus CFD analysis. An Enhanced Model for Combined Heat and Air Infiltration Simulation was developed. The model resulted in 91.6% improvement in relative accuracy over current models. It reduces error versus CFD analysis to less than 4.5% while requiring less than 1% of the time required for such a complex hygrothermal analysis. The algorithm used in our model was demonstrated to be easy to integrate into DOE-2 and other engines as a standalone method for evaluating infiltration heat loads. This will vastly increase the accuracy of such simulation engines while maintaining their speed and ease of use characteristics that make them very widely used in building design.