2 resultados para SCHOTTKY PHOTODIODES
em Digital Commons at Florida International University
Resumo:
To perform daily flight tasks, insects rely heavily on their visual perception of a dynamic environment. They must process visual signals quickly and accurately and update their behavior. Flies are vulnerable to environmental disturbances, such as gusts of wind blowing them off course, but they may use the altered visual field to compensate and regain their original course. In studies using Drosophila melanogaster, it has been shown that their corrective responses can be analyzed by measuring changes in their wing beats. By enclosing a tethered fly in a cuboidal visual arena displaying a computerized optic flow field, it is possible to calculate the change in wing beat amplitudes from an infrared shadow of its wings using photodiodes and a custom wing beat analyzer. In this experiment, manipulations ofthe optic flow field are used to create a field where points have varying relative forward speed, to study how the insect performs corrective maneuvers. The results show that Drosophila have a stronger corrective response to the quickly moving, apparently near points compared to the slower moving, apparently distant points. This implies the flies are distinguishing points based on their relative speeds, inferring distance, and adjusting their corrective actions with this information.
Resumo:
The problems to be solved in this thesis were 1) development of a broadband RF preamplifier to be used with non-ferrous current probes so that the amplified signal exceeds the errors due to cable pickup, no detection is needed in this application, and 2) development of a self-contained device that amplifies and detects the output from a nonferrous current probe, providing a digital readout of the current. These instruments have been completed and are being tested for use by the National Institutes of Occupational Safety and Health (NIOSH). The self-contained current meter operates at frequencies up to 600 MHz, and detects currents as low as 8 mA . At these current magnitudes, the probe (pick-up coil) will output a voltage of 500μV (-53 dBm on 50Ω) which will have to be raised above 0 dBm. The final circuit uses a RF mixer as a variable attenuator in order to increase the dynamic range, two Monolithic Microwave Integrated Circuits (MMIC) for preamplification, a final broadband amplifier to raise the output compression point, a Schottky diode detector, a sample and hold circuit, and a liquid crystal digital panel meter.