3 resultados para Quasi-stationary approach

em Digital Commons at Florida International University


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Intraoperative neurophysiologic monitoring is an integral part of spinal surgeries and involves the recording of somatosensory evoked potentials (SSEP). However, clinical application of IONM still requires anywhere between 200 to 2000 trials to obtain an SSEP signal, which is excessive and introduces a significant delay during surgery to detect a possible neurological damage. The aim of this study is to develop a means to obtain the SSEP using a much less, twelve number of recordings. The preliminary step involved was to distinguish the SSEP with the ongoing brain activity. We first establish that the brain activity is indeed quasi-stationary whereas an SSEP is expected to be identical every time a trial is recorded. An algorithm was developed using Chebychev time windowing for preconditioning of SSEP trials to retain the morphological characteristics of somatosensory evoked potentials (SSEP). This preconditioning was followed by the application of a principal component analysis (PCA)-based algorithm utilizing quasi-stationarity of EEG on 12 preconditioned trials. A unique Walsh transform operation was then used to identify the position of the SSEP event. An alarm is raised when there is a 10% time in latency deviation and/or 50% peak-to-peak amplitude deviation, as per the clinical requirements. The algorithm shows consistency in the results in monitoring SSEP in up to 6-hour surgical procedures even under this significantly reduced number of trials. In this study, the analysis was performed on the data recorded in 29 patients undergoing surgery during which the posterior tibial nerve was stimulated and SSEP response was recorded from scalp. This method is shown empirically to be more clinically viable than present day approaches. In all 29 cases, the algorithm takes 4sec to extract an SSEP signal, as compared to conventional methods, which take several minutes. The monitoring process using the algorithm was successful and proved conclusive under the clinical constraints throughout the different surgical procedures with an accuracy of 91.5%. Higher accuracy and faster execution time, observed in the present study, in determining the SSEP signals provide a much improved and effective neurophysiological monitoring process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectionable odors remain at the top of air pollution complaints in urban areas such as Broward County that is subject to increasing residential and industrial developments. The odor complaints in Broward County escalated by 150 percent for the 2001 to 2004 period although the population increased by only 6 percent. It is estimated that in 2010 the population will increase to 2.5 million. Relying solely on enforcing the local odor ordinance is evidently not sufficient to manage the escalating odor complaint trends. An alternate approach similar to odor management plans (OMPs) that are successful in managing major malodor sources such as animal farms is required. ^ This study aims to develop and determine the feasibility of implementing a comprehensive odor management plan (COMP) for the entire Broward County. Unlike existing OMPs for single sources where the receptors (i.e. the complainants) are located beyond the boundary of the source, the COMP addresses a complex model of multiple sources and receptors coexisting within the boundary of the entire county. Each receptor is potentially subjected to malodor emissions from multiple sources within the county. Also, the quantity and quality of the source/receptor variables are continuously changing. ^ The results of this study show that it is feasible to develop a COMP that adopts a systematic procedure to: (1) Generate maps of existing odor complaint areas and malodor sources, (2) Identify potential odor sources (target sources) responsible for existing odor complaints, (3) Identify possible odor control strategies for target sources, (4) Determine the criteria for implementing odor control strategies, (5) Develop an odor complaint response protocol, and (6) Conduct odor impact analyses for new sources to prevent future odor related issues. Geographic Information System (GIS) is used to identify existing complaint areas. A COMP software that incorporates existing United States Environmental Protection Agency (EPA) air dispersion software is developed to determine the target sources, predict the likelihood of new complaints, and conduct odor impact analysis. The odor response protocol requires pre-planning field investigations and conducting surveys to optimize the local agency available resources while protecting the citizen's welfare, as required by the Clean Air Act. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: In this study, quasi-three-dimensional (3D) microwell patterns were fabricated with poly (l-lactic acid) for the development of cell-based assays, targeting voltage-gated calcium channels (VGCCs). Methods and materials: SH-SY5Y human neuroblastoma cells were interfaced with the microwell patterns and found to grow as two dimensional (2D), 3D, and near two dimensional (N2D), categorized on the basis of the cells’ location in the pattern. The capability of the microwell patterns to support 3D cell growth was evaluated in terms of the percentage of the cells in each growth category. Cell spreading was analyzed in terms of projection areas under light microscopy. SH-SY5Y cells’ VGCC responsiveness was evaluated with confocal microscopy and a calcium fluorescent indicator, Calcium GreenTM-1. The expression of L-type calcium channels was evaluated using immunofluorescence staining with DM-BODIPY. Results: It was found that cells within the microwells, either N2D or 3D, showed more rounded shapes and less projection areas than 2D cells on flat poly (l-lactic acid) substrates. Also, cells in microwells showed a significantly lower VGCC responsiveness than cells on flat substrates, in terms of both response magnitudes and percentages of responsive cells, upon depolarization with 50 mM K+. This lower VGCC responsiveness could not be explained by the difference in L-type calcium channel expression. For the two patterns addressed in this study, N2D cells consistently exhibited an intermediate value of either projection areas or VGCC responsiveness between those for 2D and 3D cells, suggesting a correlative relation between cell morphology and VGCC responsiveness. Conclusion: These results suggest that the pattern structure and therefore the cell growth characteristics were critical factors in determining cell VGCC responsiveness and thus provide an approach for engineering cell functionality in cell-based assay systems and tissue engineering scaffolds.