10 resultados para INTRUSIVE LUXATION
em Digital Commons at Florida International University
Resumo:
This study investigated how intrusive noises affect local university students in their communities. The Community Noise Survey solicited information about types of bothersome noises, how often these noises were bothersome, activities intruded upon by these noises, feelings elicited by noise intrusions, and what participants did to abate the noises.
Resumo:
As long as governmental institutions have existed, efforts have been undertaken to reform them. This research examines a particular strategy, coercive controls, exercised through a particular instrument, executive orders, by a singular reformer, the president of the United States. The presidents studied-- Johnson, Nixon, Ford, Carter, Reagan, Bush, and Clinton--are those whose campaigns for office were characterized to varying degrees as against Washington bureaucracy and for executive reform. Executive order issuance is assessed through an examination of key factors for each president including political party affiliation, levels of political capital, and legislative experience. A classification typology is used to identify the topical dimensions and levels of coerciveness. The portrayal of the federal government is analyzed through examination of public, media, and presidential attention. The results show that executive orders are significant management tools for the president. Executive orders also represent an important component of the transition plans for incoming administrations. The findings indicate that overall, while executive orders have not increased in the aggregate, they are more intrusive and significant. When the factors of political party affiliation, political capital, and legislative experience are examined, it reveals a strong relationship between executive orders and previous executive experience, specifically presidents who served as a state governor prior to winning national election as president. Presidents Carter, Reagan, and Clinton (all former governors) have the highest percent of executive orders focusing on the federal bureaucracy. Additionally, the highest percent of forceful orders were issued by former governors (41.0%) as compared to their presidential counterparts who have not served as governors (19.9%). Secondly, political party affiliation is an important, but not significant, predictor for the use of executive orders. Thirdly, management strategies that provide the president with the greatest level of autonomy--executive orders--redefine the concept of presidential power and autonomous action. Interviews of elite government officials and political observers support the idea that executive orders can provide the president with a successful management strategy, requiring less expenditure of political resources, less risk to political capital, and a way of achieving objectives without depending on an unresponsive Congress. ^
Resumo:
Lavas belonging to the Grande Ronde Formation (GRB) constitute about 63% of the Columbia River Basalt Group (CRBG), a flood basalt province in the NW United States. A puzzling feature is the lack of phenocrysts (< 5%) in these chemically evolved lavas. Based mainly on this observation it has been hypothesized that GRB lavas were nearly primary melts generated by large-scale melting of eclogite. Another recent hypothesis holds that GRB magmas were extremely hydrous and rose rapidly from the mantle such that the dissolved water kept the magmas close to their liquidi. I present new textural and chemical evidence to show that GRB lavas were neither primary nor hydrous melts but were derived from other melts via efficient fractional crystallization and mixing in shallow intrusive systems. Texture and chemical features further suggest that the melt mixing process may have been exothermic, which forced variable melting of some of the existing phenocrysts. ^ Finally, reported here are the results of efforts to simulate the higher pressure histories of GRB using COMAGMAT and MELTS softwares. The intent was to evaluate (1) whether such melts could be derived from primary melts formed by partial melting of a peridotite source as an alternative to the eclogite model, or if bulk melting of eclogite is required; and (2) at what pressure such primary melts could have been in equilibrium with the mantle. I carried out both forward and inverse modeling. The best fit forward model indicates that most primitive parent melts related to GRB could have been multiply saturated at ∼1.5--2.0 GPa. I interpret this result to indicate that the parental melts last equilibrated with a peridotitic mantle at 1.5--2.0 GPa and such partial melts rose to ∼0.2 GPa where they underwent efficient mixing and fractionation before erupting. These models suggest that the source rock was not eclogitic but a fertile spinel lherzolite, and that the melts had ∼0.5% water. ^
Resumo:
Damages during extreme wind events highlight the weaknesses of mechanical fasteners at the roof-to-wall connections in residential timber frame buildings. The allowable capacity of the metal fasteners is based on results of unidirectional component testing that do not simulate realistic tri-axial aerodynamic loading effects. The first objective of this research was to simulate hurricane effects and study hurricane-structure interaction at full-scale, facilitating better understanding of the combined impacts of wind, rain, and debris on inter-component connections at spatial and temporal scales. The second objective was to evaluate the performance of a non-intrusive roof-to-wall connection system using fiber reinforced polymer (FRP) materials and compare its load capacity to the capacity of an existing metal fastener under simulated aerodynamic loads. ^ The Wall of Wind (WoW) testing performed using FRP connections on a one-story gable-roof timber structure instrumented with a variety of sensors, was used to create a database on aerodynamic and aero-hydrodynamic loading on roof-to-wall connections tested under several parameters: angles of attack, wind-turbulence content, internal pressure conditions, with and without effects of rain. Based on the aerodynamic loading results obtained from WoW tests, sets of three force components (tri-axial mean loads) were combined into a series of resultant mean forces, which were used to test the FRP and metal connections in the structures laboratory up to failure. A new component testing system and test protocol were developed for testing fasteners under simulated triaxial loading as opposed to uni-axial loading. The tri-axial and uni-axial test results were compared for hurricane clips. Also, comparison was made between tri-axial load capacity of FRP and metal connections. ^ The research findings demonstrate that the FRP connection is a viable option for use in timber roof-to-wall connection system. Findings also confirm that current testing methods of mechanical fasteners tend to overestimate the actual load capacities of a connector. Additionally, the research also contributes to the development a new testing protocol for fasteners using tri-axial simultaneous loads based on the aerodynamic database obtained from the WoW testing. ^
Resumo:
A variety of world-class mineral deposits occur in Mesozoic and Tertiary rocks of the Guerrero terrane. New Pb isotope analyses of various crustal units and ores from distinct subterranes of the Guerrero terrane are presented to trace metal sources in these deposits and infer source reservoirs. New Sr and Nd isotope results are provided to gain insight into the provenance of the crustal rocks from the Guerrero terrane. Triassic schist samples from the Arteaga Complex and Triassic-Jurassic phyllite and slate samples from the Tejupilco metamorphic suite contain radiogenic Pb (206Pb/204Pb = 18.701–19.256) relative to bulk earth models. Cretaceous sedimentary rocks of the Zihuatanejo Sequence are more radiogenic (206Pb/204Pb = 18.763–19.437) than samples from the Huetamo Sequence (206Pb/204Pb = 18.630–18.998). Tertiary intrusive rocks from La Verde, Inguaran, La Esmeralda, and El Malacate plot to the right of the average Pb crust evolution curve of Stacey and Kramers (206Pb/204Pb = 18.705–19.033). Ores from the La Verde and La Esmeralda porphyry copper deposits yield isotopic ratios (206Pb/204Pb = 18.678–18.723) that are generally less radiogenic than the host igneous rocks, but plot within the field defined by the sedimentary rocks from the Huetamo Sequence. Tertiary intrusive rocks from the Zimapan and La Negra districts in the Sierra Madre terrane plot above and to the right of the Stacey-Kramers reference line (206Pb/204Pb = 18.804–18.972). Lead isotope ratios of ore minerals from the Zimapan and La Negra skarn mines ( 206Pb/204Pb = 18.775–18.975) resemble those of the associated igneous rocks, implying a magmatic Pb input in the skarn deposits. New Sr and Nd isotope data on metamorphic rocks (87Sr/ 86Sr = 0.707757–0.726494 and 143Nd/144 Nd = 0.512109–0.512653) suggest that the basement of the Guerrero terrane originated from sources that had been derived from an old cratonic area. The narrow ranges and generally low 87Sr/86Sr ratios (0.704860–0.705755) and 143Nd/144Nd values (0.512765–0.512772) above that of bulk earth for igneous rocks from Inguaran, El Malacate, and La Esmeralda suggest a relatively low degree of crustal contamination. However, the isotopic values for the La Verde site (87Sr/86Sr = 0.708784 and 143Nd/144Nd = 0.512640) may indicate the involvement of a more evolved crustal component.
Resumo:
Background: Obesity, a growing epidemic, is a preventable risk factor for cardiometabolic diseases. Obesity and cardiometabolic diseases affect Hispanics and African Americans more than non-Hispanic Caucasians. This study examined the relationship among race/ethnicity, obesity diagnostic measures (body mass index, waist circumference, subscapular and triceps skinfold thickness), and cardiometabolic risk factors (hyperglycemia, high, non-high-density lipoprotein cholesterol, low, high-density lipoprotein cholesterol, and hypertension) for adults across the United States. Methods: Using data from two-cycles of the National Health and Examination Survey (NHANES) 2007-2010, and accounting for the complex sample design, logistic regression models were conducted comparing obesity indicators in Mexican Americans, other Hispanics, and Black non-Hispanics, with White non-Hispanics and their associations with the presence of cardiometabolic diseases. Results: Differences by race/ethnicity were found for subscapular skinfold thickness and hyperglycemia. Waist circumference and subscapular skinfold were positively associated with the presence of hyperglycemia; dyslipidemia, and hypertension across race/ ethnicity, adjusting for age, gender, smoking, physical activity, education, income to poverty index, and health insurance. Race/ ethnicity did not influence the association of any obesity indicators with the tested cardiometabolic diseases. All obesity measures except triceps skinfold were associated with hyperglycemia. Conclusions: We suggest that subscapular skinfold thickness be considered as an inexpensive non-intrusive screening tool for cardiometabolic risk factors in an adult US population
Resumo:
Passive samplers are not only a versatile tool to integrate environmental concentrations of pollutants, but also to avoid the use of live sentinel organisms for environmental monitoring. This study introduced the use of magnetic silicone polymer composites (Fe-PDMS) as passive sampling media to pre-concentrate a wide range of analytes from environmental settings. The composite samplers were assessed for their accumulation properties by performing lab experiments with two model herbicides (Atrazine and Irgarol 1051) and evaluated for their uptake properties from environmental settings (waters and sediments). The Fe-PDMS composites showed good accumulation of herbicides and pesticides from both freshwater and saltwater settings and the accumulation mechanism was positively correlated with the log Kow value of individual analytes. Results from the studies show that these composites could be easily used for a wide number of applications such as monitoring, cleanup, and/or bioaccumulation modeling, and as a non-intrusive and nondestructive monitoring tool for environmental forensic purposes.
Resumo:
Damages during extreme wind events highlight the weaknesses of mechanical fasteners at the roof-to-wall connections in residential timber frame buildings. The allowable capacity of the metal fasteners is based on results of unidirectional component testing that do not simulate realistic tri-axial aerodynamic loading effects. The first objective of this research was to simulate hurricane effects and study hurricane-structure interaction at full-scale, facilitating better understanding of the combined impacts of wind, rain, and debris on inter-component connections at spatial and temporal scales. The second objective was to evaluate the performance of a non-intrusive roof-to-wall connection system using fiber reinforced polymer (FRP) materials and compare its load capacity to the capacity of an existing metal fastener under simulated aerodynamic loads. The Wall of Wind (WoW) testing performed using FRP connections on a one-story gable-roof timber structure instrumented with a variety of sensors, was used to create a database on aerodynamic and aero-hydrodynamic loading on roof-to-wall connections tested under several parameters: angles of attack, wind-turbulence content, internal pressure conditions, with and without effects of rain. Based on the aerodynamic loading results obtained from WoW tests, sets of three force components (tri-axial mean loads) were combined into a series of resultant mean forces, which were used to test the FRP and metal connections in the structures laboratory up to failure. A new component testing system and test protocol were developed for testing fasteners under simulated tri-axial loading as opposed to uni-axial loading. The tri-axial and uni-axial test results were compared for hurricane clips. Also, comparison was made between tri-axial load capacity of FRP and metal connections. The research findings demonstrate that the FRP connection is a viable option for use in timber roof-to-wall connection system. Findings also confirm that current testing methods of mechanical fasteners tend to overestimate the actual load capacities of a connector. Additionally, the research also contributes to the development a new testing protocol for fasteners using tri-axial simultaneous loads based on the aerodynamic database obtained from the WoW testing.
Resumo:
Implicit in current design practice of minimum uplift capacity, is the assumption that the connection's capacity is proportional to the number of fasteners per connection joint. This assumption may overestimate the capacity of joints by a factor of two or more and maybe the cause of connection failures in extreme wind events. The current research serves to modify the current practice by proposing a realistic relationship between the number of fasteners and the capacity of the joint. The research is also aimed at further development of non-intrusive continuous load path (CLP) connection system using Glass Fiber Reinforced Polymer (GFRP) and epoxy. Suitable designs were developed for stud to top plate and gable end connections and tests were performed to evaluate the ultimate load, creep and fatigue behavior. The objective was to determine the performance of the connections under simulated sustained hurricane conditions. The performance of the new connections was satisfactory.
Resumo:
As long as governmental institutions have existed, efforts have been undertaken to reform them. This research examines a particular strategy, coercive controls, exercised through a particular instrument, executive orders, by a singular reformer, the president of the United States. The presidents studied- Johnson, Nixon, Ford, Carter, Reagan, Bush, and Clinton-are those whose campaigns for office were characterized to varying degrees as against Washington bureaucracy and for executive reform. Executive order issuance is assessed through an examination of key factors for each president including political party affiliation, levels of political capital, and legislative experience. A classification typology is used to identify the topical dimensions and levels of coerciveness. The portrayal of the federal government is analyzed through examination of public, media, and presidential attention. The results show that executive orders are significant management tools for the president. Executive orders also represent an important component of the transition plans for incoming administrations. The findings indicate that overall, while executive orders have not increased in the aggregate, they are more intrusive and significant. When the factors of political party affiliation, political capital, and legislative experience are examined, it reveals a strong relationship between executive orders and previous executive experience, specifically presidents who served as a state governor prior to winning national election as president. Presidents Carter, Reagan, and Clinton (all former governors) have the highest percent of executive orders focusing on the federal bureaucracy. Additionally, the highest percent of forceful orders were issued by former governors (41.0%) as compared to their presidential counterparts who have not served as governors (19.9%). Secondly, political party affiliation is an important, but not significant, predictor for the use of executive orders. Thirdly, management strategies that provide the president with the greatest level of autonomy-executive orders redefine the concept of presidential power and autonomous action. Interviews of elite government officials and political observers support the idea that executive orders can provide the president with a successful management strategy, requiring less expenditure of political resources, less risk to political capital, and a way of achieving objectives without depending on an unresponsive Congress.