2 resultados para Hydroxybutyrate-hydroxyvalerate Copolymers
em Digital Commons at Florida International University
Resumo:
Fulgides and fulgimides are important organic photochromic compounds and can switch between the open forms and the closed forms with light. The 3-indolylfulgides and 3-indolylfulgimides exhibit promising photochromic properties and have great potential in optical memory devices, optical switches and biosensors. Copolymers containing 3-indolylfulgides/indolylfulgimides synthesized via free radical polymerizations increase conformation changes and allow the photochromic compounds to be uniformly distributed in the polymer matrix. A trifluoromethyl 3-indolylfulgide and two trifluoromethyl 3-indolylfulgimides with one or two polymerizable N-stryryl group(s) were prepared. Copolymerization with methyl methacrylate provided two linear copolymers or a cross-linked copolymer. The properties of the monomeric fulgide/fulgimides and copolymers in toluene or as thin films were characterized. In general, the photochromic monomers and copolymers revealed similar photochromic properties and exhibited good thermal and photochemical stability. All compounds absorb visible light in both open forms and closed forms. The closed form copolymers were more stable than the open form copolymers and showed little or no degradation after 400 h. The photochemical degradation rate was less than 0.03% per cycle. In films, conformational restrictions were observed for the open forms suggesting that the preparation of films from the closed forms is advantageous. Two novel methyl 3-indolylfulgimides with one or two polymerizable N-stryryl group(s) were prepared. Copolymerization of acrylamide with the methyl indolylfulgimides or the trifluoromethyl indolylfulgimides yielded two aqueous soluble linear copolymers and two photochromic hydrogels. The closed form copolymers containing trifluoromethyl indolylfulgimides were hydrolyzed in aqueous solution by replacing the trifluoromethyl group with a carboxylic acid group. The resulting carboxylic copolymers were also photochromic. The copolymers containing methyl fulgimides were stable in aqueous solutions and did not hydrolyze. Both methyl and carboxylic copolymers exhibited good stability in aqueous solutions. In general, the open form copolymers were more stable than the closed form copolymers, and the copolymers revealed better stability in acidic solution than neutral solution. The linear copolymers displayed better photochemical stability in neutral solution and degraded up to 22% after 105 cycles. In contrast, the hydrogels showed enhanced fatigue resistance in acidic condition and underwent up to 60 cycles before degrading 24%.
Resumo:
The drugs studied in this work have been reportedly used to commit drug-facilitated sexual assault (DFSA), commonly known as "date rape". Detection of the drugs was performed using high-performance liquid chromatography with ultraviolet detection (HPLC/UV) and identified with high performance-liquid chromatography mass spectrometry (HPLC/MS) using selected ion monitoring (SIM). The objective of this study was to develop a single HPLC method for the simultaneous detection, identification and quantitation of these drugs. The following drugs were simultaneously analyzed: Gamma-hydroxybutyrate (GHB), scopolamine, lysergic acid diethylamide, ketamine, flunitrazepam, and diphenhydramine. The results showed increased sensitivity with electrospray (ES) ionization versus atmospheric pressure chemical ionization (APCI) using HPLC/MS. HPLC/ES/MS was approximately six times more sensitive than HPLC/APCI/MS and about fifty times more sensitive than HPLC/UV. A limit of detection (LOD) of 100 ppb was achieved for drug analysis using this method. The average linear regression coefficient of correlation squared (r2) was 0.933 for HPLC/UV and 0.998 for HPLC/ES/MS. The detection limits achieved by this method allowed for the detection of drug dosages used in beverage tampering. This method can be used to screen beverages suspected of drug tampering. The results of this study demonstrated that solid phase microextraction (SPME) did not improve sensitivity as an extraction technique when compared to direct injections of the drug standards.