3 resultados para HIGH-PURITY GE DETECTORS

em Digital Commons at Florida International University


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Binary skutterudite CoSb3 nanoparticles were synthesized by solvothermal method. The nanostructuring of CoSb3 material was achieved by the inclusion of various kinds of additives. X-ray diffraction examination indicated the formation of the cubic phase of CoSb3. Structural analysis by transmission electron microscopy analysis further confirmed the formation of crystalline CoSb3 nanoparticles with high purity. With the assistance of additives, CoSb3nanoparticles with size as small as 10 nm were obtained. The effect of the nanostructure of CoSb3on the UV–visible absorption and luminescence was studied. The nanosized CoSb3 skutterudite may find application in developing thermoelectric devices with better efficiency. K

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Myocardial cell transplantation can compensate for the loss of necrotic cardiomyocytes. The objective of this research study was to reformulate the hydrogel with concentrations of growth factors, such as Leukemia Inhibitory Factor (LIF), Hepatocyte Growth Factor (HGF), and Interleukin-6 (IL-6). A controlled delivery system of PEO-PPO-PEO was formulated for release of a single growth factor and of multiple growth factors. Cytotoxicity and proliferation assay for single growth factors starting with 4000 skeletal myoblasts yielded their highest proliferation at 4 days with HGF (25,500 cells) and LIF (42,000 cells), while IL-6 (115,000 cells) generated its highest proliferation at 5 days. Combination of LIF and IL-6 resulted in highest proliferation at day 2 (220,000 cells), HGF and LIF (108,000 cells), and HGF and IL-6 (80,000 cells) both at 5 days. Viability at 37°C was maintained during the five days at 98-99%. The formulation was successful in myotube formation while maintaining a high purity of myoblasts in culture. The new formulation induced controlled release of growth factors and skeletal myoblasts delivery under favorable conditions while increasing the proliferation of myoblasts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Testing of summing electronics and VDC A/D Cards was performed to assure proper functioning and operation within defined parameters. In both the summing modules and the VDC A/D cards, testing for minimum threshold voltage for each channel and crosstalk between neighboring channels was performed. Additionally, the modules were installed in Hall A with input signals from shower detectors arranged to establish a trigger by summing signals together with the use of tested modules. Testing involved utilizing a pulser to mimic PMT signals, a discriminator, an attenuator, a scaler, a level translator, an oscilloscope, a high voltage power supply, and a special apparatus used to power and send signal to the A/D cards. After testing, modules were obtained that meet necessary criteria for use in the APEX experiment, and the A/D cards obtained were determined to have adequate specifications for their utilization, with specific results included in the appendix.