4 resultados para GC-FID

em Digital Commons at Florida International University


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Surfactant enhanced subsurface remediation has gained importance in soil remediation. Since surfactants can be sorbed on soils, the concentration of free surfactant could drop below the critical micelle concentration, CMC, which may reduce the ability of the surfactant to solubilize the contaminants in soils. ^ The main goal of this research was to study the factors affecting the surfactant sorption on soil such as surfactant concentration, soil organic content, and organic contaminants in soil and to determine the organic contaminants removed from soils by surfactant. The results would be served as the basis for the implementation of a future study in the pilot scale and field scale for surfactant enhanced subsurface remediation. ^ This research study investigated the relationship between the organic content of soils and the sorption characteristics of a nonionic surfactant, Triton X-100. The experiments were performed using uncontaminated soils and soil contaminated with naphthalene and decane. The first part of the experiments were conducted in batch mode utilizing surface tension technique to determine the CMC of surfactant Triton X-100 and the effective CMC in the soil/aqueous system. The sorption of Triton X-100 was calculated from the surface tension measurements. The second part of the experiments utilized the SPME/GC/FID technique to determine the concentration of the contaminants solubilized from the soils by the surfactant Triton X-100 at different concentrations. ^ The results indicated that when the concentration of surfactant was lower than the CMC, the amount of surfactant sorbed on soil increased with the increasing surfactant concentration and the surfactant sorption characteristics of the uncontaminated soils could be modeled by the Freundlich isotherm. For the contaminated soils, the amount of surfactant sorbed was higher than those for the uncontaminated soils. The amount of surfactant sorbed on soils also depends on the organic content in the soils. The higher the organic content in the soil, higher is the amount of surfactant sorbed onto the soil. When the concentration of surfactant was higher than the CMC, the amount of surfactant added into the soil/aqueous system will increase the number of micelle and it increase the solubilization of organic contaminant from the soils. The ratio of the moles of organic contaminant solubilized to the moles of surfactant present as micelles is called the molar solubilization ratio (MSR). MSR value for naphthalene was about 0.16 for the soil-water systems. The organic content of soil did not appear to affect MSR for naphthalene. On the other hand, the MSR values for decane were 0.52, 0.39 and 0.38 for soils with 25%, 50% and 75% organic content, respectively. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Intoxilyzer 5000 was tested for calibration curve linearity for ethanol vapor concentration between 0.020 and 0.400g/210L with excellent linearity. Calibration error using reference solutions outside of the allowed concentration range, response to the same ethanol reference solution at different temperatures between 34 and 38$\sp\circ$C, and its response to eleven chemicals, 10 mixtures of two at the time, and one mixture of four chemicals potentially found in human breath have been evaluated. Potential interferents were chosen on the basis of their infrared signatures and the concentration range of solutions corresponding to the non-lethal blood concentration range of various volatile organic compounds reported in the literature. The result of this study indicates that the instrument calibrates with solutions outside the allowed range up to $\pm$10% of target value. Headspace FID dual column GC analysis was used to confirm the concentrations of the solutions. Increasing the temperature of the reference solution from 34 to 38$\sp\circ$C resulted in linear increases in instrument recorded ethanol readings with an average increase of 6.25%/$\sp\circ$C. Of the eleven chemicals studied during this experiment, six, isopropanol, toluene, methyl ethyl ketone, trichloroethylene, acetaldehyde, and methanol could reasonably interfere with the test at non-lethal reported blood concentration ranges, the mixtures of those six chemicals showed linear additive results with a combined effect of as much as a 0.080g/210L reading (Florida's legal limit) without any ethanol present. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

2011-12 Worlds Ahead Strategic Plan Implementation Meeting held at Graham Center, Modesto Maidique Campus. Speakers included President Mark B. Rosenberg, Provost and Executive Vice President for Academic Affairs Douglas Wartzok,

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gunshot residue (GSR) is the term used to describe the particles originating from different parts of the firearm and ammunition during the discharge. A fast and practical field tool to detect the presence of GSR can assist law enforcement in the accurate identification of subjects. A novel field sampling device is presented for the first time for the fast detection and quantitation of volatile organic compounds (VOCs). The capillary microextraction of volatiles (CMV) is a headspace sampling technique that provides fast results (< 2 min. sampling time) and is reported as a versatile and high-efficiency sampling tool. The CMV device can be coupled to a Gas Chromatography-Mass Spectrometry (GC-MS) instrument by installation of a thermal separation probe in the injection port of the GC. An analytical method using the CMV device was developed for the detection of 17 compounds commonly found in polluted environments. The acceptability of the CMV as a field sampling method for the detection of VOCs is demonstrated by following the criteria established by the Environmental Protection Agency (EPA) compendium method TO-17. The CMV device was used, for the first time, for the detection of VOCs on swabs from the hands of shooters, and non-shooters and spent cartridges from different types of ammunition (i.e., pistol, rifle, and shotgun). The proposed method consists in the headspace extraction of VOCs in smokeless powders present in the propellant of ammunition. The sensitivity of this method was demonstrated with method detection limits (MDLs) 4-26 ng for diphenylamine (DPA), nitroglycerine (NG), 2,4-dinitrotoluene (2,4-DNT), and ethyl centralite (EC). In addition, a fast method was developed for the detection of the inorganic components (i.e., Ba, Pb, and Sb) characteristic of GSR presence by Laser Induced Breakdown Spectroscopy (LIBS). Advantages of LIBS include fast analysis (~ 12 seconds per sample) and good sensitivity, with expected MDLs in the range of 0.1-20 ng for target elements. Statistical analysis of the results using both techniques was performed to determine any correlation between the variables analyzed. This work demonstrates that the information collected from the analysis of organic components has the potential to improve the detection of GSR.