3 resultados para Esd

em Digital Commons at Florida International University


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to explore the attitudes, beliefs, and practices of community college professors regarding education for sustainable development (ESD). In-depth interviews with 14 professors from different disciplines were conducted. The participants taught at Miami Dade College, Florida, a Talloires Declaration signatory since 2006, and all had attended Green Studies professional development workshops. Written documents such as assignments and samples of student work were used for triangulation. The annual report of the college’s Earth Ethics Institute and its Web site served as additional sources. The interviews were recorded, transcribed, and analyzed for common themes. The Talloires Declaration’s 10-point action plan and the key characteristics of ESD (UN DESD, 2006) served as the conceptual framework. The study found that the professors considered ESD an essential issue. The majority discussed the economic and social aspects of ESD; however, the environmental aspect was mentioned most frequently. The professors’ conceptualizations of ESD were influenced by their experiences and evidenced by the metaphors they used. Although their engagement with ESD differed, the professors expressed optimism toward ESD related teaching and learning. They regarded ESD as compatible with their subjects, and most had already been infusing sustainability into their courses or planned to do so. Additionally, the participants’ teaching practices reflected many of the characteristics of ESD. Even though the professors considered ESD challenging, they believed that they could make contributions to the college’s effort. The metaphor of “Planting a Seed” was frequently used to describe this holistic approach. The study also found that many professors regarded interpersonal relationships and communication significant factors for the advancement of ESD. The participants described several challenges to integrating ESD at their college. These related to time constraints, density of curriculum, institutional size and fragmentation, dearth of administrative support and incentives, students’ lack of academic preparation and sustainability awareness, students’ inability to focus on ESD because of personal, social, or economic circumstances, and professors’ frustration about a divisive atmosphere as a result of their engagement with sustainability. Despite these obstacles, the professors believed that ESD could be successfully woven into the community college experience.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Advancements in the micro-and nano-scale fabrication techniques have opened up new avenues for the development of portable, scalable and easier-to-use biosensors. Over the last few years, electrodes made of carbon have been widely used as sensing units in biosensors due to their attractive physiochemical properties. The aim of this research is to investigate different strategies to develop functionalized high surface carbon micro/nano-structures for electrochemical and biosensing devices. High aspect ratio three-dimensional carbon microarrays were fabricated via carbon microelectromechanical systems (C-MEMS) technique, which is based on pyrolyzing pre-patterned organic photoresist polymers. To further increase the surface area of the carbon microstructures, surface porosity was introduced by two strategies, i.e. (i) using F127 as porogen and (ii) oxygen reactive ion etch (RIE) treatment. Electrochemical characterization showed that porous carbon thin film electrodes prepared by using F127 as porogen had an effective surface area (Aeff 185%) compared to the conventional carbon electrode. To achieve enhanced electrochemical sensitivity for C-MEMS based functional devices, graphene was conformally coated onto high aspect ratio three-dimensional (3D) carbon micropillar arrays using electrostatic spray deposition (ESD) technique. The amperometric response of graphene/carbon micropillar electrode arrays exhibited higher electrochemical activity, improved charge transfer and a linear response towards H2O2 detection between 250&mgr;M to 5.5mM. Furthermore, carbon structures with dimensions from 50 nano-to micrometer level have been fabricated by pyrolyzing photo-nanoimprint lithography patterned organic resist polymer. Microstructure, elemental composition and resistivity characterization of the carbon nanostructures produced by this process were very similar to conventional photoresist derived carbon. Surface functionalization of the carbon nanostructures was performed using direct amination technique. Considering the need for requisite functional groups to covalently attach bioreceptors on the carbon surface for biomolecule detection, different oxidation techniques were compared to study the types of carbon-oxygen groups formed on the surface and their percentages with respect to different oxidation pretreatment times. Finally, a label-free detection strategy using signaling aptamer/protein binding complex for platelet-derived growth factor oncoprotein detection on functionalized three-dimensional carbon microarrays platform was demonstrated. The sensor showed near linear relationship between the relative fluorescence difference and protein concentration even in the sub-nanomolar range with an excellent detection limit of 5 pmol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Advancements in the micro-and nano-scale fabrication techniques have opened up new avenues for the development of portable, scalable and easier-to-use biosensors. Over the last few years, electrodes made of carbon have been widely used as sensing units in biosensors due to their attractive physiochemical properties. The aim of this research is to investigate different strategies to develop functionalized high surface carbon micro/nano-structures for electrochemical and biosensing devices. High aspect ratio three-dimensional carbon microarrays were fabricated via carbon microelectromechanical systems (C-MEMS) technique, which is based on pyrolyzing pre-patterned organic photoresist polymers. To further increase the surface area of the carbon microstructures, surface porosity was introduced by two strategies, i.e. (i) using F127 as porogen and (ii) oxygen reactive ion etch (RIE) treatment. Electrochemical characterization showed that porous carbon thin film electrodes prepared by using F127 as porogen had an effective surface area (Aeff 185%) compared to the conventional carbon electrode. To achieve enhanced electrochemical sensitivity for C-MEMS based functional devices, graphene was conformally coated onto high aspect ratio three-dimensional (3D) carbon micropillar arrays using electrostatic spray deposition (ESD) technique. The amperometric response of graphene/carbon micropillar electrode arrays exhibited higher electrochemical activity, improved charge transfer and a linear response towards H2O2 detection between 250μM to 5.5mM. Furthermore, carbon structures with dimensions from 50 nano-to micrometer level have been fabricated by pyrolyzing photo-nanoimprint lithography patterned organic resist polymer. Microstructure, elemental composition and resistivity characterization of the carbon nanostructures produced by this process were very similar to conventional photoresist derived carbon. Surface functionalization of the carbon nanostructures was performed using direct amination technique. Considering the need for requisite functional groups to covalently attach bioreceptors on the carbon surface for biomolecule detection, different oxidation techniques were compared to study the types of carbon–oxygen groups formed on the surface and their percentages with respect to different oxidation pretreatment times. Finally, a label-free detection strategy using signaling aptamer/protein binding complex for platelet-derived growth factor oncoprotein detection on functionalized three-dimensional carbon microarrays platform was demonstrated. The sensor showed near linear relationship between the relative fluorescence difference and protein concentration even in the sub-nanomolar range with an excellent detection limit of 5 pmol.