5 resultados para Cannabis.

em Digital Commons at Florida International University


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cannabis sativa is the most frequently used of all illicit drugs in the United States. Cannabis has been used throughout history for its stems in the production of hemp fiber, for its seed for oil and food, and for its buds and leaves as a psychoactive drug. Short tandem repeats (STRs), were chosen as molecular markers because of their distinct advantages over other genetic methods. STRs are co-dominant, can be standardized such that reproducibility between laboratories can be easily achieved, have a high discrimination power and can be multiplexed. ^ In this study, six STR markers previously described for Cannabis were multiplexed into one reaction. The multiplex reaction was able to individualize 98 Cannabis samples (14 hemp and 84 marijuana, authenticated as originating from 33 of the 50 United States) and detect 29 alleles averaging 4.8 alleles per loci. The data did not relate the samples from the same state to each other. This is the first study to report a single reaction six-plex and apply it to the analysis of almost 100 Cannabis samples of known geographic collection site. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microsatellite markers were developed for Cannabis sativa L. (marijuana) to estimate the level of polymorphism, usefulness for DNA typing (genotype identification), and to measure the genetic relationships between the different plants. Twelve different oligonucleotide probes were used to screen an enriched microsatellite library of Cannabis sativa in which 49% of the clones contained microsatellite sequences. Characterization of microsatellite loci in Cannabis revealed that GA/CT was the most abundant class of isolated microsatellites representing 50% overall. Eleven polymorphic SSR markers were developed, derived from dinucleotide motifs and eight from trinucleotide motifs. A total of 52 alleles were detected averaging 4.7 alleles/locus. The expected heterozygosity of the eleven loci ranged between 0.368 and 0.710 and the common probability of identical genotypes was 1.8 x 107. The loci identified 27 unique profiles of the 41 Cannabis samples. The eleven microsatellite markers developed in this study were found to be useful for DNA fingerprinting and for assessing genetic relationships in Cannabis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study examined the relationships among dietary intake, substance use, socioeconomic and acculturation-related factors among Latinas in Miami-Dade County. Substance abuse is rising among Latinas. A fuller understanding of this problem is needed given the rise of the Hispanic population and the role of women in Latin society. A better understanding between substance use and dietary intake can guide nutrition interventions to reduce negative substance-related health consequences. A purposeful sample of 320 Latina mother/daughter dyads were recruited and interviewed face-to-face as part of the Latino Women's Study. Dietary intake was collected via a 24-hour recall and examined by (1) nutrient intake, (2) dietary patterns using cluster analysis, (3) quality of diet using the Healthy Eating Index (HEI) and (4) the Dietary Reference Intakes to determine nutrient adequacy. Substance use was measured with the Drug Use Frequency and the Healthy and Daily Living Form. Acculturation was measured with the Cultural Identity Scale. Three dietary patterns emerged based on the number of servings from the food groups established in MyPyramid. None were associated with substance use. Latinas who reported using cannabis, cocaine, sedatives without prescription and/or more than five alcoholic drinks on an occasion at least once a month during the previous twelve months had significantly lower HEI scores (64 vs. 60; F = 7.8, p = .005) and consumed fewer fruits (F = 16, p < .001) than non-users. Latinas classified as mothers whom reported consuming cannabis at least 1-7 times a week had significantly lower HEI scores (F = 4.23, p = .015, η2 = .027) than daughters with the same frequency of substance use. One dimension of acculturation, greater familiarity with Latin culture, was associated with good dietary quality (β = .142, p = .012) regardless of any type of substance used or income level. There was a high prevalence of inadequacy of folic acid intake (50-75%) regardless of substance use. Substance users consumed significantly more energy (1,798 vs. 1,615; p = .027) than non-users. Although effect sizes were small, associations between dietary intake and substance use among Latinas deserve further exploration while acknowledging the combined association with acculturation. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The need for elemental analysis of biological matrices such as bone, teeth, and plant matter for sourcing purposes has emerged within the forensic and geochemical laboratories. Trace elemental analyses for the comparison of materials such as glass by inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS has been shown to offer a high degree of discrimination between different manufacturing sources. Unit resolution ICP-MS instruments may suffer from some polyatomic interferences including 40Ar16O+, 40Ar 16O1H+, and 40Ca 16O+ that affect iron measurement at trace levels. Iron is an important element in the analysis of glass and also of interest for the analysis of several biological matrices. A comparison of the analytical performance of two different ICP-MS systems for iron analysis in glass for determining the method detection limits (MDLs), accuracy, and precision of the measurement is presented. Acid digestion and laser ablation methods are also compared. Iron polyatomic interferences were reduced or resolved by using dynamic reaction cell and high resolution ICP-MS. MDLs as low as 0.03 μg g-1 and 0.14 μg g-1 for laser ablation and solution based analyses respectively were achieved. The use of helium as a carrier gas demonstrated improvement in the detection limits of both iron isotopes (56Fe and 57Fe) in medium resolution for the HR-ICP-MS and with a dynamic reaction cell (DRC) coupled to a quadrupole ICP-MS system. ^ The development and application of robust analytical methods for the quantification of trace elements in biological matrices has lead to a better understanding of the potential utility of these measurements in forensic chemical analyses. Standard reference materials (SRMs) were used in the development of an analytical method using HR-ICP-MS and LA-HR-ICP-MS that was subsequently applied on the analysis of real samples. Bone, teeth and ashed marijuana samples were analyzed with the developed method. ^ Elemental analysis of bone samples from 12 different individuals provided discrimination between individuals, when femur and humerus bones were considered separately. Discrimination of 14 teeth samples based on elemental composition was achieved with the exception of one case where samples from the same individual were not associated with each other. The discrimination of 49 different ashed plant (cannabis) samples was achieved using the developed method. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The need for elemental analysis of biological matrices such as bone, teeth, and plant matter for sourcing purposes has emerged within the forensic and geochemical laboratories. Trace elemental analyses for the comparison of aterials such as glass by inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS has been shown to offer a high degree of discrimination between different manufacturing sources. Unit resolution ICP-MS instruments may suffer from some polyatomic interferences including 40Ar16O+, 40Ar16O1H+, and 40Ca16O+ that affect iron measurement at trace levels. Iron is an important element in the analysis of glass and also of interest for the analysis of several biological matrices. A comparison of the nalytical performance of two different ICP-MS systems for iron analysis in glass for determining the method detection limits (MDLs), accuracy, and precision of the measurement is presented. Acid digestion and laser ablation methods are also compared. Iron polyatomic interferences were reduced or resolved by using dynamic reaction cell and high resolution ICP-MS. MDLs as low as 0.03 ìg g-1 and 0.14 ìg g-1 for laser ablation and solution based analyses respectively were achieved. The use of helium as a carrier gas demonstrated improvement in the detection limits of both iron isotopes (56Fe and 57Fe) in medium resolution for the HR-ICP-MS and with a dynamic reaction cell (DRC) coupled to a quadrupole ICP-MS system. The development and application of robust analytical methods for the quantification of trace elements in biological matrices has lead to a better understanding of the potential utility of these measurements in forensic chemical analyses. Standard reference materials (SRMs) were used in the development of an analytical method using HR-ICP-MS and LA-HR-ICP-MS that was subsequently applied on the analysis of real samples. Bone, teeth and ashed marijuana samples were analyzed with the developed method. Elemental analysis of bone samples from 12 different individuals provided discrimination between individuals, when femur and humerus bones were considered separately. Discrimination of 14 teeth samples based on elemental composition was achieved with the exception of one case where samples from the same individual were not associated with each other. The discrimination of 49 different ashed plant (cannabis)samples was achieved using the developed method.