3 resultados para testes de equipamentos
em Universidade Federal de Uberlândia
Resumo:
People bedridden by paralysis/motor disability are subject to several problems due to lack of movement. Then, it is necessary to use equipments that enable the people bedridden stand up and walk, so as to reduce the problems due to lack of movement and the time of rehabilitation, impacting directly on its quality of life. The aim of this work is the development of an exoskeleton to make the movement of people with paralysis / motor impairment in the lower limbs, without help of third parties, to be activated by the user. To provide support, stability and security to the deficient, it was decided to use a structure formed by four legs, being each leg consisting of a parallel chain. The gait was obtained by combining the movement of two mechanisms: crank/rocker, responsible for oscillatory motion of the leg, and cam/follower, responsible for the foot motion on the desired trajectory. To achieve the aim of this work was conducted a study about the types of exoskeletons for locomotion/rehabilitation of people with lower limb paralysis and presented a study on the movement of the lower limb joints. It also presented a mathematical model to obtain the desired path to the foot of the exoskeleton, the static model and the design of the structure elements. In the sequence is presented the simulation of movements of a people during the human gait, experimental tests and the comparison with the human gait developed by a people without disabilities.
Resumo:
This study aims to evaluate the uncertainty associated with measurements made by aneroid sphygmomanometer, neonatal electronic balance and electrocautery. Therefore, were performing repeatability tests on all devices for the subsequent execution of normality tests using Shapiro-Wilk; identification of influencing factors that affect the measurement result of each measurement; proposition of mathematical models to calculate the measurement uncertainty associated with measuring evaluated for all equipament and calibration for neonatal electronic balance; evaluation of the measurement uncertainty; and development of a computer program in Java language to systematize the calibration uncertainty of estimates and measurement uncertainty. It was proposed and carried out 23 factorial design for aneroid sphygmomanometer order to investigate the effect of temperature factors, patient and operator and another 32 planning for electrocautery, where it investigated the effects of temperature factors and output electrical power. The expanded uncertainty associated with the measurement of blood pressure significantly reduced the extent of the patient classification tracks. In turn, the expanded uncertainty associated with the mass measurement with neonatal balance indicated a variation of about 1% in the dosage of medication to neonates. Analysis of variance (ANOVA) and the Turkey test indicated significant and indirectly proportional effects of temperature factor in cutting power values and clotting indicated by electrocautery and no significant effect of factors investigated for aneroid sphygmomanometer.
Resumo:
The hydrocycloning operation has a goal to separate solid-liquid suspensions and liquid-liquid emulsions through the centrifugal force action. Hydrocyclones are equipment with reduced size and used in both clarification and thickening. This device is used in many areas, like petrochemical and minerals process, and accumulate advantages like versatility and low cost of maintenance. However, the demand to improve the process and to reduce the costs has motivated several studies of equipment optimization. The filtering hydrocyclone is a non-conventional equipment developed at FEQUI/UFU with objective to improve the hydrocycloning separation efficiency. The purpose of this study is to evaluate the operating conditions of feed concentration and underflow diameter on the performance of a filtering geometry optimized to minimization of energy costs. The filtration effect was investigated through the comparison between the performance of the Optimized Filtering Hydrocyclone (HCOF) and the Optimized Concentrator Hydrocyclone (HCO). Because of the resemblance of hydrocyclones performance, the filtration did not represent significant effect on the performance of the HCOF. It was found that in this geometry the decrease of the variable underflow diameter was very favorable to thickening operation. The suspension concentration of quartzite at 1.0% of solids in volume was increased about 42 times when the 3 mm underflow diameter was used. The increase on the feed solid percentage was good for decreasing the energy spent, so that a minimum number of Euler of 730 was achieved at CVA = 10.0%v. However, a greater amount of solids in suspension leads to a lower efficiency of the equipment. Therefore, to minimize the underflow-to-throughput ratio and keep a high efficiency level, it is indicated to work with dilute suspension (CVA = 1.0%) and 3 mm underflow diameter (η = 67%). But if it is necessary to work with high feed concentration, the use of 5 mm underflow diameter provides a rise in the efficiency. The HCO hydrocyclone was compared to the traditional family of hydrocyclones Rietema and presented advantages like higher efficiency (34% higher in average) and lower energy costs (20% lower in average). Finally, the efficiency curves and project equation have been raised for the HCO hydrocyclone each with satisfactory adjust.