2 resultados para Torques magnéticos
em Universidade Federal de Uberlândia
Resumo:
In this work it was developed mathematical resolutions taking as parameter maximum intensity values for the interference analysis of electric and magnetic fields and was given two virtual computer system that supports families of CDMA and WCDMA technologies. The first family were developed computational resources to solve electric and magnetic field calculations and power densities in Radio Base stations , with the use of CDMA technology in the 800 MHz band , taking into account the permissible values referenced by the Commission International Protection on non-Ionizing Radiation . The first family is divided into two segments of calculation carried out in virtual operation. In the first segment to compute the interference field radiated by the base station with input information such as radio channel power; Gain antenna; Radio channel number; Operating frequency; Losses in the cable; Attenuation of direction; Minimum Distance; Reflections. Said computing system allows to quickly and without the need of implementing instruments for measurements, meet the following calculated values: Effective Radiated Power; Sector Power Density; Electric field in the sector; Magnetic field in the sector; Magnetic flux density; point of maximum permissible exposure of electric field and power density. The results are shown in charts for clarity of view of power density in the industry, as well as the coverage area definition. The computer module also includes folders specifications antennas, cables and towers used in cellular telephony, the following manufacturers: RFS World, Andrew, Karthein and BRASILSAT. Many are presented "links" network access "Internet" to supplement the cable specifications, antennas, etc. . In the second segment of the first family work with more variables , seeking to perform calculations quickly and safely assisting in obtaining results of radio signal loss produced by ERB . This module displays screens representing propagation systems denominated "A" and "B". By propagating "A" are obtained radio signal attenuation calculations in areas of urban models , dense urban , suburban , and rural open . In reflection calculations are present the reflection coefficients , the standing wave ratio , return loss , the reflected power ratio , as well as the loss of the signal by mismatch impedance. With the spread " B" seek radio signal losses in the survey line and not targeted , the effective area , the power density , the received power , the coverage radius , the conversion levels and the gain conversion systems radiant . The second family of virtual computing system consists of 7 modules of which 5 are geared towards the design of WCDMA and 2 technology for calculation of telephone traffic serving CDMA and WCDMA . It includes a portfolio of radiant systems used on the site. In the virtual operation of the module 1 is compute-: distance frequency reuse, channel capacity with noise and without noise, Doppler frequency, modulation rate and channel efficiency; Module 2 includes computes the cell area, thermal noise, noise power (dB), noise figure, signal to noise ratio, bit of power (dBm); with the module 3 reaches the calculation: breakpoint, processing gain (dB) loss in the space of BTS, noise power (w), chip period and frequency reuse factor. Module 4 scales effective radiated power, sectorization gain, voice activity and load effect. The module 5 performs the calculation processing gain (Hz / bps) bit time, bit energy (Ws). Module 6 deals with the telephone traffic and scales 1: traffic volume, occupancy intensity, average time of occupancy, traffic intensity, calls completed, congestion. Module 7 deals with two telephone traffic and allows calculating call completion and not completed in HMM. Tests were performed on the mobile network performance field for the calculation of data relating to: CINP , CPI , RSRP , RSRQ , EARFCN , Drop Call , Block Call , Pilot , Data Bler , RSCP , Short Call, Long Call and Data Call ; ECIO - Short Call and Long Call , Data Call Troughput . As survey were conducted surveys of electric and magnetic field in an ERB , trying to observe the degree of exposure to non-ionizing radiation they are exposed to the general public and occupational element. The results were compared to permissible values for health endorsed by the ICNIRP and the CENELEC .
Resumo:
CHAPTER 1 - This study histologically evaluated two implant designs: a classic thread design versus another specifically designed for healing chamber formation placed with two drilling protocols. Forty dental implants (4.1 mm diameter) with two different macrogeometries were inserted in the tibia of 10 Beagle dogs, and maximum insertion torque was recorded. Drilling techniques were: until 3.75 mm (regular-group); and until 4.0 mm diameter (overdrillinggroup) for both implant designs. At 2 and 4 weeks, samples were retrieved and processed for histomorphometric analysis. For torque and BIC (bone-to-implant contact) and BAFO (bone area fraction occupied), a general-linear model was employed including instrumentation technique and time in vivo as independent. The insertion torque recorded for each implant design and drilling group significantly decreased as a function of increasing drilling diameter for both implant designs (p<0.001). No significant differences were detected between implant designs for each drilling technique (p>0.18). A significant increase in BIC was observed from 2 to 4 weeks for both implants placed with the overdrilling technique (p<0.03) only, but not for those placed in the 3.75 mm drilling sites (p>0.32). Despite the differences between implant designs and drilling technique an intramembranous-like healing mode with newly formed woven bone prevailed. CHAPTER 2 - The objective of this preliminary histologic study was to determine whether the alteration of drilling protocols (oversized, intermediate, undersized drilling) present different biologic responses at early healing periods of 2 weeks in vivo in a beagle dog model. Ten beagle dogs were acquired and subjected to surgeries in the tibia 2 weeks before euthanasia. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.5 mm, 3.75 mm, and 4.0 mm in final diameter. The insertion and removal torque was recorded for all samples. Statistical significance was set to 95% level of confidence and the number of dogs was considered as the statistical unit for all comparisons. For the torque and BIC and BAFO, a general linear model was employed including instrumentation technique and time in vivo as independent. Overall, the insertion torque increased as a function of drilling diameter from 4.0 mm, to 3.75 mm, to 3.5 mm, with a significant difference in torque levels between all groups (p<0.001). Statistical assessment of BIC and BAFO showed significantly higher values for the 3.75 mm (recommended) drilling group was observed relative to the other two groups (p<0.001). Different drilling dimensions resulted in variations in insertion torque values (primary stability) and different pattern of healing and interfacial remodeling was observed for the different groups. CHAPTER 3 - The present study evaluated the effect of different drilling dimensions (undersized, regular, and oversized) in the insertion and removal torques of dental implants in a beagle dog model. Six beagle dogs were acquired and subjected to bilateral surgeries in the radii 1 and 3 weeks before euthanasia. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.2 mm, 3.5 mm, and 3.8 mm in final diameter. The insertion and removal torque was recorded for all samples. Statistical analysis was performed by paired t tests for repeated measures and by t tests assuming unequal variances (all at the 95% level of significance). Overall, the insertion torque and removal torque levels obtained were inversely proportional to the drilling dimension, with a significant difference detected between the 3.2 mm and 3.5 mm relative to the 3.8 mm groups (P < 0.03). Although insertion torque–removal torque paired observations was statis- tically maintained for the 3.5 mm and 3.8 mm groups, a significant decrease in removal torque values relative to insertion torque levels was observed for the 3.2 mm group. A different pattern of healing and interfacial remodeling was observed for the different groups. Different drilling dimensions resulted in variations in insertion torque values (primary stability) and stability maintenance over the first weeks of bone healing.