2 resultados para Termo-mecânica. Interconector cerâmico. Interconector metálico. Cromita de lantânio. PaCOS
em Universidade Federal de Uberlândia
Resumo:
This work presents an experimental investigation of thermal hydraulic performance of the nanofluid composed by graphene nanoparticles dispersed in a mixture of water and ethylene glycol at a ratio of 70:30% by volume. The tests were carried out under forced convection inside a circular tube with uniform heat flux on the wall for the laminar-turbulent transition regime. The mass flow rate ranged from 40 to 70 g/s corresponding to Reynolds numbers between 3000 and 7500. The heat flux was maintained constant at values of 11, 16 and 21 kW/m², as well as the inlet temperature of 15, 20 and 25°C. Three samples were produced with the nanofluid volumetric concentration of 0.05%, 0.10% and 0.15%. Thermophysical properties were experimentaly measured for all samples that were critically compared and discussed with theoretical models most commonly used in the literature. Initially, experiments with distilled water confirmed the validity of the experimental equipment for the thermo-hydraulic tests. Therefore, nanofluid samples that showed the highest thermal conductivity, corresponding to the volumetric concentrations of 0.15% and 0.10%, were subjected to the tests. The thermal-hydraulic performance for both samples was unsatisfactory. The heat transfer coefficients for convection of nanofluids reduced 21% in average, for the sample with = 0.15% and 26% and for =0.10%. The pressure drop of the samples was higher than the base fluid. Finally, the pressure drop and heat transfer coefficient by convection of both samples were also compared to theoretical models. The models used for pressure drop showed an excellent agreement with experimental results, which is remarkable considering the transitional flow.
Resumo:
Background: Ventilator-associated pneumonia (VAP) is a health care related infection and the second leading cause of nosocomial infections linked to morbidity and mortality rates. Therefore, the implementation of care guideline protocols has become necessary for critically ill patients in ICUs in order to provide adequate treatment. Objective: To assess the impact of a package called FAST HUG in PAV ; analyze the risk factors for occurrence of VAP in adult patients at an ICU of a private hospital ; analyze the clinical characteristics of patients who were or were not submitted to the FAST HUG ; analyze the etiology of microorganisms related to EPI ; determine the cost of hospitalization in patients with pneumonia and in patients who received the FAST HUG.Methods: The study was performed in a private hospital that has an 8-bed ICU. It was divided into two phases: before implementing FAST HUG, from August 2011 to August 2012 and after the implementation of FAST HUG, from September 2012 to December 2013. An individual form for each patient in the study was filled out by using information taken electronically from the hospital medical records. The following data for each patient was obtained: age, gender, reason for hospitalization, the use of three or more types of antibiotics, length of stay, intubation time and progress. Findings: After the implementation of FAST HUG, there was an observable decrease in the occurrence of VAP (p <0.01), as well as a reduction in mortality rates (p <0.01). It also shows that the intervention performed in the study resulted in a significant reduction in ICU hospital costs (p <0.05).Conclusion: The implementation of FAST HUG reduced the cases of VAP. Thus, decreasing costs, reducing mortality rates and length of stay, which therefore resulted in an improvement to the overall quality of care.