2 resultados para PROTOCOLO DE KIOTO

em Universidade Federal de Uberlândia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Advances in neonatology resulted in reducing the mortality rate and the consequent increase in survival of newborn pre terms (PTN). On the other hand, there was also a considerable increase in the risk of developing health care-related infection (HAI) in its most invasive, especially for bloodstream. This situation is worrying, and prevent the occurrence of it is a challenge and becomes one of the priorities in the Neonatal Intensive Care Unit (NICU). Sepsis is the main cause of death in critical neonates and affects more than one million newborns each year, representing 40% of all deaths in neonates. The incidence of late sepsis can reach 50% in NICUs. Currently the major responsible for the occurrence of sepsis in developed countries is the coagulase negative Staphylococcus (CoNS), followed by S. aureus. The cases of HAIs caused by resistant isolates for major classes of antimicrobial agents have been increasingly frequent in the NICU. Therefore, vancomycin has to be prescribed more frequently, and, today, the first option in the treatment of bloodstream infections by resistant Staphylococcus. The objectives of this study were to assess the impact on late sepsis in epidemiology III NICU after the change of the use of antimicrobials protocol; check the frequency of multiresistant microorganisms; assess the number of neonates who came to death. This study was conducted in NICU Level III HC-UFU. three study groups were formed based on the use of the proposed late sepsis treatment protocol, with 216 belonging to the period A, 207 B and 209 to the C. The work was divided into three stages: Period A: data collected from neonates admitted to the unit between September 2010 to August 2011. was using treatment of late sepsis: with oxacillin and gentamicin, oxacillin and amikacin, oxacillin and cefotaxime. Period B: data were collected from March 2012 to February 2013. Data collection was started six months after protocol change. Due to the higher prevalence of CoNS, the initial protocol was changed to vancomycin and cefotaxime. Period C: data were collected from newborns inteerne in the unit from September 2013 to August 2014. Data collection was started six months after the protocol change, which occurred in March 2013. From the 632 neonates included in this study, 511 (80,8%) came from the gynecology and obstetrics department of the HC-UFU. The mean gestational age was 33 weeks and the prevailing sex was male (55,7%). Seventy-nine percent of the studied neonates were hospitalized at the NICU HC-UFU III because of complications related to the respiratory system. Suspicion of sepsis took to hospitalization in the unit of 1,9% of newborns. In general, the infection rate was 34,5%, and the most frequent infectious sepsis syndrome 81,2%. There was a tendency to reduce the number of neonates who died between periods A 11 and C (p = 0,053). From the 176 cases of late sepsis, 73 were clinical sepsis and 103 had laboratory confirmation, with greater representation of Gram positive bacteria, which corresponded to 67.2% of the isolates and CoNS the most frequent micro-organism (91,5%). There was a statistically significant difference in the reduction of isolation of Gram positive microorganisms between periods A and C (p = 0,0365) as well as in reducing multidrug-resistant CoNS (A and B period p = 0,0462 and A and C period, p = 0,158). This study concluded that: the CoNS was the main microorganism responsible for the occurrence of late sepsis in neonates in the NICU of HC-UFU; the main risk factors for the occurrence of late sepsis were: birth weight <1500 g, use of PICC and CUV, need for mechanical ventilation and parenteral nutrition, SNAPPE> 24 and length of stay more than seven days; the new empirical treatment protocol late sepsis, based on the use of vancomycin associated cefepime, it was effective, since promoted a reduction in insulation CoNS blood cultures between the pre and post implementation of the Protocol (A and C, respectively); just as there was a reduction in the number of newborns who evolved to death between periods A and C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CHAPTER 1 - This study histologically evaluated two implant designs: a classic thread design versus another specifically designed for healing chamber formation placed with two drilling protocols. Forty dental implants (4.1 mm diameter) with two different macrogeometries were inserted in the tibia of 10 Beagle dogs, and maximum insertion torque was recorded. Drilling techniques were: until 3.75 mm (regular-group); and until 4.0 mm diameter (overdrillinggroup) for both implant designs. At 2 and 4 weeks, samples were retrieved and processed for histomorphometric analysis. For torque and BIC (bone-to-implant contact) and BAFO (bone area fraction occupied), a general-linear model was employed including instrumentation technique and time in vivo as independent. The insertion torque recorded for each implant design and drilling group significantly decreased as a function of increasing drilling diameter for both implant designs (p<0.001). No significant differences were detected between implant designs for each drilling technique (p>0.18). A significant increase in BIC was observed from 2 to 4 weeks for both implants placed with the overdrilling technique (p<0.03) only, but not for those placed in the 3.75 mm drilling sites (p>0.32). Despite the differences between implant designs and drilling technique an intramembranous-like healing mode with newly formed woven bone prevailed. CHAPTER 2 - The objective of this preliminary histologic study was to determine whether the alteration of drilling protocols (oversized, intermediate, undersized drilling) present different biologic responses at early healing periods of 2 weeks in vivo in a beagle dog model. Ten beagle dogs were acquired and subjected to surgeries in the tibia 2 weeks before euthanasia. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.5 mm, 3.75 mm, and 4.0 mm in final diameter. The insertion and removal torque was recorded for all samples. Statistical significance was set to 95% level of confidence and the number of dogs was considered as the statistical unit for all comparisons. For the torque and BIC and BAFO, a general linear model was employed including instrumentation technique and time in vivo as independent. Overall, the insertion torque increased as a function of drilling diameter from 4.0 mm, to 3.75 mm, to 3.5 mm, with a significant difference in torque levels between all groups (p<0.001). Statistical assessment of BIC and BAFO showed significantly higher values for the 3.75 mm (recommended) drilling group was observed relative to the other two groups (p<0.001). Different drilling dimensions resulted in variations in insertion torque values (primary stability) and different pattern of healing and interfacial remodeling was observed for the different groups. CHAPTER 3 - The present study evaluated the effect of different drilling dimensions (undersized, regular, and oversized) in the insertion and removal torques of dental implants in a beagle dog model. Six beagle dogs were acquired and subjected to bilateral surgeries in the radii 1 and 3 weeks before euthanasia. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.2 mm, 3.5 mm, and 3.8 mm in final diameter. The insertion and removal torque was recorded for all samples. Statistical analysis was performed by paired t tests for repeated measures and by t tests assuming unequal variances (all at the 95% level of significance). Overall, the insertion torque and removal torque levels obtained were inversely proportional to the drilling dimension, with a significant difference detected between the 3.2 mm and 3.5 mm relative to the 3.8 mm groups (P < 0.03). Although insertion torque–removal torque paired observations was statis- tically maintained for the 3.5 mm and 3.8 mm groups, a significant decrease in removal torque values relative to insertion torque levels was observed for the 3.2 mm group. A different pattern of healing and interfacial remodeling was observed for the different groups. Different drilling dimensions resulted in variations in insertion torque values (primary stability) and stability maintenance over the first weeks of bone healing.