2 resultados para Occupancy

em Universidade Federal de Uberlândia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The implementation of the railway in Triângulo Mineiro and Alto Paranaíba helped to develop the area and connexion with other states: São Paulo, Goiás and Mato Grosso. The railway used to transport people and goods throughout many train stations in urban and rural areas and some major railroad complexes. There were many factors that led to the decline and abandonment of these properties: governmental policies which were in favour of road transportation and automotive industry, the replacement of the steam locomotive for electric and electric-diesel locomotives, changing part of the railway plan, removal of railways and loss of function of the buildings, extinction of passenger trains, which led the stations to lose its main purpose: people transport. 53% of the stations built inside the study area were demolished and most of them are in rural areas. There are several situations: stations on a precarious conservation state, most of them in the city s rural area, stations being used in urban and rural areas with new uses, stations working with cargo and goods transportation. The stations in Triângulo Mineiro and Alto Paranaíba area in Minas Gerais are the object of this dissertation, wherein the main interest lies on the stations that are in operation, 21 buildings, seeking to verify their conservation state, their agents and role in preserving the train memory. Maps, charts and tables were made for this collection s understanding, having visited the stations that are listed by the cultural heritage and the ones that are in operation with new functions. Field records were made allowing the understanding of these properties in operation. It is observed that only the buildings listing, despite ensuring the non-demolition, does not help on the use and preservation of these stations, because there are some buildings that have this protection level, but are abandoned and in disrepair. The use of these stations by a train company, operating with cargo and goods transportation do not also guarantee the buildings preservation, as they are not treated with any preservation interest, their maintenance are precarious. The using by these companies are various, however, only a few stations have internal spaces dedicated to the railroad memory. Most of the stations did not have preservation projects with architects and specialists participation and the major concern, during maintenance process, is on the building s external part. The stations conservation begins on the local government interest, that preserve these properties, most of them are in urban areas, the major challenge is on their using definition and occupancy, especially in the countryside, wherein the buildings uses must be sustainable, as regards the appreciation and management of this heritage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work it was developed mathematical resolutions taking as parameter maximum intensity values for the interference analysis of electric and magnetic fields and was given two virtual computer system that supports families of CDMA and WCDMA technologies. The first family were developed computational resources to solve electric and magnetic field calculations and power densities in Radio Base stations , with the use of CDMA technology in the 800 MHz band , taking into account the permissible values referenced by the Commission International Protection on non-Ionizing Radiation . The first family is divided into two segments of calculation carried out in virtual operation. In the first segment to compute the interference field radiated by the base station with input information such as radio channel power; Gain antenna; Radio channel number; Operating frequency; Losses in the cable; Attenuation of direction; Minimum Distance; Reflections. Said computing system allows to quickly and without the need of implementing instruments for measurements, meet the following calculated values: Effective Radiated Power; Sector Power Density; Electric field in the sector; Magnetic field in the sector; Magnetic flux density; point of maximum permissible exposure of electric field and power density. The results are shown in charts for clarity of view of power density in the industry, as well as the coverage area definition. The computer module also includes folders specifications antennas, cables and towers used in cellular telephony, the following manufacturers: RFS World, Andrew, Karthein and BRASILSAT. Many are presented "links" network access "Internet" to supplement the cable specifications, antennas, etc. . In the second segment of the first family work with more variables , seeking to perform calculations quickly and safely assisting in obtaining results of radio signal loss produced by ERB . This module displays screens representing propagation systems denominated "A" and "B". By propagating "A" are obtained radio signal attenuation calculations in areas of urban models , dense urban , suburban , and rural open . In reflection calculations are present the reflection coefficients , the standing wave ratio , return loss , the reflected power ratio , as well as the loss of the signal by mismatch impedance. With the spread " B" seek radio signal losses in the survey line and not targeted , the effective area , the power density , the received power , the coverage radius , the conversion levels and the gain conversion systems radiant . The second family of virtual computing system consists of 7 modules of which 5 are geared towards the design of WCDMA and 2 technology for calculation of telephone traffic serving CDMA and WCDMA . It includes a portfolio of radiant systems used on the site. In the virtual operation of the module 1 is compute-: distance frequency reuse, channel capacity with noise and without noise, Doppler frequency, modulation rate and channel efficiency; Module 2 includes computes the cell area, thermal noise, noise power (dB), noise figure, signal to noise ratio, bit of power (dBm); with the module 3 reaches the calculation: breakpoint, processing gain (dB) loss in the space of BTS, noise power (w), chip period and frequency reuse factor. Module 4 scales effective radiated power, sectorization gain, voice activity and load effect. The module 5 performs the calculation processing gain (Hz / bps) bit time, bit energy (Ws). Module 6 deals with the telephone traffic and scales 1: traffic volume, occupancy intensity, average time of occupancy, traffic intensity, calls completed, congestion. Module 7 deals with two telephone traffic and allows calculating call completion and not completed in HMM. Tests were performed on the mobile network performance field for the calculation of data relating to: CINP , CPI , RSRP , RSRQ , EARFCN , Drop Call , Block Call , Pilot , Data Bler , RSCP , Short Call, Long Call and Data Call ; ECIO - Short Call and Long Call , Data Call Troughput . As survey were conducted surveys of electric and magnetic field in an ERB , trying to observe the degree of exposure to non-ionizing radiation they are exposed to the general public and occupational element. The results were compared to permissible values for health endorsed by the ICNIRP and the CENELEC .