3 resultados para Filtração por membranas
em Universidade Federal de Uberlândia
Resumo:
CHAPTER II - This study evaluated the effects of two different types of acute aerobic exercise on the osmotic stability of human erythrocyte membrane and on different hematological and biochemical variables that are associated with this membrane property. The study population consisted of 20 healthy and active men. Participants performed single sessions of two types of exercise. The first session consisted of 60 min of moderate-intensity continuous exercise (MICE). The second session, executed a week later, consisted of high-intensity interval exercise (HIIE) until exhaustion. The osmotic stability of the erythrocyte membrane was represented by the inverse of the salt concentration (1/H50) at the midpoint of the sigmoidal curve of dependence between the absorbance of hemoglobin and the NaCl concentration. The values of 1/H50 changed from 2.29 ± 0.1 to 2.33 ± 0.09 after MICE and from 2.30 ± 0.08 to 2.23 ± 0.12 after HIIE. In MICE has occurred an increase in the mean corpuscular volume, probably due to in vivo lysis of older erythrocytes, with preservation of cells that were larger and more resistant to in vitro lysis. The study showed that a single bout of acute exercise affected the erythrocyte osmotic stability, which increased after MICE and decreased after HIIE.
Resumo:
Metabolic syndrome (MS) is defined as a set of cardiovascular risk factors including obesity, systemic high blood pressure (SHBP), changes in glucose metabolism and dyslipidemia. The prevalence of MS in renal transplant recipients (RTR) ranges from 15% to 65%, increasing the risk of cardiovascular disease (CVD) and reducing renal allograft survival in the long term. The objectives of this study were to determine the prevalence and frequency of MS in renal transplant patients according to gender and time of transplantation and to evaluate renal function in patients with and without MS. Patients and Methods: Crosssectional study conducted from August 2012 to September 2013 involving 153 renal transplant recipients. MS was defined according to the National Cholesterol Education Program (NCEP) Adult Treatment Panel III (ATP III). The sample was divided into two groups: patients with metabolic syndrome (WMS patients) and patients without metabolic syndrome (WoMS patients) and according to gender. The WMS patients were stratified into quartiles according to the renal transplantation period (RTP), and variables related to MS were analyzed for both sexes. Results: MS was diagnosed in 58.1% of the studied population, specifically in MS was found 58.4% of men and 41.6% of women (P ˂ 0.05). The male and female with MS were 48.8 ± 11.6 years old vs. 47.1 ± 12.7 years old and the time of post transplantation was 76.1 ± 76.5 months vs. 84.7 ± 65.4 months, respectively (P >0,05). When we compared the sexes in the WMS group, systolic blood pressure (SBP) was higher in men (137.0 ± 18.1 vs. 128.9 ± 13.6 mmHg, P= 0.029), while the other components of MS did not exhibit significant differences. With respect to renal function, when we compared the sexes in the WMS group, the serum creatinine (sCr) was higher in men (1.73 ± 0.69 vs. 1.31 ± 0.47 mg/dL, P= 0.0012), while the urinary protein/creatinine ratio was higher in women (0.48 ± 0.69 vs. 0.37 ± 0.48 mg/dL, P=0.0150). We found no significant difference in the estimated glomerular filtration rate (eGFR) between WMS and WoMS patients for women and men (50.6 ± 19.1 vs. 50.1 ± 18.3 mL/min/1.73 m², P=0.909). We found a significant positive association between eGFR and HDL-c levels (r=0.3371; P=0.0145) for WMS men. The MS components showed no significant differences in RTP for different interquartile ranges, except for diastolic blood pressure (DBP) in women, where there was a significant variation among the quartiles evaluated (P=0.0009). Conclusion: the prevalence of MS was similar in the different quartiles in both sexes, in relation to time post TX. There was no significant difference in eGFR in patients WMS and WoMS, in both sexes. Concluding that the MS did not vary in relation to time post transplant.
Resumo:
The hydrocycloning operation has a goal to separate solid-liquid suspensions and liquid-liquid emulsions through the centrifugal force action. Hydrocyclones are equipment with reduced size and used in both clarification and thickening. This device is used in many areas, like petrochemical and minerals process, and accumulate advantages like versatility and low cost of maintenance. However, the demand to improve the process and to reduce the costs has motivated several studies of equipment optimization. The filtering hydrocyclone is a non-conventional equipment developed at FEQUI/UFU with objective to improve the hydrocycloning separation efficiency. The purpose of this study is to evaluate the operating conditions of feed concentration and underflow diameter on the performance of a filtering geometry optimized to minimization of energy costs. The filtration effect was investigated through the comparison between the performance of the Optimized Filtering Hydrocyclone (HCOF) and the Optimized Concentrator Hydrocyclone (HCO). Because of the resemblance of hydrocyclones performance, the filtration did not represent significant effect on the performance of the HCOF. It was found that in this geometry the decrease of the variable underflow diameter was very favorable to thickening operation. The suspension concentration of quartzite at 1.0% of solids in volume was increased about 42 times when the 3 mm underflow diameter was used. The increase on the feed solid percentage was good for decreasing the energy spent, so that a minimum number of Euler of 730 was achieved at CVA = 10.0%v. However, a greater amount of solids in suspension leads to a lower efficiency of the equipment. Therefore, to minimize the underflow-to-throughput ratio and keep a high efficiency level, it is indicated to work with dilute suspension (CVA = 1.0%) and 3 mm underflow diameter (η = 67%). But if it is necessary to work with high feed concentration, the use of 5 mm underflow diameter provides a rise in the efficiency. The HCO hydrocyclone was compared to the traditional family of hydrocyclones Rietema and presented advantages like higher efficiency (34% higher in average) and lower energy costs (20% lower in average). Finally, the efficiency curves and project equation have been raised for the HCO hydrocyclone each with satisfactory adjust.