3 resultados para Falha óssea
em Universidade Federal de Uberlândia
Resumo:
CHAPTER 1 - This study histologically evaluated two implant designs: a classic thread design versus another specifically designed for healing chamber formation placed with two drilling protocols. Forty dental implants (4.1 mm diameter) with two different macrogeometries were inserted in the tibia of 10 Beagle dogs, and maximum insertion torque was recorded. Drilling techniques were: until 3.75 mm (regular-group); and until 4.0 mm diameter (overdrillinggroup) for both implant designs. At 2 and 4 weeks, samples were retrieved and processed for histomorphometric analysis. For torque and BIC (bone-to-implant contact) and BAFO (bone area fraction occupied), a general-linear model was employed including instrumentation technique and time in vivo as independent. The insertion torque recorded for each implant design and drilling group significantly decreased as a function of increasing drilling diameter for both implant designs (p<0.001). No significant differences were detected between implant designs for each drilling technique (p>0.18). A significant increase in BIC was observed from 2 to 4 weeks for both implants placed with the overdrilling technique (p<0.03) only, but not for those placed in the 3.75 mm drilling sites (p>0.32). Despite the differences between implant designs and drilling technique an intramembranous-like healing mode with newly formed woven bone prevailed. CHAPTER 2 - The objective of this preliminary histologic study was to determine whether the alteration of drilling protocols (oversized, intermediate, undersized drilling) present different biologic responses at early healing periods of 2 weeks in vivo in a beagle dog model. Ten beagle dogs were acquired and subjected to surgeries in the tibia 2 weeks before euthanasia. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.5 mm, 3.75 mm, and 4.0 mm in final diameter. The insertion and removal torque was recorded for all samples. Statistical significance was set to 95% level of confidence and the number of dogs was considered as the statistical unit for all comparisons. For the torque and BIC and BAFO, a general linear model was employed including instrumentation technique and time in vivo as independent. Overall, the insertion torque increased as a function of drilling diameter from 4.0 mm, to 3.75 mm, to 3.5 mm, with a significant difference in torque levels between all groups (p<0.001). Statistical assessment of BIC and BAFO showed significantly higher values for the 3.75 mm (recommended) drilling group was observed relative to the other two groups (p<0.001). Different drilling dimensions resulted in variations in insertion torque values (primary stability) and different pattern of healing and interfacial remodeling was observed for the different groups. CHAPTER 3 - The present study evaluated the effect of different drilling dimensions (undersized, regular, and oversized) in the insertion and removal torques of dental implants in a beagle dog model. Six beagle dogs were acquired and subjected to bilateral surgeries in the radii 1 and 3 weeks before euthanasia. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.2 mm, 3.5 mm, and 3.8 mm in final diameter. The insertion and removal torque was recorded for all samples. Statistical analysis was performed by paired t tests for repeated measures and by t tests assuming unequal variances (all at the 95% level of significance). Overall, the insertion torque and removal torque levels obtained were inversely proportional to the drilling dimension, with a significant difference detected between the 3.2 mm and 3.5 mm relative to the 3.8 mm groups (P < 0.03). Although insertion torque–removal torque paired observations was statis- tically maintained for the 3.5 mm and 3.8 mm groups, a significant decrease in removal torque values relative to insertion torque levels was observed for the 3.2 mm group. A different pattern of healing and interfacial remodeling was observed for the different groups. Different drilling dimensions resulted in variations in insertion torque values (primary stability) and stability maintenance over the first weeks of bone healing.
Resumo:
Background: Several theories, such as the biological width formation, the inflammatory reactions due to the implant-abutment microgap contamination, and the periimplant stress/strain concentration causing bone microdamage accumulation, have been suggested to explain early periimplant bone loss. However, it is yet not well understood to which extent the implant-abutment connection type may influence the remodeling process around dental implants. Aim: to evaluate clinical, bacteriological, and biomechanical parameters related to periimplant bone loss at the crestal region, comparing external hexagon (EH) and Morse-taper (MT) connections. Materials and methods: Twelve patients with totally edentulous mandibles received four custom made Ø 3.8 x 13 mm implants in the interforaminal region of the mandible, with the same design, but different prosthetic connections (two of them EH or MT, randomly placed based on a split-mouth design), and a immediate implant- supported prosthesis. Clinical parameters (periimplant probing pocket depth, modified gingival index and mucosal thickness) were evaluated at 6 sites around the implants, at a 12 month follow-up. The distance from the top of the implant to the first bone-to-implant contact – IT-FBIC was evaluated on standardized digital peri-apical radiographs acquired at 1, 3, 6 and 12 months follow-up. Samples of the subgingival microbiota were collected 1, 3 and 6 months after implant loading. DNA were extracted and used for the quantification of Tanerella forsythia, Porphyromonas gingivalis, Aggragatibacter actinomycetemcomitans, Prevotella intermedia and Fusobacterium nucleatum. Comparison among multiple periods of observation were performed using repeated-measures Analysis of Variance (ANOVA), followed by a Tukey post-hoc test, while two-period based comparisons were made using paired t- test. Further, 36 computer-tomographic based finite element (FE) models were accomplished, simulating each patient in 3 loading conditions. The results for the peak EQV strain in periimplant bone were interpreted by means of a general linear model (ANOVA). Results: The variation in periimplant bone loss assessed by means of radiographs was significantly different between the connection types (P<0.001). Mean IT-FBIC was 1.17±0.44 mm for EH, and 0.17±0.54 mm for MT, considering all evaluated time periods. All clinical parameters presented not significant differences. No significant microbiological differences could be observed between both connection types. Most of the collected samples had very few pathogens, meaning that these regions were healthy from a microbiological point of view. In FE analysis, a significantly higher peak of EQV strain (P=0.005) was found for EH (mean 3438.65 µ∑) compared to MT (mean 840.98 µ∑) connection. Conclusions: Varying implant-abutment connection type will result in diverse periimplant bone remodeling, regardless of clinical and microbiological conditions. This fact is more likely attributed to the singular loading transmission through different implant-abutment connections to the periimplant bone. The present findings suggest that Morse-taper connection is more efficient to prevent periimplant bone loss, compared to an external hexagon connection.
Resumo:
In several areas of health professionals (pediatricians, nutritionists, orthopedists, endocrinologists, dentists, etc.) are used in the assessment of bone age to diagnose growth disorders in children. Through interviews with specialists in diagnostic imaging and research done in the literature, we identified the TW method - Tanner and Whitehouse as the most efficient. Even achieving better results than other methods, it is still not the most used, due to the complexity of their use. This work presents the possibility of automation of this method and therefore that its use more widespread. Also in this work, they are met two important steps in the evaluation of bone age, identification and classification of regions of interest. Even in the radiography in which the positioning of the hands were not suitable for TW method, the identification algorithm of the fingers showed good results. As the use AAM - Active Appearance Models showed good results in the identification of regions of interest even in radiographs with high contrast and brightness variation. It has been shown through appearance, good results in the classification of the epiphysis in their stages of development, being chosen the average epiphysis finger III (middle) to show the performance. The final results show an average percentage of 90% hit and misclassified, it was found that the error went away just one stage of the correct stage.