4 resultados para Avaliação de riscos de saude

em Universidade Federal de Uberlândia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The work is to demonstrate the scope of modern-day major regulatory provisions and the policies implemented to adoption of biofuels in the national energy matrix. The adoption of biofuels as an alternative to fossil fuels, is based on the realization of the fundamental right to an ecologically balanced environment mitigating hazards and environmental hazards arising from a postmodern society. However, the change in the Brazilian energy matrix observe the precepts of certain environmental principles to essentially environmental preservation The proposed Environmental rule of law is founded on the realization of the right (duty) key to an ecologically balanced environment for sustainable development. Thus, it is up to the State, in addition to considering the dangers and risks fruits of government decisions, present the possible instruments to mitigate the irreversible environmental damage to the environment. The management of environmental risks present in the ideals of an Environmental rule of law, plays an important role in the preservation and economic development, using, therefore, of acautelatórios legal instruments, such as environmental licensing and the ecological-economic zoning, measures adopted in the light of the principles of precaution and preservation. The adoption of research in the environmental field, improvement and development of environmental technology, building a system to observe ecological changes, imposition of environmental policy objectives to be achieved in the medium and long term and systematization of organizations plan a protection policy environmental, are essential measures to control possible environmental risks and damage guided by the aforementioned environmental principles. Thus, it will be used the inductive method of approach, starting from the analysis of the new perspective of Environmental rule of law and the implementation of biofuels in the context of a post-modern society, marked by uncertainty and the risk of damage, from the study of the principles of caution, maintaining and cautionary measures in mitigating the hazards and potential risks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The past few decades have brought many changes to the dental practice and the technology has become ready available. The result of a satisfactory rehabilitation treatment basically depends on the balance between biological and mechanical factors. The marginal adaptation of crowns and prosthetic structures is vital factor for long-term success. The development of CAD / CAM technology in the manufacture of dental prostheses revolutionized dentistry, this technology is capable of generating a virtual model from the direct digital scanning from the mouth, casts or impressions. It allows the planning and design of the structure in a computered software. The virtual projects are obtained with high precision and a significant reduction in clinical and laboratory time. Thus, the present study (Chapters 1, 2 and 3) computed microtomography was used to evaluate, different materials, different CAD/CAM systems, different ways of obtaining virtual model (with direct or indirect scanning), and in addition, also aims to evaluate the influence of cementing agent in the final adaptation of crowns and copings obtained by CAD / CAM. Furthermore, this study (Chapter 4, 5 and 6) also aims to evaluate significant differences in vertical and horizontal misfits in abutment-free frameworks on external hexagon implants (HE) using full castable UCLAs, castable UCLAs with cobalt-chromium pre-machined bases and obtained by CAD / CAM with CoCr or Zirconia by different scanning and milling systems. For this, the scanning electron microscopy and interferometry were used. It was concluded that the CAD / CAM technology is capable to produce restorations, copings and screw-retained implant-supported frameworks in different materials and systems offering satisfactory results of marginal accuracy, with significative reduction in clinical and laboratory time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Several theories, such as the biological width formation, the inflammatory reactions due to the implant-abutment microgap contamination, and the periimplant stress/strain concentration causing bone microdamage accumulation, have been suggested to explain early periimplant bone loss. However, it is yet not well understood to which extent the implant-abutment connection type may influence the remodeling process around dental implants. Aim: to evaluate clinical, bacteriological, and biomechanical parameters related to periimplant bone loss at the crestal region, comparing external hexagon (EH) and Morse-taper (MT) connections. Materials and methods: Twelve patients with totally edentulous mandibles received four custom made Ø 3.8 x 13 mm implants in the interforaminal region of the mandible, with the same design, but different prosthetic connections (two of them EH or MT, randomly placed based on a split-mouth design), and a immediate implant- supported prosthesis. Clinical parameters (periimplant probing pocket depth, modified gingival index and mucosal thickness) were evaluated at 6 sites around the implants, at a 12 month follow-up. The distance from the top of the implant to the first bone-to-implant contact – IT-FBIC was evaluated on standardized digital peri-apical radiographs acquired at 1, 3, 6 and 12 months follow-up. Samples of the subgingival microbiota were collected 1, 3 and 6 months after implant loading. DNA were extracted and used for the quantification of Tanerella forsythia, Porphyromonas gingivalis, Aggragatibacter actinomycetemcomitans, Prevotella intermedia and Fusobacterium nucleatum. Comparison among multiple periods of observation were performed using repeated-measures Analysis of Variance (ANOVA), followed by a Tukey post-hoc test, while two-period based comparisons were made using paired t- test. Further, 36 computer-tomographic based finite element (FE) models were accomplished, simulating each patient in 3 loading conditions. The results for the peak EQV strain in periimplant bone were interpreted by means of a general linear model (ANOVA). Results: The variation in periimplant bone loss assessed by means of radiographs was significantly different between the connection types (P<0.001). Mean IT-FBIC was 1.17±0.44 mm for EH, and 0.17±0.54 mm for MT, considering all evaluated time periods. All clinical parameters presented not significant differences. No significant microbiological differences could be observed between both connection types. Most of the collected samples had very few pathogens, meaning that these regions were healthy from a microbiological point of view. In FE analysis, a significantly higher peak of EQV strain (P=0.005) was found for EH (mean 3438.65 µ∑) compared to MT (mean 840.98 µ∑) connection. Conclusions: Varying implant-abutment connection type will result in diverse periimplant bone remodeling, regardless of clinical and microbiological conditions. This fact is more likely attributed to the singular loading transmission through different implant-abutment connections to the periimplant bone. The present findings suggest that Morse-taper connection is more efficient to prevent periimplant bone loss, compared to an external hexagon connection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Ventilator-associated pneumonia (VAP) is a health care related infection and the second leading cause of nosocomial infections linked to morbidity and mortality rates. Therefore, the implementation of care guideline protocols has become necessary for critically ill patients in ICUs in order to provide adequate treatment. Objective: To assess the impact of a package called FAST HUG in PAV ; analyze the risk factors for occurrence of VAP in adult patients at an ICU of a private hospital ; analyze the clinical characteristics of patients who were or were not submitted to the FAST HUG ; analyze the etiology of microorganisms related to EPI ; determine the cost of hospitalization in patients with pneumonia and in patients who received the FAST HUG.Methods: The study was performed in a private hospital that has an 8-bed ICU. It was divided into two phases: before implementing FAST HUG, from August 2011 to August 2012 and after the implementation of FAST HUG, from September 2012 to December 2013. An individual form for each patient in the study was filled out by using information taken electronically from the hospital medical records. The following data for each patient was obtained: age, gender, reason for hospitalization, the use of three or more types of antibiotics, length of stay, intubation time and progress. Findings: After the implementation of FAST HUG, there was an observable decrease in the occurrence of VAP (p <0.01), as well as a reduction in mortality rates (p <0.01). It also shows that the intervention performed in the study resulted in a significant reduction in ICU hospital costs (p <0.05).Conclusion: The implementation of FAST HUG reduced the cases of VAP. Thus, decreasing costs, reducing mortality rates and length of stay, which therefore resulted in an improvement to the overall quality of care.