2 resultados para <10 mm
em Universidade Federal de Uberlândia
Resumo:
CHAPTER II - The Chrysocyon brachyurus is the biggest South American canid which has a high frequency of dental injuries, both in wild and captivity. Thus, veterinary procedures are necessary to preserve the feeding capacity of hundreds of captive specimens worldwide. The aim of this study was to study the mandibular morphometry of maned wolf with emphasis on the establishment of anatomic references to the anesthetic blockage of the inferior alveolar and mental nerves. Therefore, 15 measurements in 22 hemimandibles of C. brachyurus adults were taken. For extra-oral technique of blockage of the inferior alveolar nerve at the level of the mandibular foramen, it is stated that the needle should be advanced, close to the medial surface of the mandibular ramus, by 11.4 mm perpendiculary from the palpable concavity. Alternatively, the needle can be introduced for 30.4 mm from the angular process at 20-25 degrees angle with the ventral margin. For blocking only the mentual nerve, it is recommended the introduction of needle for 10 mm, close to the lateral aspect of the mandibular body, at the level of the lower first premolar. The mandibular foramen showed similars position, size and symmetry in the maned wolfs specimens examined. The comparison of the data with those available for other carnivores reflects the necessity for determining these anatomical references specifically for each species.
Resumo:
CHAPTER 1 - This study histologically evaluated two implant designs: a classic thread design versus another specifically designed for healing chamber formation placed with two drilling protocols. Forty dental implants (4.1 mm diameter) with two different macrogeometries were inserted in the tibia of 10 Beagle dogs, and maximum insertion torque was recorded. Drilling techniques were: until 3.75 mm (regular-group); and until 4.0 mm diameter (overdrillinggroup) for both implant designs. At 2 and 4 weeks, samples were retrieved and processed for histomorphometric analysis. For torque and BIC (bone-to-implant contact) and BAFO (bone area fraction occupied), a general-linear model was employed including instrumentation technique and time in vivo as independent. The insertion torque recorded for each implant design and drilling group significantly decreased as a function of increasing drilling diameter for both implant designs (p<0.001). No significant differences were detected between implant designs for each drilling technique (p>0.18). A significant increase in BIC was observed from 2 to 4 weeks for both implants placed with the overdrilling technique (p<0.03) only, but not for those placed in the 3.75 mm drilling sites (p>0.32). Despite the differences between implant designs and drilling technique an intramembranous-like healing mode with newly formed woven bone prevailed. CHAPTER 2 - The objective of this preliminary histologic study was to determine whether the alteration of drilling protocols (oversized, intermediate, undersized drilling) present different biologic responses at early healing periods of 2 weeks in vivo in a beagle dog model. Ten beagle dogs were acquired and subjected to surgeries in the tibia 2 weeks before euthanasia. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.5 mm, 3.75 mm, and 4.0 mm in final diameter. The insertion and removal torque was recorded for all samples. Statistical significance was set to 95% level of confidence and the number of dogs was considered as the statistical unit for all comparisons. For the torque and BIC and BAFO, a general linear model was employed including instrumentation technique and time in vivo as independent. Overall, the insertion torque increased as a function of drilling diameter from 4.0 mm, to 3.75 mm, to 3.5 mm, with a significant difference in torque levels between all groups (p<0.001). Statistical assessment of BIC and BAFO showed significantly higher values for the 3.75 mm (recommended) drilling group was observed relative to the other two groups (p<0.001). Different drilling dimensions resulted in variations in insertion torque values (primary stability) and different pattern of healing and interfacial remodeling was observed for the different groups. CHAPTER 3 - The present study evaluated the effect of different drilling dimensions (undersized, regular, and oversized) in the insertion and removal torques of dental implants in a beagle dog model. Six beagle dogs were acquired and subjected to bilateral surgeries in the radii 1 and 3 weeks before euthanasia. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.2 mm, 3.5 mm, and 3.8 mm in final diameter. The insertion and removal torque was recorded for all samples. Statistical analysis was performed by paired t tests for repeated measures and by t tests assuming unequal variances (all at the 95% level of significance). Overall, the insertion torque and removal torque levels obtained were inversely proportional to the drilling dimension, with a significant difference detected between the 3.2 mm and 3.5 mm relative to the 3.8 mm groups (P < 0.03). Although insertion torque–removal torque paired observations was statis- tically maintained for the 3.5 mm and 3.8 mm groups, a significant decrease in removal torque values relative to insertion torque levels was observed for the 3.2 mm group. A different pattern of healing and interfacial remodeling was observed for the different groups. Different drilling dimensions resulted in variations in insertion torque values (primary stability) and stability maintenance over the first weeks of bone healing.