6 resultados para weak power grids

em Aston University Research Archive


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Four-leg dc-ac power converters are widely used for the power grids to manage grid voltage unbalance caused by the interconnection of single-phase or three-phase unbalanced loads. These converters can further be connected in parallel to increase the overall power rating. The control of these converters poses a particular challenge if they are placed far apart with no links between them (e.g., in islanded microgrids). This challenge is studied in this paper with each four-leg converter designed to have improved common current sharing and selective voltage-quality enhancement. The common current sharing, including zero sequence component, is necessary since loads are spread over the microgrid and they are hence the common responsibility of all converters. The voltage-quality enhancement consideration should however be more selective since different loads have different sensitivity levels towards voltage disturbances. Converters connected to the more sensitive load buses should therefore be selectively triggered for compensation when voltage unbalances at their protected buses exceed the predefined thresholds. The proposed scheme is therefore different from conventional centralized schemes protecting only a common bus. Simulation and experimental results obtained have verified the effectiveness of the proposed scheme when applied to a four-wire islanded microgrid.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Many important problems in communication networks, transportation networks, and logistics networks are solved by the minimization of cost functions. In general, these can be complex optimization problems involving many variables. However, physicists noted that in a network, a node variable (such as the amount of resources of the nodes) is connected to a set of link variables (such as the flow connecting the node), and similarly each link variable is connected to a number of (usually two) node variables. This enables one to break the problem into local components, often arriving at distributive algorithms to solve the problems. Compared with centralized algorithms, distributed algorithms have the advantages of lower computational complexity, and lower communication overhead. Since they have a faster response to local changes of the environment, they are especially useful for networks with evolving conditions. This review will cover message-passing algorithms in applications such as resource allocation, transportation networks, facility location, traffic routing, and stability of power grids.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There has been negligible adoption of combined heat and power (CHP) for district heating (DH) in Britain, despite continued advocacy. This thesis constructs an account of the treatment of the option, and devises a framework for explanation. Analysis of technological development and adoption, it is argued, should be similar to that of other social processes, and be subject to the same requirements and criticisms. They will, however, show features peculiar to the institutions developing and selecting technologies, their relation to different social groups, and the forms of knowledge in and about technology. Conventional approaches - organisation and interorganisation theories, and analyses of policy-making - give useful insights but have common limitations. Elements of an analytical framework situating detailed issues and outcomes in a structured historical context are derived from convergent radical critiques. Thus activity on CHP/DH is essentially shaped by the development and relations of energy sector institutions: central and local government, nationalised industries and particularly the electricity industry. Analysis of them is related to the specific character of the British state. A few CHP and DH installations were tried before 1940. During postwar reconstruction, extensive plans for several cities were abandoned or curtailed. In the 1960s and 70s, many small non-CHP DH schemes were installed on housing estates. From the mid-70s, the national potential of CHP/DH has been reappraised, with widespread support and favourable evaluations, but little practical progress. Significant CHP/DH adoption is shown to have been systematically excluded ultimately by the structure of energy provision; centralised production interests dominate and co-ordination is weak. Marginal economics and political commitment have allowed limited development in exceptional circumstances. Periods of upheaval provided greater opportunity and incentive for CHP/DH but restructuring eventually obstructed it. Explanation of these outcomes is shown to require analysis at several levels, from broad context to detailed action.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report for the first time on the limitations in the operational power range of few-mode fiber based transmission systems, employing 28Gbaud quadrature phase shift keying transponders, over 1,600km. It is demonstrated that if an additional mode is used on a preexisting few-mode transmission link, and allowed to optimize its performance, it will have a significant impact on the pre-existing mode. In particular, we show that for low mode coupling strengths (weak coupling regime), the newly added variable power mode does not considerably impact the fixed power existing mode, with performance penalties less than 2dB (in Q-factor). On the other hand, as mode coupling strength is increased (strong coupling regime), the individual launch power optimization significantly degrades the system performance, with penalties up to ∼6dB. Our results further suggest that mutual power optimization, of both fixed power and variable power modes, reduces power allocation related penalties to less than 3dB, for any given coupling strength, for both high and low differential mode delays. © 2013 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A scalable synthetic muscle has been constructed that transducts nanoscale molecular shape changes into macroscopic motion. The working material, which deforms affinely in response to a pH stimulus, is a self-assembled block copolymer comprising nanoscopic hydrophobic domains in a weak polyacid matrix. A device has been assembled where the muscle does work on a cantilever and the force generated has been measured. When coupled to a chemical oscillator this provides a free running chemical motor that generates a peak power of 20 mW kg 1 by the serial addition of 10 nm shape changes that scales over 5 orders of magnitude. It is the nanostructured nature of the gel that gives rise to the affine deformation and results in a robust working material for the construction of scalable muscle devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Communication between power converters is vital for high performance DC micro-grids controls. However, for residential DC micro-grid applications, using external communication link would increase the system cost, and reduce the system flexibility and reliability. This paper presents a novel method to enable the conventional DC/DC converters to transmit data via the common DC Bus. With this technology, cost-effective low bandwidth communication links between power converters can be established within a DC micro-grid, and advanced distributed control algorithms can be developed. A reliable communication with 2 kbps transmission rate has been implemented between the Boost converters through the common input DC bus.