12 resultados para visual pop-out
em Aston University Research Archive
Resumo:
The ability to distinguish one visual stimulus from another slightly different one depends on the variability of their internal representations. In a recent paper on human visual-contrast discrimination, Kontsevich et al (2002 Vision Research 42 1771 - 1784) re-considered the long-standing question whether the internal noise that limits discrimination is fixed (contrast-invariant) or variable (contrast-dependent). They tested discrimination performance for 3 cycles deg-1 gratings over a wide range of incremental contrast levels at three masking contrasts, and showed that a simple model with an expansive response function and response-dependent noise could fit the data very well. Their conclusion - that noise in visual-discrimination tasks increases markedly with contrast - has profound implications for our understanding and modelling of vision. Here, however, we re-analyse their data, and report that a standard gain-control model with a compressive response function and fixed additive noise can also fit the data remarkably well. Thus these experimental data do not allow us to decide between the two models. The question remains open. [Supported by EPSRC grant GR/S74515/01]
Resumo:
Gamma activity in the visual cortex has been reported in numerous EEG studies of coherent and illusory figures. A dominant theme of many such findings has been that temporal synchronization in the gamma band in response to these identifiable percepts is related to perceptual binding of the common features of the stimulus. In two recent studies using magnetoencephalography (MEG) and the beamformer analysis technique, we have shown that the magnitude of induced gamma activity in visual cortex is dependent upon independent stimulus features such as spatial frequency and contrast. In particular, we showed that induced gamma activity is maximal in response to gratings of 3 cycles per degree (3 cpd) of high luminance contrast. In this work, we set out to examine stimulus contrast further by using isoluminant red/green gratings that possess color but not luminance contrast using the same cohort of subjects. We found no induced gamma activity in V1 or visual cortex in response to the isoluminant gratings in these subjects who had previously shown strong induced gamma activity in V1 for luminance contrast gratings.
Resumo:
Since much knowledge is tacit, eliciting knowledge is a common bottleneck during the development of knowledge-based systems. Visual interactive simulation (VIS) has been proposed as a means for eliciting experts’ decision-making by getting them to interact with a visual simulation of the real system in which they work. In order to explore the effectiveness and efficiency of VIS based knowledge elicitation, an experiment has been carried out with decision-makers in a Ford Motor Company engine assembly plant. The model properties under investigation were the level of visual representation (2-dimensional, 2½-dimensional and 3-dimensional) and the model parameter settings (unadjusted and adjusted to represent more uncommon and extreme situations). The conclusion from the experiment is that using a 2-dimensional representation with adjusted parameter settings provides the better simulation-based means for eliciting knowledge, at least for the case modelled.
Resumo:
Since the visual evoked potential to pattern reversal stimulation produces a paradoxical lateralisation of the major positive P100 component and since this paradoxical lateralisation is dependent on the stimulus parameters including check and field size, we have therefore, carried out a study of the magnetic response (VEMR) to a pattern reversal stimulus in four normal subjects using both full field and half field stimulation and two different check sizes.
Resumo:
Distributed source analyses of half-field pattern onset visual evoked magnetic responses (VEMR) were carried out by the authors with a view to locating the source of the largest of the components, the CIIm. The analyses were performed using a series of realistic source spaces taking into account the anatomy of the visual cortex. Accuracy was enhanced by constraining the source distributions to lie within the visual cortex only. Further constraints on the source space yielded reliable, but possibly less meaningful, solutions.
Resumo:
There are two aspects of PD of particular interest to optometrists. First, PD patients can develop a range of visual problems including those affecting eye movement, pupillary function, and in complex visual functions involving the ability to judge distance or make out the shape of an object. Second, the symptoms of PD can be treated successfully using a variety of drugs, some of which have significant ocular adverse reactions (OAR). This article describes the general features of PD, the dopamine neurotransmitter system and its relevance to eye symptoms, the visual symptoms reported in PD, and the OAR that have been reported.
Resumo:
The aim of this research was to determine the effect of a lutein-based nutritional supplemented on measures of visual function in normal and ARMD-affected eyes. Thirty participants were recruited to the ARMD cohort (aged between 55 and 82 years, mean ± SD: 69.2 ± 7.8) and 46 were recruited into the normal cohort (aged between 22 and 73 years, mean ± SD: 50.0 ± 15.9). Outcome measures were distance (DVA) and near (NVA) visual acuity, contrast sensitivity (CS), photostress recovery time measured with the Eger Macular Stressometer (EMS), central visual function assessed with the Macular Mapping test (MMT), and fundus photography. Reliability studies were carried out for the EMS and the MMT. A change of 14 s is required to indicate a clinically significant change in EMS time, and a change of 14 MMT points is required to indicate a clinically significant change in MMT score. Sample sizes were sufficient for the trial to have 80% power to detect a significant clinical effect at the 5% significance level for all outcome measures in the normal cohort, and for CS in the ARMD cohort. The study demonstrated that a nutritional supplement containing 6mg lutein, 750 mg vitamin A, 250 mg vitamin C, 34 mg vitamin E, 10 mg zinc, and 0.5 mg copper had no effect on the outcome measures over nine or 18 months in normal or ARMD affected participants. The finding that nine months of antioxidant supplementation, in this case, has no significant effect on CS in ARMD-affected participants adds to the literature, and contrasts with previous RCTs, the AREDS and the LAST. This project has added to the debate about the use of nutritional supplementation prior to the onset of ARMD.
Resumo:
The processing conducted by the visual system requires the combination of signals that are detected at different locations in the visual field. The processes by which these signals are combined are explored here using psychophysical experiments and computer modelling. Most of the work presented in this thesis is concerned with the summation of contrast over space at detection threshold. Previous investigations of this sort have been confounded by the inhomogeneity in contrast sensitivity across the visual field. Experiments performed in this thesis find that the decline in log contrast sensitivity with eccentricity is bilinear, with an initial steep fall-off followed by a shallower decline. This decline is scale-invariant for spatial frequencies of 0.7 to 4 c/deg. A detailed map of the inhomogeneity is developed, and applied to area summation experiments both by incorporating it into models of the visual system and by using it to compensate stimuli in order to factor out the effects of the inhomogeneity. The results of these area summation experiments show that the summation of contrast over area is spatially extensive (occurring over 33 stimulus carrier cycles), and that summation behaviour is the same in the fovea, parafovea, and periphery. Summation occurs according to a fourth-root summation rule, consistent with a “noisy energy” model. This work is extended to investigate the visual deficit in amblyopia, finding that area summation is normal in amblyopic observers. Finally, the methods used to study the summation of threshold contrast over area are adapted to investigate the integration of coherent orientation signals in a texture. The results of this study are described by a two-stage model, with a mandatory local combination stage followed by flexible global pooling of these local outputs. In each study, the results suggest a more extensive combination of signals in vision than has been previously understood.
Resumo:
Objective: The purpose of this study was to examine the effectiveness of a new analysis method of mfVEP objective perimetry in the early detection of glaucomatous visual field defects compared to the gold standard technique. Methods and patients: Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes), and glaucoma suspect patients (38 eyes). All subjects underwent two standard 24-2 visual field tests: one with the Humphrey Field Analyzer and a single mfVEP test in one session. Analysis of the mfVEP results was carried out using the new analysis protocol: the hemifield sector analysis protocol. Results: Analysis of the mfVEP showed that the signal to noise ratio (SNR) difference between superior and inferior hemifields was statistically significant between the three groups (analysis of variance, P<0.001 with a 95% confidence interval, 2.82, 2.89 for normal group; 2.25, 2.29 for glaucoma suspect group; 1.67, 1.73 for glaucoma group). The difference between superior and inferior hemifield sectors and hemi-rings was statistically significant in 11/11 pair of sectors and hemi-rings in the glaucoma patients group (t-test P<0.001), statistically significant in 5/11 pairs of sectors and hemi-rings in the glaucoma suspect group (t-test P<0.01), and only 1/11 pair was statistically significant (t-test P<0.9). The sensitivity and specificity of the hemifield sector analysis protocol in detecting glaucoma was 97% and 86% respectively and 89% and 79% in glaucoma suspects. These results showed that the new analysis protocol was able to confirm existing visual field defects detected by standard perimetry, was able to differentiate between the three study groups with a clear distinction between normal patients and those with suspected glaucoma, and was able to detect early visual field changes not detected by standard perimetry. In addition, the distinction between normal and glaucoma patients was especially clear and significant using this analysis. Conclusion: The new hemifield sector analysis protocol used in mfVEP testing can be used to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol, it can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. The sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucomatous visual field loss. The intersector analysis protocol can detect early field changes not detected by the standard Humphrey Field Analyzer test. © 2013 Mousa et al, publisher and licensee Dove Medical Press Ltd.
Resumo:
The present report reviews behavioural, electroencephalographic, and especially magnetoencephalographic findings on the cortical mechanisms underlying attentional processes that separate targets from distractors and that ensure durable target representations for goal-directed action. A common way of investigation is to observe the system’s overt and covert behaviour when capacity limitations are reached. Here we focus on the aspect of temporally enhanced processing load, namely on performance deficits occurring under rapid-serial-visual-presentation (RSVP) conditions. The most prominent of these deficits is the so-called “attentional blink” (AB) effect. We first report MEG findings with respect to the time course of activation that shows modulations around 300 ms after target onset which reflect demands and success of target consolidation. Then, findings regarding long-range inter-area phase synchronization are reported that are hypothesized to mediate communication within the attentional network. Changes in synchronization reflect changes in the attentional demands of the task and are directly related to behavioural performance. Furthermore, enhanced vigilance of the system elicits systematically increased synchronization indices. A hypothetical framework is sketched out that aims at explaining limitations in multiple target consolidation under RSVP conditions.
Resumo:
PURPOSE: Previous investigations have demonstrated a relative vascular autoregulatory inefficiency of the inferior compared to the superior retina in healthy subjects breathing increased CO2. The purpose of this study was to determine whether the superior and inferior visual field sensitivities of healthy eyes are similarly affected during mild hypercapnia. DESIGN: Experimental study. METHODS: Visual field analysis (Humphrey Field Analyser; SITA standard 24-2 program) was carried out on one randomly selected eye of 22 subjects (mean age, 27.7 ± 5 years) during normal room air breathing and isoxic hypercapnia. The Student paired t-tests were used to compare the visual field indices mean deviation (MD) and pattern standard deviation (PSD) for each breathing condition. A secondary, sectoral analysis of mean pointwise sensitivity was performed for each condition. In each case a P value of <.01 was considered statistically significant (Bonferroni corrected). RESULTS: Visual field MD was -0.23 ± 0.95dB during room air breathing and -0.49 ± 1.04dB during hypercapnia (P = .034). Sectoral pointwise mean sensitivity deteriorated by 0.46dB (P = .006) in the upper visual hemifield during hypercapnia, whereas no significant difference was observed for the lower hemifield (P = .331). CONCLUSIONS: The upper visual hemifield exhibited a significantly greater degree of deterioration in pointwise visual field mean sensitivity compared to the lower hemifield during hypercapnic conditions. This suggests that the upper visual hemifield and hence inferior retina is more susceptible to insult during hypercapnia than the superior retina in healthy individuals. A regional susceptibility of inferior retinal function to altered vascular or metabolic effects may account for the earlier and more frequent inferior nerve fibre damage associated with glaucomatous optic neuropathy. © 2003 by Elsevier Science Inc. All rights reserved.
Resumo:
Background: Vigabatrin (VGB) is an anti-epileptic medication which has been linked to peripheral constriction of the visual field. Documenting the natural history associated with continued VGB exposure is important when making decisions about the risk and benefits associated with the treatment. Due to its speed the Swedish Interactive Threshold Algorithm (SITA) has become the algorithm of choice when carrying out Full Threshold automated static perimetry. SITA uses prior distributions of normal and glaucomatous visual field behaviour to estimate threshold sensitivity. As the abnormal model is based on glaucomatous behaviour this algorithm has not been validated for VGB recipients. We aim to assess the clinical utility of the SITA algorithm for accurately mapping VGB attributed field loss. Methods: The sample comprised one randomly selected eye of 16 patients diagnosed with epilepsy, exposed to VGB therapy. A clinical diagnosis of VGB attributed visual field loss was documented in 44% of the group. The mean age was 39.3 years∈±∈14.5 years and the mean deviation was -4.76 dB ±4.34 dB. Each patient was examined with the Full Threshold, SITA Standard and SITA Fast algorithm. Results: SITA Standard was on average approximately twice as fast (7.6 minutes) and SITA Fast approximately 3 times as fast (4.7 minutes) as examinations completed using the Full Threshold algorithm (15.8 minutes). In the clinical environment, the visual field outcome with both SITA algorithms was equivalent to visual field examination using the Full Threshold algorithm in terms of visual inspection of the grey scale plots, defect area and defect severity. Conclusions: Our research shows that both SITA algorithms are able to accurately map visual field loss attributed to VGB. As patients diagnosed with epilepsy are often vulnerable to fatigue, the time saving offered by SITA Fast means that this algorithm has a significant advantage for use with VGB recipients.