15 resultados para urine reagent strip

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reaction of activated aromatics containing phenols, naphthol, methoxynaphthalenes, anisole etc. with 1-butyl-3-methylimidazolium tribromide ([Bmim]Br-3) under solvent-free conditions, selectively gave the corresponding monobromination products with excellent yields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reaction of arylamines with 1-butyl-3-methylimidazolium tribromide ([bmim]Br3) under solvent-free conditions, gave selectively the corresponding monobromination products with excellent, yields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims To date, there is no convincing evidence that non-insulin treated patients who undertake self-blood glucose monitoring (SBGM) have better glycaemic control than those who test their urine. This has led to a recommendation that non-insulin dependent patients undertake urine testing, which is the cheaper option. This recommendation does not take account of patients' experiences and views. This study explores the respective merits of urine testing and SBGM from the perspectives of newly diagnosed patients with Type 2 diabetes. Methods Qualitative study using repeat in-depth interviews with 40 patients. Patients were interviewed three times at 6-monthly intervals over 1 year. Patients were recruited from hospital clinics and general practices in Lothian, Scotland. The study was informed by grounded theory, which involves concurrent data collection and analysis. Results Patients reported strongly negative views of urine testing, particularly when they compared it with SBGM. Patients perceived urine testing as less convenient, less hygienic and less accurate than SBGM. Most patients assumed that blood glucose meters were given to those with a more advanced or serious form of diabetes. This could have implications for how they thought about their own disease. Patients often interpreted negative urine results as indicating that they could not have diabetes. Conclusions Professionals should be aware of the meanings and understandings patients attach to the receipt and use of different types of self-monitoring equipment. Guidelines that promote the use of consistent criteria for equipment allocation are required. The manner in which negative urine results are conveyed needs to be reconsidered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The levels of neopterin, biopterin and the neopterin/biopterin ratio (N/B) were measured in urine samples taken from normal young and elderly control subjects, exceptionally healthy elderly control subjects classified according to the ‘Senieur’ protocol and patients with Down’s syndrome (DS) or Alzheimer’s disease (AD). The N/B ratio was approximately unity in control groups with the exception of the normal elderly controls. The levels of neopterin and biopterin declined with age in the exceptionally healthy ‘Senieur’ control group. The N/B ratio was elevated in young and old DS patients as a result of the significant increase in neopterin. Neopterin levels were significantly elevated in AD patients compared with the healthy elderly controls, but this did not result in a significant increase in the N/B ratio in these patients. The N/B ratio increased with age in AD patients as a result of a decline in biopterin. These results suggested that there is a cellular immune reponse in DS and AD patients which in DS, may precede the formation of beta-amyloid deposits in the brain. In addition, there may be a deficiency in tetrahydrobiopterin biosynthesis in AD which becomes more marked with age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urine proteomics is emerging as a powerful tool for biomarker discovery. The purpose of this study is the development of a well-characterized "real life" sample that can be used as reference standard in urine clinical proteomics studies.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rise of male strip shows marketed towards heterosexual women has called into question the idea that only men can 'gaze' or be 'sexual scrutinizers' in public leisure spaces. This paper details the findings of an ethnographic study of a male strip event 'Cheeky's',1 located in the Midlands, England. Utilising observation, informal interviews and photography, the paper describes the physical environment and the atmosphere of the event, and analyses interview data with female customers. The paper questions what spaces such as Cheeky's mean for female sexualities, sexual roles and desires. The findings are twofold. On the one hand the club was a relatively novel sexual space, as some women spectators experienced it as an 'empowering' space in which they could be 'sexually aggressive'; on the other hand, the character of the club was actively and adeptly manufactured by the Master of Ceremonies (MC), and male dancers, so as to encourage - and even to coercively elicit - extrovert behaviour from women customers. Despite shifting normative gendered expectations of women's sexual behaviour to some extent, ultimately the club structured women's sexual experiences around traditional heterosexist lines. The club did not encourage women's autonomous sexual expression, and many women claimed they had not found it a very 'sexy space'. © 2011 Taylor & Francis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper seeks to characterise the gendered and sexualised power relations of both female and male strip clubs, and to signal what this means for establishing positive definitions of female desire. It is argued that while it is not useful to present female strippers, or female patrons of male strip clubs as purely passive victims of male heterosexism within these venues, it is equally damaging to assume that these venues represent a whole-scale challenge to conventional oppressive gender and sexual relations for women. Some research has even suggested that both strippers and their patrons are engaged in a 'mutually exploitative' power relationship. Moreover, further empirical research documents key points where female dancers have perhaps wielded 'more' power over patrons at certain moments, and female dancers have highlighted feelings of empowerment and highlighted potential for gender and sexual relations which position women as passive to be subverted within stripping. However, such feelings are often temporally specific and are not applicable to all women in the strip industry. It may be particularly hard for these to manifest in women concentrated in the least economically-rewarding areas of the industry who have less 'power' to resist compromising their bodily boundaries. Furthermore, it is argued that women watching male strippers does little to reverse the 'male gaze', and nor does this male occupation carry as much negative social stigma with it as female stripping suffers. It is thus argued that the overwhelming picture, stemming largely from accounts of former dancers and from empirical studies of individual clubs, suggests these venues in fact do very little to challenge normative hetero-oppressive sexual scripts.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY SERVICES WITH PRIOR ARRANGEMENT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate OneTouch® Verio™ test strip performance at hypoglycaemic blood glucose (BG) levels (<3.9mmol/L [<70mg/dL]) at seven clinical studies. Methods: Trained clinical staff performed duplicate capillary BG monitoring system tests on 700 individuals with type 1 and type 2 diabetes using blood from a single fingerstick lancing. BG reference values were obtained using a YSI 2300 STAT™ Glucose Analyzer. The number and percentage of BG values within ±0.83. mmol/L (±15. mg/dL) and ±0.56. mmol/L (±10. mg/dL) were calculated at BG concentrations of <3.9. mmol/L (<70. mg/dL), <3.3. mmol/L (<60. mg/dL), and <2.8. mmol/L (<50. mg/dL). Results: At BG concentrations <3.9. mmol/L (<70. mg/dL), 674/674 (100%) of meter results were within ±0.83. mmol/L (±15. mg/dL) and 666/674 (98.8%) were within ±0.56. mmol/L (±10. mg/dL) of reference values. At BG concentrations <3.3. mmol/L (<60. mg/dL), and <2.8. mmol/L (<50. mg/dL), 358/358 (100%) and 270/270 (100%) were within ±0.56. mmol/L (±10. mg/dL) of reference values, respectively. Conclusion: In this analysis of data from seven independent studies, OneTouch Verio test strips provide highly accurate results at hypoglycaemic BG levels. © 2012 Elsevier Ireland Ltd.