3 resultados para trialling

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Atrial fibrillation (AF) is the most common heart arrhythmia and is associated with an increased risk of stroke. Stroke risk is commonly treated with oral anticoagulation (OAC) with a narrow therapeutic range (INR 2.0 to 3.0); which is poorly controlled in practice. Barriers to adherence include poor knowledge, and inaccurate perceptions surrounding illness and medications. Trial registration: ISRCTN93952605. Systematic review: Seven trials of educational, self-monitoring and decision aid interventions were included in a systematic review. Pooled analysis suggested education OR, 95% CI 7.89 (5.54-10.24) and self monitoring OR (95% CI) 5.47(2.55-8.39) significantly improve TTR; whereas decision aids are no more effective in reducing decision conflict than usual care, OR (95% CI) -0.10 (-0.17 to -0.02). Intervention development: The intervention was theoretically-driven (utilising the common sense and beliefs about medication models) and developed with expert patient feedback. Described using behavioural change techniques, the one-off group session included an educational booklet, ‘expert-patient’ focussed DVD, and worksheet. Methods: Ninety seven warfarin-naïve AF patients were randomised to receive the intervention (n=43), or usual care (n=54). The primary endpoint was time within therapeutic range (TTR), secondary endpoints included knowledge, quality of life (AF-QoL-18), beliefs about medication (BMQ), illness perceptions (IPQ-B), and anxiety and depression (HADS). Results: Intervention group had significantly higher TTR than usual care (78.5% vs. 66.7%; p=0.01). Knowledge changed significantly across time (F (3, 47) = 6.4; p<0.01), but not between groups (F (1, 47) = 3.3; p = 0.07). At six months knowledge predicted TTR (r=0.245; p=0.04). Illness concern negatively correlated with TTR (r= - 0.199; p=0.05). General Harm scores at one month predicted TTR (F (1, 72) = 4.08; p=0.048). There were significant differences in emotional representations (F (3, 49) = 3.3 (3, 49); p= 0.03), anxiety (F (3, 46) = 25.2; p<0.01) and depression (F (3, 46) = 37.7; p<0.01) across time. Conclusion: A theory-driven educational intervention can improve TTR in AF patients and potentially reduce the risk of adverse clinical outcomes. Improving education provision for AF patients is essential to ensure efficacious treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study explores the ongoing pedagogical development of a number of undergraduate design and engineering programmes in the United Kingdom. Observations and data have been collected over several cohorts to bring a valuable perspective to the approaches piloted across two similar university departments while trialling a number of innovative learning strategies. In addition to the concurrent institutional studies the work explores curriculum design that applies the principles of Co-Design, multidisciplinary and trans disciplinary learning, with both engineering and product design students working alongside each other through a practical problem solving learning approach known as the CDIO learning initiative (Conceive, Design Implement and Operate) [1]. The study builds on previous work presented at the 2010 EPDE conference: The Effect of Personality on the Design Team: Lessons from Industry for Design Education [2]. The subsequent work presented in this paper applies the findings to mixed design and engineering team based learning, building on the insight gained through a number of industrial process case studies carried out in current design practice. Developments in delivery also aligning the CDIO principles of learning through doing into a practice based, collaborative learning experience and include elements of the TRIZ creative problem solving technique [3]. The paper will outline case studies involving a number of mixed engineering and design student projects that highlight the CDIO principles, combined with an external industrial design brief. It will compare and contrast the learning experience with that of a KTP derived student project, to examine an industry based model for student projects. In addition key areas of best practice will be presented, and student work from each mode will be discussed at the conference.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To determine the utility of a range of clinical and non-clinical indicators to aid the initial selection of the optimum presbyopic contact lens. In addition, to assess whether lens preference was influenced by the visual performance compared to the other designs trialled (intra-subject) or compared to participants who preferred other designs (inter-subject). METHODS: A double-masked randomised crossover trial of Air Optix Aqua multifocal, PureVision 2 for Presbyopia, Acuvue OASYS for Presbyopia, Biofinity multifocal and monovision was conducted on 35 presbyopes (54.3±6.2years). Participant lifestyle, personality, pupil characteristics and aberrometry were assessed prior to lens fitting. After 4 weeks of wear, high and low contrast visual acuity (VA) under photopic and mesopic conditions, reading speed, Near Activity Visual Questionnaire (NAVQ) rating, subjective quality-of-vision scoring, defocus curves, stereopsis, halometry, aberrometry and ocular physiology were quantified. RESULTS: After trialling all the lenses, preference was mixed (n=12 Biofinity, n=10 monovision, n=7 Purevision, n=4 Air Optix Aqua, n=2 Oasys). Lens preference was not dependent on personality (F=1.182, p=0.323) or the hours spent working at near (p=0.535) or intermediate (p=0.759) distances. No intersubject or strong intrasubject relationships emerged between lens preference and reading speed, NAVQ rating, halo size, aberrometry or ocular physiology (p>0.05). CONCLUSIONS: Participant lifestyle and personality, ocular optics, contact lens visual performance and ocular physiology provided poor indicators of the preferred lens type after 4 weeks of wear. This is confounded by the wide range of task visual demands of presbyopes and the limited optical differences between current multifocal contact lens designs.