6 resultados para thermal radiation
em Aston University Research Archive
Resumo:
The ability to measure ocular surface temperature (OST) with thermal imaging offers potential insight into ocular physiology that has been acknowledged in the literature. The TH7102MX thermo-camera (NEC San-ei, Japan) continuously records dynamic information about OST without sacrificing spatial resolution. Using purpose-designed image analysis software, it was possible to select and quantify the principal components of absolute temperature values and the magnitude plus rate of temperature change that followed blinking. The techniques was examined for repeatability, reproducibility and the effects of extrinsic factors: a suitable experimental protocol was thus developed. The precise source of the measured thermal radiation has previously been subject toe dispute: in this thesis, the results of a study examining the relationships between physical parameters of the anterior eye and OST, confirmed a principal role for the tear film in OST. The dynamic changes in OST were studied in a large group of young subjects: quantifying the post-blink changes in temperature with time also established a role for tear flow dynamics in OST. Using dynamic thermography, the effects of hydrogel contact lens wear on OST were investigated: a model eye for in vivo work, and both neophyte and adapted contact lens wearers for in vivo studies. Significantly greater OST was observed in contact lens wearers, particularly with silicone hydrogel lenses compared to etafilcon A, and tended to be greatest when lenses had been worn continuously. This finding is important to understanding the ocular response to contact lens wear. In a group of normal subjects, dynamic thermography appeared to measure the ocular response to the application of artificial tear drops: this may prove to be a significant research and clinical tool.
Resumo:
The spectral properties of long-period gratings (LPGs) fabricated in photonic crystal fibers using femtosecond laser pulses by the point-by-point technique, without oil-immersion of the fiber, are investigated in detail. Postfabrication spectral monitoring at room temperature showed significant long-term instability of the gratings and stable spectra only after 600 h. The stabilized spectral properties of the gratings improved with increasing annealing temperature. The observed changes in resonant wavelength, optical strength, and grating birefringence were correlated to the laser inscription energy and were further used to study the mechanism of femtosecond inscription. Furthermore, the femtosecond-laser inscribed LPGs were compared to electric-arc fabricated LPGs. Comparison of experimental results with theoretical models of LPGs and laser propagation during inscription indicate that the major processes responsible for the index change are permanent compaction and thermally induced strain, the latter can be significantly changed through annealing. © 2011 Optical Society of America.
Resumo:
The interaction of ionising radiation with polymers is described and the literature relating; to the effects on polypropylene is reviewed. Oxidative and free radical reactions are discussed with particular reference to post-irradiationeffects.Isotactic and atactic polypropylene were δ and electron irradiated to doses of up to 20 megarad. Irradiations weremainly made in air. A series of other polymers were also irradiated in a preliminary survey. Molar mass measurements are used to measure the radiationyield for chain scission G (s). Irradiation at room temperature causes significantly more chain scission than at 195K. Additional chain scission occurs on storage following irradiation at 195 K. Free radical concentrations are determined by electron spin resonance, and the decay rates measured. The radical formed in air is a peroxy radical and in vacuo is a hydrocarbon radical. At77K in vacuo the radical is -CH2 - C* (CH3) - CH2 - but additional radicals are produced on warning to room temperature. The effects of increasing tenparature on radicals formed in air are described. Electron spin resonance studies on atactic polypropylene,and isotactic polypropylene in hydrogen, sulphur dioxide and nitric oxide are reported.. The melting temperatures, spherulite growth rates, and isothermal crystallisation rates of irradiated polypropylene are compared to those of the non-irradiated polymer. Crystallisation is found to proceed with an Avrami integer n = 2. At a given crystallisation temperature, the overall crystallisation rate of irradiated polymer is less than the non-irradiated, but spherulite growth rates are identical. Thermogravimetric analysis is used to assess the thermal stability of irradiated polypropylene in nitrogen, air and oxygen. Hydroperoxide analysis is used to show that several molecules of oxygen are absorbed for each initial radical, and that hydroperoxides continue to be formed for a long period following irradiation. Possible solutions for minimising irradiation and post-irradiation degradation are suggested, together with some problems for further study.
Resumo:
In this paper we propose a novel type of multiple-layer photomixer based on amorphous/nano-crystalline-Si. Such a device implies that it could be possible to enhance the conversion efficiency from optical power to THz emission by increasing the absorption length and by reducing the device overheating through the use of substrates with higher thermal conductivity compared to GaAs. Our calculations show that the output power from a two-layer Si-based photomixer is at least ten times higher than that from conventional LT-GaAs photomixers at 1 THz.
Resumo:
Here we overview our work on quantum dot based THz photoconductive antennae, capable of being pumped at very high optical intensities of higher than 1W optical mean power, i.e. about 50 times higher than the conventional LT-GaAs based antennae. Apart from high thermal tolerance, defect-free GaAs crystal layers in an InAs:GaAs quantum dot structure allow high carrier mobility and ultra-short photo carrier lifetimes simultaneously. Thus, they combine the advantages and lacking the disadvantages of GaAs and LT-GaAs, which are the most popular materials so far, and thus can be used for both CW and pulsed THz generation. By changing quantum dot size, composition, density of dots and number of quantum dot layers, the optoelectronic properties of the overall structure can be set over a reasonable range-compact semiconductor pump lasers that operate at wavelengths in the region of 1.0 μm to 1.3 μm can be used. InAs:GaAs quantum dot-based antennae samples show no saturation in pulsed THz generation for all average pump powers up to 1W focused into 30 μm spot. Generated THz power is super-linearly proportional to laser pump power. The generated THz spectrum depends on antenna design and can cover from 150 GHz up to 1.5 THz.