7 resultados para similar tests

em Aston University Research Archive


Relevância:

60.00% 60.00%

Publicador:

Resumo:

If in a correlation test, one or both variables are small whole numbers, scores based on a limited scale, or percentages, a non-parametric correlation coefficient should be considered as an alternative to Pearson’s ‘r’. Kendall’s t and Spearman’s rs are similar tests but the former should be considered if the analysis is to be extended to include partial correlations. If the data contain many tied values, then gamma should be considered as a suitable test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Coronary heart disease patients have to learn to manage their condition to maximise quality of life and prevent recurrence or deterioration. They may develop their own informal methods of self-management in addition to the advice they receive as part of formal cardiac rehabilitation programmes. This study aimed to explore the use of complementary and alternative medicines and therapies (CAM), self-test kits and attitudes towards health of UK patients one year after referral to cardiac rehabilitation. Method: Questionnaire given to 463 patients attending an assessment clinic for 12 month follow up in four West Midlands hospitals. Results: 91.1% completed a questionnaire. 29.1% of patients used CAM and/or self-test kits for self-management but few (8.9%) used both methods. CAM was more often used for treating other illnesses than for CHD management. Self-test kit use (77.2%,) was more common than CAM (31.7%,) with BP monitors being the most prevalent (80.0%). Patients obtained self-test kits from a wide range of sources, for the most part (89.5%) purchased entirely on their own initiative. Predictors of self-management were post revascularisation status and higher scores on 'holism', 'rejection of authority' and 'individual responsibility'. Predictors of self-test kit use were higher `holism' and 'individual responsibility' scores. Conclusion: Patients are independently using new technologies to monitor their cardiovascular health, a role formerly carried out only by healthcare practitioners. Post-rehabilitation patients reported using CAM for self-management less frequently than they reported using self-test kits. Reports of CAM use were less frequent than in previous surveys of similar patient groups. Automatic assumptions cannot be made by clinicians about which CHD patients are most likely to self-manage. In order to increase trust and compliance it is important for doctors to encourage all CHD patients to disclose their self-management practices and to continue to address this in follow up consultations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The initial aim of this project was to develop a non-contact fibre optic based displacement sensor to operate in the harsh environment of a 'Light Gas Gun' (LGG), which can 'fire' small particles at velocities ranging from 1-8.4 km/s. The LGG is used extensively for research in aerospace to analyze the effects of high speed impacts on materials. Ideally the measurement should be made close to the centre of the impact to minimise corruption of the data from edge effects and survive the impact. A further requirement is that it should operate at a stand-off distance of ~ 8cm. For these reasons we chose to develop a pseudo con-focal intensity sensor, which demonstrated resolution comparable with conventional PVDF sensors combined with high survivability and low cost. A second sensor was developed based on 'Fibre Bragg Gratings' (FBG) which although requiring contact with the target the low weight and very small contact area had minimal effect on the dynamics of the target. The FBG was mounted either on the surface of the target or tangentially between a fixed location. The output signals from the FBG were interrogated in time by a new method. Measurements were made on composite and aluminium plates in the LGG and on low speed drop tests. The particle momentum for the drop tests was chosen to be similar to that of the particles used in the LGG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An international round robin study of the viscosity measurements and aging of fast pyrolysis bio-oil has been undertaken recently, and this work is an outgrowth from that effort. Two bio-oil samples were distributed to two laboratories for accelerated aging tests and to three laboratories of long-term aging studies. The accelerated aging test was defined as the change in viscosity of a sealed sample of bio-oil held for 24 h at 80 °C. The test was repeated 10 times over consecutive days to determine the intra-laboratory repeatability of the method. Other bio-oil samples were placed in storage at three temperatures, 21, 5, and -17 °C, for a period of up to 1 year to evaluate the change in viscosity. The variation in the results of the accelerated aging test was shown to be low within a given laboratory. The long-term aging studies showed that storage of a filtered bio-oil under refrigeration can minimize the amount of change in viscosity. The accelerated aging test gave a measure of change similar to that of 6-12 months of storage at room temperature for a filtered bio-oil. Filtration of solids was identified as a key contributor to improving the stability of the bio-oil as expressed by the viscosity based on results of the accelerated aging tests as well as long-term aging studies. Only the filtered bio-oil consistently gave useful results in the accelerated aging and long-term aging studies. The inconsistency suggests that better protocols need to be developed for sampling bio-oils. These results can be helpful in setting standards for use of bio-oil, which is just coming into the marketplace. © 2012 American Chemical Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Today's market conditions require nonprofit leaders to act in an increasingly business-like fashion. This study asks whether NPO leaders have a similar disposition to act entrepreneurially as for-profit entrepreneurs, but hold different underlying motives. For this purpose, the study contrasts a sample of 72 leaders of nonprofit organizations with 117 entrepreneurs on their personality traits and explicit motives using standard personality tests and interviews. Both groups exhibit similar general and entrepreneurship-specific personality traits but differ significantly regarding their motivation. While nonprofit leaders' motivation stems primarily from the meaningfulness of their work; entrepreneurs are mainly motivated by the independence as well as by the income and profit provided by their work. This paper helps us understand who leaders of nonprofit organizations are.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Clogging is the main operational problem associated with horizontal subsurface flow constructed wetlands (HSSF CWs). The measurement of saturated hydraulic conductivity has proven to be a suitable technique to assess clogging within HSSF CWs. The vertical and horizontal distribution of hydraulic conductivity was assessed in two full-scale HSSF CWs by using two different in situ permeameter methods (falling head (FH) and constant head (CH) methods). Horizontal hydraulic conductivity profiles showed that both methods are correlated by a power function (FH= CH 0.7821, r 2=0.76) within the recorded range of hydraulic conductivities (0-70 m/day). However, the FH method provided lower values of hydraulic conductivity than the CH method (one to three times lower). Despite discrepancies between the magnitudes of reported readings, the relative distribution of clogging obtained via both methods was similar. Therefore, both methods are useful when exploring the general distribution of clogging and, specially, the assessment of clogged areas originated from preferential flow paths within full-scale HSSF CWs. Discrepancy between methods (either in magnitude and pattern) aroused from the vertical hydraulic conductivity profiles under highly clogged conditions. It is believed this can be attributed to procedural differences between the methods, such as the method of permeameter insertion (twisting versus hammering). Results from both methods suggest that clogging develops along the shortest distance between water input and output. Results also evidence that the design and maintenance of inlet distributors and outlet collectors appear to have a great influence on the pattern of clogging, and hence the asset lifetime of HSSF CWs. © Springer Science+Business Media B.V. 2011.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The initial aim of this project was to develop a non-contact fibre optic based displacement sensor to operate in the harsh environment of a 'Light Gas Gun' (LGG), which can 'fire' small particles at velocities ranging from 1-8.4 km/s. The LGG is used extensively for research in aerospace to analyze the effects of high speed impacts on materials. Ideally the measurement should be made close to the centre of the impact to minimise corruption of the data from edge effects and survive the impact. A further requirement is that it should operate at a stand-off distance of ~ 8cm. For these reasons we chose to develop a pseudo con-focal intensity sensor, which demonstrated resolution comparable with conventional PVDF sensors combined with high survivability and low cost. A second sensor was developed based on 'Fibre Bragg Gratings' (FBG) which although requiring contact with the target the low weight and very small contact area had minimal effect on the dynamics of the target. The FBG was mounted either on the surface of the target or tangentially between a fixed location. The output signals from the FBG were interrogated in time by a new method. Measurements were made on composite and aluminium plates in the LGG and on low speed drop tests. The particle momentum for the drop tests was chosen to be similar to that of the particles used in the LGG.