4 resultados para serum diagnosis

em Aston University Research Archive


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Sepsis continues to be a major cause of morbidity and mortality as it can readily lead tosevere sepsis, septic shock, multiple organ failure and death. The onset can be rapid and difficult to define clinically. Despite the numerous candidate markers proposed in the literature, to date a serum marker for sepsis has not been found. The aim of this study was to assay the serum of clinically diagnosed patients with eithera Gram-negative or Gram- positive bacterial sepsis for elevated levels of nine potentialmarkers of sepsis, using commercially produced enzyme linked immunosorbent assays(ELISA). The purpose was to find a test marker for sepsis that would be helpful toclinicians in cases of uncertain sepsis and consequently expose false positive BC'scaused by skin or environmental contaminants. Nine test markers were assayed including IL-6, IL-I 0, ILI2, TNF-α, lipopolysaccharide binding protein, procalcitonin, sE-selectin, sICAM -1 and a potential differential marker for Gram-positive sepsis- anti-lipid S antibody. A total of 445 patients were enrolled into this study from the Queen Elizabeth Hospital and Selly Oak Hospital (Birmingham). The results showed that all the markers were elevated in patients with sepsis and that patients with a Gram-negative sepsis consistently produced higher median/range serum levels than those with a Gram-positive sepsis. No single marker was able to identify all the septic patients. Combining two markers caused the sensitivities and specificities for a diagnosis of sepsis to increase to within a 90% to 100% range. By a process of elimination the markers that survived into the last phase were IL-6 with sICAM -1, and anti-lipid S IgG assays Defining cut-off levels for a diagnosis of sepsis became problematic and a semi-blind trial was devised to test the markers in the absence of both clinical details and positive blood cultures. Patients with pyrexia of unknown origin and negative BC were included in this phase (4). The results showed that IL-6 with sICAM-l are authentic markers of sepsis. There was 82% agreement between the test marker diagnosis and the clinical diagnosis for sepsis in patients with a Gram-positive BC and 78% agreement in cases of Gram-negative Be. In the PUO group the test markers identified 12 cases of sepsis and the clinical diagnosis 15. The markers were shown to differentiate between early sepsis and sepsis, inflammatory responses and infection. Anti-lipid S with IL-6 proved be a sensitive marker for Gram-positive infections/sepsis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Establishing the diagnosis of infective endocarditis (IE) can be difficult when blood cultures remain sterile or echocardiography is inconclusive. Staphylococcus aureus is a common aetiological microorganism in IE and is associated with severe valvular destruction and increased mortality. Early diagnosis using culture and antibiotic independent tests would be preferable to allow prompt antibiotic administration. We have developed and evaluated 2 serological assays for the rapid identification of a staphylococcal aetiology in infective endocarditis. The assays measure IgG against whole cells of S. aureus and IgG against lipid S, a novel extracellular antigen released by Gram-positive microorganisms. Methods: Serum was collected from 130 patients with IE and 94 control patients. IgG against whole cells of S. aureus and against lipid S was measured by enzyme linked immunosorbent assay (ELISA). Results: Anti-lipid S IgG titres were higher in IE caused by Gram-positive microorganisms than in controls (p < 0.0001) and higher in staphylococcal IE than in both controls and IE caused by other microorganisms (p = 0.0003). Anti-whole cell staphylococcal IgG was significantly higher in serum from patients with staphylococcal IE than in IE caused by other microorganisms and control samples (p < 0.0001). Conclusion: High anti-whole cell IgG titres are predictive of a staphylococcal aetiology in IE. Elevated serum anti-lipid S IgG titres are predictive of Gram-positive infection compared to controls, very high titres being associated with staphylococcal IE. © 2005 The British Infection Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To develop and evaluate a rapid enzyme linked immunosorbent assay (ELISA) for the diagnosis of intravascular catheter related sepsis caused by coagulase negative staphylococci. Methods: Forty patients with a clinical and microbiological diagnosis of intravascular catheter related sepsis and positive blood cultures, caused by coagulase negative staphylococci, and 40 control patients requiring a central venous catheter as part of their clinical management were recruited into the study. Serum IgG responses to a previously undetected exocellular antigen produced by coagulase negative staphylococci, termed lipid S, were determined in the patient groups by a rapid ELISA. Results: There was a significant difference (p = < 0.0001) in serum IgG to lipid S between patients with catheter related sepsis and controls. The mean antibody titre in patients with sepsis caused by coagulase negative staphylococci was 10 429 (range, no detectable serum IgG antibody to 99 939), whereas serum IgG was not detected in the control group of patients. Conclusions: The rapid ELISA offers a simple, economical, and rapid diagnostic test for suspected intravascular catheter related sepsis caused by coagulase negative staphylococci, which can be difficult to diagnose clinically. This may facilitate treatment with appropriate antimicrobials and may help prevent the unnecessary removal of intravascular catheters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The diagnosis of prosthetic joint infection and its differentiation from aseptic loosening remains problematic. The definitive laboratory diagnostic test is the recovery of identical infectious agents from multiple intraoperative tissue samples; however, interpretation of positive cultures is often complex as infection is frequently associated with low numbers of commensal microorganisms, in particular the coagulase-negative staphylococci (CNS). In this investigation, the value of serum procalcitonin (PCT), interleukin-6 (IL-6) and soluble intercellular adhesion molecule-1 (sICAM-1) as predictors of infection in revision hip replacement surgery is assessed. Furthermore, the diagnostic value of serum IgG to short-chain exocellular lipoteichoic acid (sce-LTA) is assessed in patients with infection due to CNS. Presurgical levels of conventional serum markers of infection including C-reactive protein (CRP), erythrocyte sedimentation rate (ESR) and white blood cell count (WBC) is also established. Forty-six patients undergoing revision hip surgery were recruited with a presumptive clinical diagnosis of either septic (16 patients) or aseptic loosening (30 patients). The diagnosis was confirmed microbiologically and levels of serum markers were determined. Serum levels of IL-6 and sICAM-1 were significantly raised in patients with septic loosening (P=0.001 and P=0.0002, respectively). Serum IgG to sce-LTA was elevated in three out of four patients with infection due to CNS. In contrast, PCT was not found to be of value in differentiating septic and aseptic loosening. Furthermore, CRP, ESR and WBC were significantly higher (P=0.0001, P=0.0001 and P=0.003, respectively) in patients with septic loosening. Serum levels of IL-6, sICAM-1 and IgG to sce-LTA may provide additional information to facilitate the diagnosis of prosthetic joint infection.