6 resultados para self-reference

em Aston University Research Archive


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A self-reference fiber Michelson interferometer measurement system, which employs fiber Bragg gratings (FBGs) as in-fiber reflective mirrors and interleaves together two fiber Michelson interferometers that share the common-interferometric-optical path, is presented. One of the fiber interferometers is used to stabilise the system by the use of an electronic feedback loop to compensate the influences resulting from the environmental disturbances, while the other one is used to perform the measurement task. The influences resulting from the environmental disturbances have been eliminated by the compensating action of the electronic feedback loop, this makes the system suitable for on-line precision measurement. By means of the homodyne phase-tracking technique, the linearity of the measurement results of displacement measurements has been very high.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis describes the design and development of an autonomous micro-drilling system capable of accurately controlling the penetration of complaint tissues and its application to the drilling of the cochleostomy; a key stage in the cochlea implant procedure. The drilling of the cochleostomy is a precision micro-surgical task in which the control of the burr penetration through the outer bone tissue of the cochlea is vital to prevent damage to the structures within and requires a high degree of skill to perform successfully. The micro-drilling system demonstrates that the penetration of the cochlea can be achieved consistently and accurately. Breakthrough can be detected and controlled to within 20µm of the distal surface and the hole completed without perforation of the underlying endosteal membrane, leaving the membranous cochlea intact. This device is the first autonomous surgical tool successfully deployed in the operating theatre. The system is unique due to the way in which it uses real-time data from the cutting tool to derive the state of the tool-tissue interaction. Being a smart tool it uses this state information to actively control the way in which the drilling process progresses. This sensor guided strategy enables the tool to self-reference to the deforming tissue and navigate without the need for pre-operative scan data. It is this capability that enables the system to operate in circumstances where the tissue properties and boundary conditions are unknown, without the need to restrain the patient.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We propose a self-reference multiplexed fibre interferometer (MFI) by using a tunable laser and fibre Bragg grating (FBG). The optical measurement system multiplexes two Michelson fibre interferometers with shared optical path in the main part of optical system. One fibre optic interferometer is used as a reference interferometer to monitor and control the high accuracy of the measurement system under environmental perturbations. The other is used as a measurement interferometer to obtain information from the target. An active phase tracking homodyne (APTH) technique is applied for signal processing to achieve high resolution. MFI can be utilised for high precision absolute displacement measurement with different combination of wavelengths from the tuneable laser. By means of Wavelength-Division-Multiplexing (WDM) technique, MFI is also capable of realising on-line surface measurement, in which traditional stylus scanning is replaced by spatial light-wave scanning so as to greatly improve the measurement speed and robustness.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We propose a self-reference multiplexed fibre interferometer (MFI) by using a tunable laser and fibre Bragg grating (FBG). The optical measurement system multiplexes two Michelson fibre interferometers with shared optical path in the main part of optical system. One fibre optic interferometer is used as a reference interferometer to monitor and control the high accuracy of the measurement system under environmental perturbations. The other is used as a measurement interferometer to obtain information from the target. An active phase tracking homodyne (APTH) technique is applied for signal processing to achieve high resolution. MFI can be utilised for high precision absolute displacement measurement with different combination of wavelengths from the tuneable laser. By means of Wavelength-Division-Multiplexing (WDM) technique, MFI is also capable of realising on-line surface measurement, in which traditional stylus scanning is replaced by spatial light-wave scanning so as to greatly improve the measurement speed and robustness. © 2004 Optical Society of America.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Report of the Robens Committee (1972), the Health and Safety at Work Act (1974) and the Safety Representatives and Safety Committees Regulations (1977) provide the framework within which this study of certain aspects of health and safety is carried out. The philosophy of self-regulation is considered and its development is set within an historical and an industrial relations perspective. The research uses a case study approach to examine the effectiveness of self-regulation in health and safety in a public sector organisation. Within this approach, methodological triangulation employs the techniques of interviews, questionnaires, observation and documentary analysis. The work is based in four departments of a Scottish Local Authority and particular attention is given to three of the main 'agents' of self-regulation - safety representatives, supervisors and safety committees and their interactions, strategies and effectiveness. A behavioural approach is taken in considering the attitudes, values, motives and interactions of safety representatives and management. Major internal and external factors, which interact and which influence the effectiveness of joint self-regulation of health and safety, are identified. It is emphasised that an organisation cannot be studied without consideration of the context within which it operates both locally and in the wider environment. One of these factors, organisational structure, is described as bureaucratic and the model of a Representative Bureaucracy described by Gouldner (1954) is compared with findings from the present study. An attempt is made to ascertain how closely the Local Authority fits Gouldner's model. This research contributes both to knowledge and to theory in the subject area by providing an in-depth study of self-regulation in a public sector organisation, which when compared with such studies as those of Beaumont (1980, 1981, 1982) highlights some of the differences between the public and private sectors. Both empirical data and hypothetical models are used to provide description and explanation of the operation of the health and safety system in the Local Authority. As data were collected during a dynamic period in economic, political and social terms, the research discusses some of the effects of the current economic recession upon safety organisation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Self-awareness and self-expression are promising architectural concepts for embedded systems to be equipped with to match them with dedicated application scenarios and constraints in the avionic and space-flight industry. Typically, these systems operate in largely undefined environments and are not reachable after deployment for a long time or even never ever again. This paper introduces a reference architecture as well as a novel modelling and simulation environment for self-aware and self-expressive systems with transaction level modelling, simulation and detailed modelling capabilities for hardware aspects, precise process chronology execution as well as fine timing resolutions. Furthermore, industrial relevant system sizes with several self-aware and self-expressive nodes can be handled by the modelling and simulation environment.