19 resultados para scattering parameters measurement
em Aston University Research Archive
Resumo:
Two energy grass species, switch grass, a North American tuft grass, and reed canary grass, a European native, are likely to be important sources of biomass in Western Europe for the production of biorenewable energy. Matching chemical composition to conversion efficiency is a primary goal for improvement programmes and for determining the quality of biomass feed-stocks prior to use and there is a need for methods which allow cost effective characterisation of chemical composition at high rates of sample through-put. In this paper we demonstrate that nitrogen content and alkali index, parameters greatly influencing thermal conversion efficiency, can be accurately predicted in dried samples of these species grown under a range of agronomic conditions by partial least square regression of Fourier transform infrared spectra (R2 values for plots of predicted vs. measured values of 0.938 and 0.937, respectively). We also discuss the prediction of carbon and ash content in these samples and the application of infrared based predictive methods for the breeding improvement of energy grasses.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
A new numerical model which incorporates Brillouin shift frequency variations arising from fibre inhomogeneities has been developed for stimulated Brillouin scattering in optical fibres. This enables simulations of backscattered and transmitted power as functions of input power based only on known physical and material parameters as well as the polarisation factor and the measured Brillouin gain linewidth for the fibre. Agreement between modelled and experimental power characteristics for a CW input is excellent.
Resumo:
A new surface analysis technique has been developed which has a number of benefits compared to conventional Low Energy Ion Scattering Spectrometry (LEISS). A major potential advantage arising from the absence of charge exchange complications is the possibility of quantification. The instrumentation that has been developed also offers the possibility of unique studies concerning the interaction between low energy ions and atoms and solid surfaces. From these studies it may also be possible, in principle, to generate sensitivity factors to quantify LEISS data. The instrumentation, which is referred to as a Time-of-Flight Fast Atom Scattering Spectrometer has been developed to investigate these conjecture in practice. The development, involved a number of modifications to an existing instrument, and allowed samples to be bombarded with a monoenergetic pulsed beam of either atoms or ions, and provided the capability to analyse the spectra of scattered atoms and ions separately. Further to this a system was designed and constructed to allow incident, exit and azimuthal angles of the particle beam to be varied independently. The key development was that of a pulsed, and mass filtered atom source; which was developed by a cyclic process of design, modelling and experimentation. Although it was possible to demonstrate the unique capabilities of the instrument, problems relating to surface contamination prevented the measurement of the neutralisation probabilities. However, these problems appear to be technical rather than scientific in nature, and could be readily resolved given the appropriate resources. Experimental spectra obtained from a number of samples demonstrate some fundamental differences between the scattered ion and neutral spectra. For practical non-ordered surfaces the ToF spectra are more complex than their LEISS counterparts. This is particularly true for helium scattering where it appears, in the absence of detailed computer simulation, that quantitative analysis is limited to ordered surfaces. Despite this limitation the ToFFASS instrument opens the way for quantitative analysis of the 'true' surface region to a wider range of surface materials.
Resumo:
Boyd's SBS model which includes distributed thermal acoustic noise (DTAN) has been enhanced to enable the Stokes-spontaneous density depletion noise (SSDDN) component of the transmitted optical field to be simulated, probably for the first time, as well as the full transmitted field. SSDDN would not be generated from previous SBS models in which a Stokes seed replaces DTAN. SSDDN becomes the dominant form of transmitted SBS noise as model fibre length (MFL) is increased but its optical power spectrum remains independent of MFL. Simulations of the full transmitted field and SSDDN for different MFLs allow prediction of the optical power spectrum, or system performance parameters which depend on this, for typical communication link lengths which are too long for direct simulation. The SBS model has also been innovatively improved by allowing the Brillouin Shift Frequency (BS) to vary over the model fibre length, for the nonuniform fibre model (NFM) mode, or to remain constant, for the uniform fibre model (UFM) mode. The assumption of a Gaussian probability density function (pdf) for the BSF in the NFM has been confirmed by means of an analysis of reported Brillouin amplified power spectral measurements for the simple case of a nominally step-index single-mode pure silica core fibre. The BSF pdf could be modified to match the Brillouin gain spectra of other fibre types if required. For both models, simulated backscattered and output powers as functions of input power agree well with those from a reported experiment for fitting Brillouin gain coefficients close to theoretical. The NFM and UFM Brillouin gain spectra are then very similar from half to full maximum but diverge at lower values. Consequently, NFM and UFM transmitted SBS noise powers inferred for long MFLs differ by 1-2 dB over the input power range of 0.15 dBm. This difference could be significant for AM-VSB CATV links at some channel frequencies. The modelled characteristic of Carrier-to-Noise Ratio (CNR) as a function of input power for a single intensity modulated subcarrier is in good agreement with the characteristic reported for an experiment when either the UFM or NFM is used. The difference between the two modelled characteristics would have been more noticeable for a higher fibre length or a lower subcarrier frequency.
Resumo:
A mathematical model has been developed for predicting the spectral distribution of solar radiation incident on a horizontal surface. The solar spectrum in the wavelength range 0.29 to 4.0 micrometers has been divided in 144 intervals. Two variables in the model are the atmospheric water vapour content and atmospheric turbidity. After allowing for absorption and scattering in the atmosphere, the spectral intensity of direct and diffuse components of radiation are computed. When the predicted radiation levels are compared with the measured values for the total radiation and the values with glass filters RG715, RG630 and OG530, a close agreement (± 5%) has been achieved under clear sky conditions. A solar radiation measuring facility, close to the centre of Birmingham, has been set up utilising a microcomputer based data logging system. A suite of computer programs in the BASIC programming language has been developed and extensively tested for solar radiation data, logging, analysis and plotting. Two commonly used instruments, the Eppley PSP pyranometer and the Kipp and Zonen CM5 pyranometer, have been compared under different experimental conditions. Three models for computing the inclined plane irradiation, using total and diffuse radiation on a horizontal surface, have been tested for Birmingham. The anisotropic-alI-sky model, proposed by Klucher, provides a good agreement between the measured and the predicted radiation levels. Measurements of solar spectral distribution, using glass filters, are also reported for a number of inclines facing South.
Resumo:
We report on a novel experimental setup for distributed measurement of temperature, based on spontaneous Brillouin scattering in optical fiber. We have developed a mode-locked Brillouin fiber ring laser in order to generate the dual frequency source required for a heterodyne detection of the backscattered signal. This relatively simple system enables temperature measurements over 20 km with a spatial resolution of 7 m.
Resumo:
Distributed Brillouin sensing of strain and temperature works by making spatially resolved measurements of the position of the measurand-dependent extremum of the resonance curve associated with the scattering process in the weakly nonlinear regime. Typically, measurements of backscattered Stokes intensity (the dependent variable) are made at a number of predetermined fixed frequencies covering the design measurand range of the apparatus and combined to yield an estimate of the position of the extremum. The measurand can then be found because its relationship to the position of the extremum is assumed known. We present analytical expressions relating the relative error in the extremum position to experimental errors in the dependent variable. This is done for two cases: (i) a simple non-parametric estimate of the mean based on moments and (ii) the case in which a least squares technique is used to fit a Lorentzian to the data. The question of statistical bias in the estimates is discussed and in the second case we go further and present for the first time a general method by which the probability density function (PDF) of errors in the fitted parameters can be obtained in closed form in terms of the PDFs of the errors in the noisy data.
Resumo:
An initial aim of this project was to evaluate the conventional techniques used in the analysis of newly prepared environmentally friendly water-borne automotive coatings and compare them with solvent-borne coatings having comparable formulations. The investigation was carried out on microtuned layers as well as on complete automotive multi-layer paint systems. Methods used included the very traditional methods of gloss and hardness and the commonly used photo-oxidation index (from FTIR spectral analysis). All methods enabled the durability to weathering of the automotive coatings to be initially investigated. However, a primary aim of this work was to develop methods for analysing the early stages of chemical and property changes in both the solvent-borne and water-borne coating systems that take place during outdoor natural weathering exposures and under accelerated artificial exposures. This was achieved by using dynamic mechanical analysis (DMA), in both tension mode on the microtomed films (on all depths of the coating systems from the uppermost clear-coat right down to the electron-coat) and bending mode of the full (unmicrotomed) systems, as well as MALDI-Tof analysis on the movement of the stabilisers in the full systems. Changes in glass transition temperature and relative cross-link density were determined after weathering and these were related to changes in the chemistries of the binder systems of the coatings after weathering. Concentration profiles of the UV-stabilisers (UVA and HALS) in the coating systems were analysed as a consequence of migration in the coating systems in separate microtomed layers of the paint samples (depth profiling) after weathering and diffusion co-efficient and solubility parameters were determined for the UV stabilisers in the coating systems. The methods developed were used to determine the various physical and chemical changes that take place during weathering of the different (water-borne and solvent-borne) systems (photoxidation). The solvent-borne formulations showed less changes after weathering (both natural and accelerated) than the corresponding water-borne formulations due to the lower level of cross-links in the binders of the water-borne systems. The silver systems examined were more durable than the blue systems due to the reflecting power of the aluminium and the lower temperature of the silver coatings.
Resumo:
Background: Heterochromatic flicker photometry (HFP) is a psychophysical technique used to measure macular pigment optical density (MPOD). We used the MPS 9000 (MPS) HFP device. Our aim was to determine if the repeatability of the MPS could be improved to make it more suitable for monitoring MPOD over time. Methods: Intra-session repeatability was assessed in 25 participants (aged 20-50 years). The resulting data was explored in detail, e.g., by examining the effect of removal and adjustment of data with less than optimal quality parameters. A protocol was developed for improved overall reliability, which was then tested in terms of inter-session repeatability in a separate group of 27 participants (aged 19-52 years). Results: Removal and adjustment of data reduced the intra-session coefficient of repeatability (CR) by 0.04, on average, and the mean individual standard deviation by 0.004. Raw data observation offered further insight into ways of improving repeatability. The proposed protocol resulted in an inter-session CR of 0.08. Conclusions: Removal and adjustment of less than optimal data improved repeatability, and is therefore recommended. To further improve repeatability, in brief we propose that each patient perform each part of the test twice, and a third time where necessary (described in detail by the protocol). Doing so will make the MPS more useful in research and clinical settings. © 2012 Springer-Verlag.
Resumo:
The rationale for carrying out this research was to address the clear lack of knowledge surrounding the measurement of public hospital performance in Ireland. The objectives of this research were to develop a comprehensive model for measuring hospital performance and using this model to measure the performance of public acute hospitals in Ireland in 2007. Having assessed the advantages and disadvantages of various measurement models the Data Envelopment Analysis (DEA) model was chosen for this research. DEA was initiated by Charnes, Cooper and Rhodes in 1978 and further developed by Fare et al. (1983) and Banker et al. (1984). The method used to choose relevant inputs and outputs to be included in the model followed that adopted by Casu et al. (2005) which included the use of focus groups. The main conclusions of the research are threefold. Firstly, it is clear that each stakeholder group has differing opinions on what constitutes good performance. It is therefore imperative that any performance measurement model would be designed within parameters that are clearly understood by any intended audience. Secondly, there is a lack of publicly available qualitative information in Ireland that inhibits detailed analysis of hospital performance. Thirdly, based on available qualitative and quantitative data the results indicated a high level of efficiency among the public acute hospitals in Ireland in their staffing and non pay costs, averaging 98.5%. As DEA scores are sensitive to the number of input and output variables as well as the size of the sample it should be borne in mind that a high level of efficiency could be as a result of using DEA with too many variables compared to the number of hospitals. No hospital was deemed to be scale efficient in any of the models even though the average scale efficiency for all of the hospitals was relatively high at 90.3%. Arising from this research the main recommendations would be that information on medical outcomes, survival rates and patient satisfaction should be made publicly available in Ireland; that despite a high average efficiency level that many individual hospitals need to focus on improving their technical and scale efficiencies, and that performance measurement models should be developed that would include more qualitative data.
Resumo:
Distributed Brillouin sensing of strain and temperature works by making spatially resolved measurements of the position of the measurand-dependent extremum of the resonance curve associated with the scattering process in the weakly nonlinear regime. Typically, measurements of backscattered Stokes intensity (the dependent variable) are made at a number of predetermined fixed frequencies covering the design measurand range of the apparatus and combined to yield an estimate of the position of the extremum. The measurand can then be found because its relationship to the position of the extremum is assumed known. We present analytical expressions relating the relative error in the extremum position to experimental errors in the dependent variable. This is done for two cases: (i) a simple non-parametric estimate of the mean based on moments and (ii) the case in which a least squares technique is used to fit a Lorentzian to the data. The question of statistical bias in the estimates is discussed and in the second case we go further and present for the first time a general method by which the probability density function (PDF) of errors in the fitted parameters can be obtained in closed form in terms of the PDFs of the errors in the noisy data.
Resumo:
We report on a novel experimental setup for distributed measurement of temperature, based on spontaneous Brillouin scattering in optical fiber. We have developed a mode-locked Brillouin fiber ring laser in order to generate the dual frequency source required for a heterodyne detection of the backscattered signal. This relatively simple system enables temperature measurements over 20 km with a spatial resolution of 7 m.
Resumo:
A compact and low cost fiber sensor based on microfiber with Fresnel reflection is proposed and demonstrated for simultaneous measurement of refractive index (RI) and temperature with high sensitivities. © OSA 2015.