91 resultados para sagnac interferometer

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dibit recovery of a DQPSK signal will be demonstrated using a single Mach Zehnder Interferometer, containing a 1-bit delay, and a single balanced receiver. The electrical output levels of the balanced receiver are dependent upon the relative phase delay between the arms of the Mach Zehnder Interferometer. This paper will investigate this characteristic when the input signal is DQPSK modulated. It will also be shown that with a certain amount of phase shift the DQPSK signal can be converted into four different equally spaced electrical signal levels. With each decoded level representing one of the four possible dibits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this research the recovery of a DQPSK signal will be demonstrated using a single Mach-Zehnder Interferometer (MZI). By changing the phase delay in one of the arms it will be shown that different delays will produce different output levels. It will also be shown that with a certain level of phase shift the DQPSK signal can be converted into four different equally spaced optical power levels. With each decoded level representing one of the four possible bit permutations. By using this additional phase shift in one of the arms the number of MZIs required for decoding can be reduced from two to one.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A low cost interrogation scheme is demonstrated for a refractometer based on an in-line fiber long period grating (LPG) Mach–Zehnder interferometer. Using this interrogation scheme the minimum detectable change in refractive index of ?n ~ 1.8×10-6 is obtained, which is the highest resolution achieved using a fiber LPG device, and is comparable to precision techniques used in the industry including high performance liquid chromatography and ultraviolet spectroscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of high birefringence fibre forming a differential path interferometer as an interrogation unit for heterodyne fibre optic sensing applications is described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A self-reference fiber Michelson interferometer measurement system, which employs fiber Bragg gratings (FBGs) as in-fiber reflective mirrors and interleaves together two fiber Michelson interferometers that share the common-interferometric-optical path, is presented. One of the fiber interferometers is used to stabilise the system by the use of an electronic feedback loop to compensate the influences resulting from the environmental disturbances, while the other one is used to perform the measurement task. The influences resulting from the environmental disturbances have been eliminated by the compensating action of the electronic feedback loop, this makes the system suitable for on-line precision measurement. By means of the homodyne phase-tracking technique, the linearity of the measurement results of displacement measurements has been very high.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a novel and simple sensor interrogation scheme for fiber Bragg grating (FBG) based sensing systems. In this scheme, a chirped FBG based Sagnac loop is used as a wavelength-dependent receiver, and a stable and linear readout response is realised. It is a signijkant advantage of this scheme that the sensitivity and the measurement wavelength range can be easily adjhsted by controlling the chirp of the FBG or using an optical delay line in the Sagnac loop.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel high-frequency fiber Bragg grating (FBG) sensing interrogation system by using fiber Sagnac-loop-based microwave photonic filtering is proposed and experimentally demonstrated. By adopting the microwave photonic filtering, the wavelength shift of sensing FBG can be converted into amplitude variation of the modulated electronic radio-frequency (RF) signal. In the experiment, the strain applied onto the sensing FBG has been demodulated by measuring the intensity of the recovered RF signal, and by modulating the RF signal with different frequencies, different interrogation sensitivities can be achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical first order calculation of the impact of Gaussian white noise on a novel single Mach-Zehnder Interferometer demodulation scheme for DQPSK reveals a constant Q factor ratio to the conventional scheme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of high birefringence fiber interrogating interferometer for optical sensing applications was discussed. The method is of low cost and permits simple adjustment of the optical path difference and has much lower sensitivity to environmental perturbation. The polarization-maintaining (PM) fiber interferometer adopted a heterodyne approach using interferometric wavelength shift detection. The study showed that the inclusion of power amplifier driving a multi-element piezoelectric stack will enable the bandwidth to be pushed up into the kHz regime.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optical liquid-level sensor (LLS) based on a long-period fiber grating (LPG) interferometer is proposed and experimentally demonstrated. Two identical 3-dB LPGs are fabricated to form an in-fiber Mach-Zehnder interferometer, and the fiber portion between two LPGs is exposed to the liquid as the sensing element. The sensitivity and measurement range of the sensors employing different orders of cladding modes are investigated both theoretically and experimentally. The experimental results show good linearity and large measurement range. One of the significant advantages of such a sensing structure is that the measurement level is not limited to the length of the LPG itself. Also, the measurement range and sensitivity of the proposed LLS can be readily tailored for a particular applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a self-reference multiplexed fibre interferometer (MFI) by using a tunable laser and fibre Bragg grating (FBG). The optical measurement system multiplexes two Michelson fibre interferometers with shared optical path in the main part of optical system. One fibre optic interferometer is used as a reference interferometer to monitor and control the high accuracy of the measurement system under environmental perturbations. The other is used as a measurement interferometer to obtain information from the target. An active phase tracking homodyne (APTH) technique is applied for signal processing to achieve high resolution. MFI can be utilised for high precision absolute displacement measurement with different combination of wavelengths from the tuneable laser. By means of Wavelength-Division-Multiplexing (WDM) technique, MFI is also capable of realising on-line surface measurement, in which traditional stylus scanning is replaced by spatial light-wave scanning so as to greatly improve the measurement speed and robustness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optical liquid-level sensor (LLS) based on a long-period fiber grating (LPG) interferometer is proposed and experimentally demonstrated. Two identical 3-dB LPGs are fabricated to form an in-fiber Mach-Zehnder interferometer, and the fiber portion between two LPGs is exposed to the liquid as the sensing element. The sensitivity and measurement range of the sensors employing different orders of cladding modes are investigated both theoretically and experimentally. The experimental results show good linearity and large measurement range. One of the significant advantages of such a sensing structure is that the measurement level is not limited to the length of the LPG itself. Also, the measurement range and sensitivity of the proposed LLS can be readily tailored for a particular applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a novel and simple sensor interrogation scheme for fiber Bragg grating (FBG) based sensing systems. In this scheme, a chirped FBG based Sagnac loop is used as a wavelength-dependent receiver, and a stable and linear readout response is realised. It is a signijkant advantage of this scheme that the sensitivity and the measurement wavelength range can be easily adjhsted by controlling the chirp of the FBG or using an optical delay line in the Sagnac loop.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The turning point of the refractive index (RI) sensitivity based on the multimode microfiber (MMMF) in-line Mach–Zehnder interferometer (MZI) is observed. By tracking the resonant wavelength shift of the MZI generated between the HE11 and HE12 modes in the MMMF, the surrounding RI (SRI) could be detected. Theoretical analysis demonstrates that the RI sensitivity will reach ±∞ on either side of the turning point due to the group effective RI difference (퐺) approaching zero. Significantly, the positive sensitivity exists in a very wide fiber diameter range, while the negative sensitivity can be achieved in a narrow diameter range of only 0.3 μm. Meanwhile, the experimental sensitivities and variation trend at different diameters exhibit high consistency with the theoretical results. High RI sensitivity of 10777.8 nm/RIU (RI unit) at the fiber diameter of 4.6 μm and the RI around 1.3334 is realized. The discovery of the sensitivity turning points has great significance on trace detection due to the possibility of ultrahigh RI sensitivity.