9 resultados para safety monitoring

em Aston University Research Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Deep hole drilling is one of the most complicated metal cutting processes and one of the most difficult to perform on CNC machine-tools or machining centres under conditions of limited manpower or unmanned operation. This research work investigates aspects of the deep hole drilling process with small diameter twist drills and presents a prototype system for real time process monitoring and adaptive control; two main research objectives are fulfilled in particular : First objective is the experimental investigation of the mechanics of the deep hole drilling process, using twist drills without internal coolant supply, in the range of diarneters Ø 2.4 to Ø4.5 mm and working length up to 40 diameters. The definition of the problems associated with the low strength of these tools and the study of mechanisms of catastrophic failure which manifest themselves well before and along with the classic mechanism of tool wear. The relationships between drilling thrust and torque with the depth of penetration and the various machining conditions are also investigated and the experimental evidence suggests that the process is inherently unstable at depths beyond a few diameters. Second objective is the design and implementation of a system for intelligent CNC deep hole drilling, the main task of which is to ensure integrity of the process and the safety of the tool and the workpiece. This task is achieved by means of interfacing the CNC system of the machine tool to an external computer which performs the following functions: On-line monitoring of the drilling thrust and torque, adaptive control of feed rate, spindle speed and tool penetration (Z-axis), indirect monitoring of tool wear by pattern recognition of variations of the drilling thrust with cumulative cutting time and drilled depth, operation as a data base for tools and workpieces and finally issuing of alarms and diagnostic messages.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The activities and function of the West Midlands Adverse Drug Reaction Study Group are described. The impact of the Group on the reporting of adverse drug reactions to the CSM by the yellow card system has been evaluated in several ways including a comparison with the Trent Region. The role of the pharmacist in the Group is highlighted. A nationwide survey of the hospital pharmacist's involvement in adverse drug reaction reporting and monitoring is described, the results are reported and discussed. The available sources of information on adverse drug reactions, both primary and secondary, are critically reviewed. A checklist of necessary details for case reports is developed and examples of problems in the literature are given. The contribution of the drug information pharmacist in answering enquiries and encouraging reporting is examined. A role for the ward pharmacist in identifying, reporting, documenting and following up adverse drug reactions is proposed. Studies conducted to support this role are described and the results discussed. The ward pharmacist's role in preventing adverse drug reactions is also outlined. The reporting of adverse drug reactions in Australia is contrasted with the U.K. and particular attention is drawn to the pharmacist's contribution in the former. The problems in evaluating drug safety are discussed and examples are given where serious reactions have only been recognised after many patients have been exposed. To remedy this situation a case is made for enhancing the CSM yellow card scheme by further devolution of reporting, increasing the involvement of pharmacists and improving arrangements at the CSM. It is proposed that pharmacists should undertake the responsibility for reporting reactions to the CSM in some instances.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the case of surgical scalpels, blade retraction and disposability have been incorporated into a number of commercial designs to address sharps injury and infection transmission issues. Despite these new designs, the traditional metal reusable scalpel is still extensively used and this paper attempts to determine whether the introduction of safety features has compromised the ergonomics and so potentially the take-up of the newer designs. Examples of scalpels have been analysed to determine the ergonomic impact of these design changes. Trials and questionnaires were carried out using both clinical and non-clinical user groups, with the trials making use of assessment of incision quality, cutting force, electromyography and video monitoring. The results showed that ergonomic performance was altered by the design changes and that while these could be for the worse, the introduction of safety features could act as a catalyst to encourage re-evaluation of the ergonomic demands of a highly traditional product.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To independently evaluate the impact of the second phase of the Health Foundation's Safer Patients Initiative (SPI2) on a range of patient safety measures. Design: A controlled before and after design. Five substudies: survey of staff attitudes; review of case notes from high risk (respiratory) patients in medical wards; review of case notes from surgical patients; indirect evaluation of hand hygiene by measuring hospital use of handwashing materials; measurement of outcomes (adverse events, mortality among high risk patients admitted to medical wards, patients' satisfaction, mortality in intensive care, rates of hospital acquired infection). Setting: NHS hospitals in England. Participants: Nine hospitals participating in SPI2 and nine matched control hospitals. Intervention The SPI2 intervention was similar to the SPI1, with somewhat modified goals, a slightly longer intervention period, and a smaller budget per hospital. Results: One of the scores (organisational climate) showed a significant (P=0.009) difference in rate of change over time, which favoured the control hospitals, though the difference was only 0.07 points on a five point scale. Results of the explicit case note reviews of high risk medical patients showed that certain practices improved over time in both control and SPI2 hospitals (and none deteriorated), but there were no significant differences between control and SPI2 hospitals. Monitoring of vital signs improved across control and SPI2 sites. This temporal effect was significant for monitoring the respiratory rate at both the six hour (adjusted odds ratio 2.1, 99% confidence interval 1.0 to 4.3; P=0.010) and 12 hour (2.4, 1.1 to 5.0; P=0.002) periods after admission. There was no significant effect of SPI for any of the measures of vital signs. Use of a recommended system for scoring the severity of pneumonia improved from 1.9% (1/52) to 21.4% (12/56) of control and from 2.0% (1/50) to 41.7% (25/60) of SPI2 patients. This temporal change was significant (7.3, 1.4 to 37.7; P=0.002), but the difference in difference was not significant (2.1, 0.4 to 11.1; P=0.236). There were no notable or significant changes in the pattern of prescribing errors, either over time or between control and SPI2 hospitals. Two items of medical history taking (exercise tolerance and occupation) showed significant improvement over time, across both control and SPI2 hospitals, but no additional SPI2 effect. The holistic review showed no significant changes in error rates either over time or between control and SPI2 hospitals. The explicit case note review of perioperative care showed that adherence rates for two of the four perioperative standards targeted by SPI2 were already good at baseline, exceeding 94% for antibiotic prophylaxis and 98% for deep vein thrombosis prophylaxis. Intraoperative monitoring of temperature improved over time in both groups, but this was not significant (1.8, 0.4 to 7.6; P=0.279), and there were no additional effects of SPI2. A dramatic rise in consumption of soap and alcohol hand rub was similar in control and SPI2 hospitals (P=0.760 and P=0.889, respectively), as was the corresponding decrease in rates of Clostridium difficile and meticillin resistant Staphylococcus aureus infection (P=0.652 and P=0.693, respectively). Mortality rates of medical patients included in the case note reviews in control hospitals increased from 17.3% (42/243) to 21.4% (24/112), while in SPI2 hospitals they fell from 10.3% (24/233) to 6.1% (7/114) (P=0.043). Fewer than 8% of deaths were classed as avoidable; changes in proportions could not explain the divergence of overall death rates between control and SPI2 hospitals. There was no significant difference in the rate of change in mortality in intensive care. Patients' satisfaction improved in both control and SPI2 hospitals on all dimensions, but again there were no significant changes between the two groups of hospitals. Conclusions: Many aspects of care are already good or improving across the NHS in England, suggesting considerable improvements in quality across the board. These improvements are probably due to contemporaneous policy activities relating to patient safety, including those with features similar to the SPI, and the emergence of professional consensus on some clinical processes. This phenomenon might have attenuated the incremental effect of the SPI, making it difficult to detect. Alternatively, the full impact of the SPI might be observable only in the longer term. The conclusion of this study could have been different if concurrent controls had not been used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To conduct an independent evaluation of the first phase of the Health Foundation's Safer Patients Initiative (SPI), and to identify the net additional effect of SPI and any differences in changes in participating and non-participating NHS hospitals. Design: Mixed method evaluation involving five substudies, before and after design. Setting: NHS hospitals in United Kingdom. Participants: Four hospitals (one in each country in the UK) participating in the first phase of the SPI (SPI1); 18 control hospitals. Intervention: The SPI1 was a compound (multicomponent) organisational intervention delivered over 18 months that focused on improving the reliability of specific frontline care processes in designated clinical specialties and promoting organisational and cultural change. Results: Senior staff members were knowledgeable and enthusiastic about SPI1. There was a small (0.08 points on a 5 point scale) but significant (P<0.01) effect in favour of the SPI1 hospitals in one of 11 dimensions of the staff questionnaire (organisational climate). Qualitative evidence showed only modest penetration of SPI1 at medical ward level. Although SPI1 was designed to engage staff from the bottom up, it did not usually feel like this to those working on the wards, and questions about legitimacy of some aspects of SPI1 were raised. Of the five components to identify patients at risk of deterioration - monitoring of vital signs (14 items); routine tests (three items); evidence based standards specific to certain diseases (three items); prescribing errors (multiple items from the British National Formulary); and medical history taking (11 items) - there was little net difference between control and SPI1 hospitals, except in relation to quality of monitoring of acute medical patients, which improved on average over time across all hospitals. Recording of respiratory rate increased to a greater degree in SPI1 than in control hospitals; in the second six hours after admission recording increased from 40% (93) to 69% (165) in control hospitals and from 37% (141) to 78% (296) in SPI1 hospitals (odds ratio for "difference in difference" 2.1, 99% confidence interval 1.0 to 4.3; P=0.008). Use of a formal scoring system for patients with pneumonia also increased over time (from 2% (102) to 23% (111) in control hospitals and from 2% (170) to 9% (189) in SPI1 hospitals), which favoured controls and was not significant (0.3, 0.02 to 3.4; P=0.173). There were no improvements in the proportion of prescription errors and no effects that could be attributed to SPI1 in non-targeted generic areas (such as enhanced safety culture). On some measures, the lack of effect could be because compliance was already high at baseline (such as use of steroids in over 85% of cases where indicated), but even when there was more room for improvement (such as in quality of medical history taking), there was no significant additional net effect of SPI1. There were no changes over time or between control and SPI1 hospitals in errors or rates of adverse events in patients in medical wards. Mortality increased from 11% (27) to 16% (39) among controls and decreased from17%(63) to13%(49) among SPI1 hospitals, but the risk adjusted difference was not significant (0.5, 0.2 to 1.4; P=0.085). Poor care was a contributing factor in four of the 178 deaths identified by review of case notes. The survey of patients showed no significant differences apart from an increase in perception of cleanliness in favour of SPI1 hospitals. Conclusions The introduction of SPI1 was associated with improvements in one of the types of clinical process studied (monitoring of vital signs) and one measure of staff perceptions of organisational climate. There was no additional effect of SPI1 on other targeted issues nor on other measures of generic organisational strengthening.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Maintaining the structural health of prestressed concrete nuclear containments is a key element in ensuring nuclear reactors are capable of meeting their safety requirements. This paper discusses the attachment, fabrication and characterisation of optical fibre strain sensors suitable for the prestress monitoring of irradiated steel prestressing tendons. The all-metal fabrication and welding process allowed the instrumented strand to simultaneously monitor and apply stresses up to 1300 MPa (80% of steel's ultimate tensile strength). There were no adverse effects to the strand's mechanical properties or integrity. After sensor relaxation through cyclic stress treatment, strain transfer between the optical fibre sensors and the strand remained at 69%. The fibre strain sensors could also withstand the non-axial forces induced as the strand was deflected around a 4.5 m bend radius. Further development of this technology has the potential to augment current prestress monitoring practices, allowing distributed measurements of short- and long-term prestress losses in nuclear prestressed-concrete vessels. © 2014 Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Liquid-level sensing technologies have attracted great prominence, because such measurements are essential to industrial applications, such as fuel storage, flood warning and in the biochemical industry. Traditional liquid level sensors are based on electromechanical techniques; however they suffer from intrinsic safety concerns in explosive environments. In recent years, given that optical fiber sensors have lots of well-established advantages such as high accuracy, costeffectiveness, compact size, and ease of multiplexing, several optical fiber liquid level sensors have been investigated which are based on different operating principles such as side-polishing the cladding and a portion of core, using a spiral side-emitting optical fiber or using silica fiber gratings. The present work proposes a novel and highly sensitive liquid level sensor making use of polymer optical fiber Bragg gratings (POFBGs). The key elements of the system are a set of POFBGs embedded in silicone rubber diaphragms. This is a new development building on the idea of determining liquid level by measuring the pressure at the bottom of a liquid container, however it has a number of critical advantages. The system features several FBG-based pressure sensors as described above placed at different depths. Any sensor above the surface of the liquid will read the same ambient pressure. Sensors below the surface of the liquid will read pressures that increase linearly with depth. The position of the liquid surface can therefore be approximately identified as lying between the first sensor to read an above-ambient pressure and the next higher sensor. This level of precision would not in general be sufficient for most liquid level monitoring applications; however a much more precise determination of liquid level can be made by linear regression to the pressure readings from the sub-surface sensors. There are numerous advantages to this multi-sensor approach. First, the use of linear regression using multiple sensors is inherently more accurate than using a single pressure reading to estimate depth. Second, common mode temperature induced wavelength shifts in the individual sensors are automatically compensated. Thirdly, temperature induced changes in the sensor pressure sensitivity are also compensated. Fourthly, the approach provides the possibility to detect and compensate for malfunctioning sensors. Finally, the system is immune to changes in the density of the monitored fluid and even to changes in the effective force of gravity, as might be obtained in an aerospace application. The performance of an individual sensor was characterized and displays a sensitivity (54 pm/cm), enhanced by more than a factor of 2 when compared to a sensor head configuration based on a silica FBG published in the literature, resulting from the much lower elastic modulus of POF. Furthermore, the temperature/humidity behavior and measurement resolution were also studied in detail. The proposed configuration also displays a highly linear response, high resolution and good repeatability. The results suggest the new configuration can be a useful tool in many different applications, such as aircraft fuel monitoring, and biochemical and environmental sensing, where accuracy and stability are fundamental. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract PURPOSE: To evaluate ranibizumab 0.5 mg using bimonthly monitoring and individualized re-treatment after monthly follow-up for 6 months in patients with visual impairment due to diabetic macular edema (DME). DESIGN: A phase IIIb, 18-month, prospective, open-label, multicenter, single-arm study in the United Kingdom. PARTICIPANTS: Participants (N = 109) with visual impairment due to DME. METHODS: Participants received 3 initial monthly ranibizumab 0.5 mg injections (day 0 to month 2), followed by individualized best-corrected visual acuity (BCVA) and optical coherence tomography-guided re-treatment with monthly (months 3-5) and subsequent bimonthly follow-up (months 6-18). Laser was allowed after month 6. MAIN OUTCOME MEASURES: Mean change in BCVA from baseline to month 12 (primary end point), mean change in BCVA and central retinal thickness (CRT) from baseline to month 18, gain of ≥10 and ≥15 letters, treatment exposure, and incidence of adverse events over 18 months. RESULTS: Of 109 participants, 100 (91.7%) and 99 (90.8%) completed the 12 and 18 months of the study, respectively. The mean age was 63.7 years, the mean duration of DME was 40 months, and 77.1% of the participants had received prior laser treatment (study eye). At baseline, mean BCVA was 62.9 letters, 20% of patients had a baseline BCVA of >73 letters, and mean baseline CRT was 418.1 μm, with 32% of patients having a baseline CRT <300 μm. The mean change in BCVA from baseline to month 6 was +6.6 letters (95% confidence interval [CI], 4.9-8.3), and after institution of bimonthly treatment the mean change in BCVA at month 12 was +4.8 letters (95% CI, 2.9-6.7; P < 0.001) and +6.5 letters (95% CI, 4.2-8.8) at month 18. The proportion of participants gaining ≥10 and ≥15 letters was 24.8% and 13.8% at month 12 and 34.9% and 19.3% at month 18, respectively. Participants received a mean of 6.8 and 8.5 injections over 12 and 18 months, respectively. No new ocular or nonocular safety findings were observed during the study. CONCLUSIONS: The BCVA gain achieved in the initial 6-month treatment period was maintained with an additional 12 months of bimonthly ranibizumab PRN treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigate the role of CEO power and government monitoring on bank dividend policy for a sample of 109 European listed banks for the period 2005-2013. We employ three main proxies for CEO power: CEO ownership, CEO tenure, and unforced CEO turnover. We show that CEO power has a negative impact on dividend payout ratios and on performance, suggesting that entrenched CEOs do not have the incentive to increase payout ratios to discourage monitoring from minority shareholders. Stronger internal monitoring by board of directors, as proxied by larger ownership stakes of the board members, increases performance but decreases payout ratios. These findings are contrary to those from the entrenchment literature for non-financial firms. Government ownership and the presence of a government official on the board of directors of the bank, also reduces payout ratios, in line with the view that government is incentivized to favor the interest of bank creditors before the interest of minority shareholders. These results show that government regulators are mainly concerned about bank safety and this allows powerful CEOs to distribute low payouts at the expense of minority shareholders.