6 resultados para repeated measurement

em Aston University Research Archive


Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: To determine whether letter sequences and/or lens-presentation order should be randomized when measuring defocus curves and to assess the most appropriate criterion for calculating the subjective amplitude of accommodation (AoA) from defocus curves. SETTING: Eye Clinic, School of Life & Health Sciences, Aston University, Birmingham, United Kingdom. METHODS: Defocus curves (from +3.00 diopters [D] to -3.00 D in 0.50 D steps) for 6 possible combinations of randomized or nonrandomized letter sequences and/or lens-presentation order were measured in a random order in 20 presbyopic subjects. Subjective AoA was calculated from the defocus curves by curve fitting using various published criteria, and each was correlated to subjective push-up AoA. Objective AoA was measured for comparison of blur tolerance and pupil size. RESULTS: Randomization of lens-presentation order and/or letter sequences, or lack of, did not affect the measured defocus curves (P>.05, analysis of variance). The range of defocus that maintains highest achievable visual acuity (allowing for variability of repeated measurement) was better correlated to (r = 0.84) and agreed best with ( 0.50 D) subjective push-up AoA than any other relative or absolute acuity criterion used in previous studies. CONCLUSIONS: Nonrandomized letters and lens presentation on their own did not affect subjective AoA measured by defocus curves, although their combination should be avoided. Quantification of subjective AoA from defocus curves should be standardized to the range of defocus that maintains the best achievable visual acuity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: To assess the repeatability of Eger macular stressometer (EMS) measures of photostress recovery and determine their association with other measures of visual function. Methods: EMS photostress recovery time was measured in 90 patients with bilateral exudative age related macular degeneration (AMD), 19 with bilateral atrophic AMD and 47 with both forms of the condition (mean age 79 (SD 13) years). Measurements were made on two occasions separated by 1 year. Intrasession repeatability was assessed by repeating the measures after a 10 minute recovery period at the first visit. Distance visual acuity was measured with a logMAR chart, near visual acuity with a MNRead chart at 25 cm, contrast sensitivity with a Pelli-Robson chart, and the presence of central visual disturbance assessed with an Amsler grid. A questionnaire was used to assess self reported difficulties with glare recovery. Results: The average EMS recovery time was 11.0 (SD 8.9) seconds, decreasing by 1.6 (5.2) seconds on repeated measurement (p<0.05). EMS photostress recovery was not correlated with visual function measures or subjective difficulties with lights (p>0.05). EMS photostress recovery time did not predict those whose vision decreased over the following year compared with those among whom it remained stable. Conclusions: The EMS test is not a useful tool in determining the severity or progression of AMD.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The aim was to investigate the effect on the measured amplitude of accommodation and repeatability of using the minus lens technique with the target at distance or near. Methods: Forty-three students (average age: 21.17 ± 1.50 years, 35 female) had their amplitude of accommodation measured with minus lenses on top of their distance correction in a trial frame with the target at far (6.0m) or near (0.4m). The minus lens power was gradually added with steps of 0.25D. Measurements were taken on two occasions at each distance, which were separated by a time interval of at least 24 hours. Results: The measured amplitude at six metres was significantly lower than that with the target at 40cm, by 1.56 ± 1.17D (p < 0.001) and this varied between individuals (r = 0.716, intraclass correlation coefficient = 0.439). With either target distance, repeated measurement was highly correlated (r > 0.9) but the agreement was better at 6.0m (±0.74D) than at 40cm (± 0.92D). Conclusion: The measurements of the amplitude of accommodation with the minus lens technique using targets at far or near are not comparable and the difference between the target distances may provide clinically relevant information. © 2013 Optometrists Association Australia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background/aims Macular pigment is thought to protect the macula against exposure to light and oxidative stress, both of which may play a role in the development of age-related macular degeneration. The aim was to clinically evaluate a novel cathode-ray-tube-based method for measurement of macular pigment optical density (MPOD) known as apparent motion photometry (AMP). Methods The authors took repeat readings of MPOD centrally (0°) and at 3° eccentricity for 76 healthy subjects (mean (±SD) 26.5±13.2 years, range 18–74 years). Results The overall mean MPOD for the cohort was 0.50±0.24 at 0°, and 0.28±0.20 at 3° eccentricity; these values were significantly different (t=-8.905, p<0.001). The coefficients of repeatability were 0.60 and 0.48 for the 0 and 3° measurements respectively. Conclusions The data suggest that when the same operator is taking repeated 0° AMP MPOD readings over time, only changes of more than 0.60 units can be classed as clinically significant. In other words, AMP is not suitable for monitoring changes in MPOD over time, as increases of this magnitude would not be expected, even in response to dietary modification or nutritional supplementation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Between-participant research has shown that high negative affectivity predicts greater activity limitations and vice versa. This study examined both between- and within-participant associations of negative and positive affectivity with activity levels using ecological momentary assessment. Method: Participants were 25 people who had undergone joint replacement surgery 12 months previously. Participants made multiple reports of their activity and positive and negative affectivity over a single day using, a computerized diary. Activity was also objectively recorded using an activity monitor. The following day, participants made a self-report of their activity over the measurement day and general positive and negative affectivity levels were recorded. Results: Higher self-reported walking time over the whole measurement day was associated with higher general positive affectivity but not negative affectivity. However, using ecological momentary assessment, higher diary reports of negative affectivity predicted increased activity levels while positive affectivity neither predicted nor was predicted by activity. Conclusion: These findings demonstrate the importance of within-participant methodology in detecting subtle and immediate effects of individuals' mood on behavior that may differ from findings investigating between-participant effects over longer time periods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Anterior segment optical coherent tomography (AS-OCT, Visante; Zeiss) is used to examine meridional variation in anterior scleral thickness (AST) and its association with refractive error, ethnicity and gender. Scleral cross-sections of 74 individuals (28 males; 46 females; aged between 18-40 years (27.7±5.3)) were sampled twice in random order in 8 meridians: [superior (S), inferior (I), nasal (N), temporal (T), superior-temporal (ST), superior-nasal (SN), inferior-temporal (IT) and inferior-nasal (IN)]. AST was measured in 1mm anterior-toposterior increments (designated the A-P distance) from the scleral spur (SS) over a 6mm distance. Axial length and refractive error were measured with a Zeiss IOLMaster biometer and an open-view binocular Shin-Nippon autorefractor. Intra- And inter-observer variability of AST was assessed for each of the 8 meridians. Mixed repeated measures ANOVAs tested meridional and A-P distance differences in AST with refractive error, gender and ethnicity. Only right eye data were analysed. AST (mean±SD) across all meridians and A-P distances was 725±46μm. Meridian SN was the thinnest (662±57μm) and I the thickest (806 ±60μm). Significant differences were found between all meridians (p<0.001), except S:ST, IT:IN, IT:N and IN:N. Significant differences between A-P distances were found except between SS and 6 mm and between 2 and 4mm. AST measurements at 1mm (682±48 μm) were the thinnest and at 6mm (818±49 μm) the thickest (p<0.001); a significant interaction occurred between meridians and A-P distances (p<0.001). AST was significantly greater (p<0.001) in male subjects but no significant differences were found between refractive error or ethnicity. Significant variations in AST occur with regard to meridian and distance from the SS and may have utility in selecting optimum sites for pharmaceutical or surgical intervention.