5 resultados para removable appliance
em Aston University Research Archive
Resumo:
Suitable methods for the assessment of the effect of freeze-thaw action upon ceramic tiles have been determined. The results obtained have been shown to be reproducible with some work in this area still warranted. The analysis of Whichford Potteries clays via a variety of analytical techniques has shown them to be a complex mix of both clay and non-clay minerals. 57Fe Mössbauer spectroscopy has highlighted the presence of both small and large particleα-Fe203, removable via acid washing. 19F MAS NMR has demonstrated that the raw Whichford Pottery clays examined have negligible fluorine content. This is unlikely to be detrimental to ceramic wares during the heating process. A unique technique was used for the identification of fluorine in solid-state systems. The exchange of various cations into Wyoming Bentonite clay by microwave methodology did not show the appearance of five co-ordinate aluminium when examined by 27Al MAS NMR. The appearance of Qo silicate was linked to an increase in the amount of tetrahedrally bound aluminium in the silicate framework. This is formed as a result of the heating process. The analysis of two Chinese clays and two Chinese clay raw materials has highlighted a possible link between the two. These have also been shown to be a mix of both clay and non-clay minerals. Layered double hydroxides formed by conventional and microwave methods exhibited interesting characteristics. The main differences between the samples examined were not found to be solely attributable to the differences between microwave and conventional methods but more attributable to different experimental conditions used.
Resumo:
The suitability of a new plastic supporting medium for biofiltration was tested over a three year period. Tests were carried out on the stability, surface properties, mechanical strength, and dimensions of the medium. There was no evidence to suggest that the medium was deficient in any of these respects. The specific surface (320m2m-3) and the voidage (94%) of the new medium are unlike any other used in bio-filtration and a pilot plant containing two filters was built to observe its effects on ecology and performance. Performance was estimated by chemical analysis and ecology studied by film examination and fauna counts. A system of removable sampling baskets was designed to enable samples to be obtained from two intermediate depths of filter. One of the major operating problems of percolating filters is excessive accumulation of film. The amount of film is influenced by hydraulic and organic load and each filter was run at a different loading. One was operated at 1.2m3m-3day-1 (DOD load 0.24kgm-3day-1) judged at the time to be the lowest filtration rate to offer advantages over conventional media. The other filter was operated at more than twice this loading (2.4m3m-3day-lBOD load 0.55kgm-3day-1) giving a roughly 2.5x and 6x the conventional loadings recommended for a Royal Commission effluent. The amount of film in each filter was normally low (0.05-3kgm(3 as volatile solids) and did not affect efficiency. The evidence collected during the study indicated that the ecology of the filters was normal when compared with the data obtained from the literature relating to filters with mineral media. There were indications that full ecological stability was yet to be reached and this was affecting the efficiency of the filters. The lower rate filter produced an average 87% BOD removal giving a consistent Royal Commission effluent during the summer months. The higher rate filter produced a mean 83% BOD removal but at no stage a consistent Royal Commission effluent. From the data on ecology and performance the filters resembled conventional filters rather than high rate filters.
Resumo:
The work described in this thesis is directed towards the reduction of noise levels in the Hoover Turbopower upright vacuum cleaner. The experimental work embodies a study of such factors as the application of noise source identification techniques, investigation of the noise generating principles for each major source and evaluation of the noise reducing treatments. It was found that the design of the vacuum cleaner had not been optimised from the standpoint of noise emission. Important factors such as noise `windows', isolation of vibration at the source, panel rattle, resonances and critical speeds had not been considered. Therefore, a number of experimentally validated treatments are proposed. Their noise reduction benefit together with material and tooling costs are presented. The solutions to the noise problems were evaluated on a standard Turbopower and the sound power level of the cleaner was reduced from 87.5 dB(A) to 80.4 db(A) at a cost of 93.6 pence per cleaner.The designers' lack of experience in noise reduction was identified as one of the factors for the low priority given to noise during design of the cleaner. Consequently, the fundamentals of acoustics, principles of noise prediction and absorption and guidelines for good acoustical design were collated into a Handbook and circulated at Hoover plc.Mechanical variations during production of the motor and the cleaner were found to be important. These caused a vast spread in the noise levels of the cleaners. Subsequently, the manufacturing processes were briefly studied to identify their source and recommendations for improvement are made.Noise of a product is quality related and a high level of noise is considered to be a bad feature. This project suggested that the noise level be used constructively both as a test on the production line to identify cleaners above a certain noise level and also to promote the product by `designing' the characteristics of the sound so that the appliance is pleasant to the user. This project showed that good noise control principles should be implemented early in the design stage.As yet there are no mandatory noise limits or noise-labelling requirements for household appliances. However, the literature suggests that noise-labelling is likely in the near future and the requirement will be to display the A-weighted sound power level. However, the `noys' scale of perceived noisiness was found more appropriate to the rating of appliance noise both as it is linear and therefore, a sound level that seems twice as loud is twice the value in noys and also takes into consideration the presence of pure tones, which even in the absence of a high noise level can lead to annoyance.
Resumo:
Background - Inhibition of return (IOR) is thought to reflect inhibition of previously attended but irrelevant stimuli. Deficient IOR would increase the likelihood of revisiting previously searched locations or objects, thus leading to unproductive perseverations. Method - Therefore, using a novel IOR task, we investigated whether high scoring checkers attentional biases to threat would result in dysfunctional inhibitory functioning compared to low checkers. In two tasks, we compared 53 subclinical high and 49 low checkers regarding IOR effects for stimuli that were concordant with the concerns of high but not of low checkers (electrical kitchen appliances: e.g., toaster, kettle). The difference between the two tasks was the cueing procedure. In one task, an appliance was switched “ON” and “OFF” as an unpredictive cue, drawing attention to the functionality of the stimulus. Results - In this task, IOR was specifically attenuated in high checkers. In the other task, however, the cue was more abstract in form of a yellow outline that appeared around one of two appliances. Although the appliance was either “ON” or “OFF,” this did not seem to matter and high checkers revealed a typical IOR pattern similar to low checkers. Conclusions - We conclude that IOR mechanisms might not be generally deficient in high checkers; rather only when attention is drawn to the threatening aspects of ecologically valid stimuli, then disengagement of attention is deficient in high checkers. We make suggestions on how our task-specific findings may inform cognitive interventions that target attentional control in the treatment of checking/obsessive–compulsive disorder.
Resumo:
The treatment of presbyopia has been the focus of much scientific and clinical research over recent years, not least due to an increasingly aging population but also the desire for spectacle independence. Many lens and nonlens-based approaches have been investigated, and with advances in biomaterials and improved surgical methods, removable corneal inlays have been developed. One such development is the KAMRA™ inlay where a small entrance pupil is exploited to create a pinhole-type effect that increases the depth of focus and enables improvement in near visual acuity. Short- and long-term clinical studies have all reported significant improvement in near and intermediate vision compared to preoperative measures following monocular implantation (nondominant eye), with a large proportion of patients achieving Jaeger (J) 2 to J1 (~0.00 logMAR to ~0.10 logMAR) at the final follow-up. Although distance acuity is reduced slightly in the treated eye, binocular visual acuity and function remain very good (mean 0.10 logMAR or better). The safety of the inlay is well established and easily removable, and although some patients have developed corneal changes, these are clinically insignificant and the incidence appears to reduce markedly with advancements in KAMRA design, implantation technique, and femtosecond laser technology. This review aims to summarize the currently published peer-reviewed studies on the safety and efficacy of the KAMRA inlay and discusses the surgical and clinical outcomes with respect to the patient’s visual function.