10 resultados para quality testing
em Aston University Research Archive
Resumo:
Grounded in Vroom’s motivational framework of performance, we examine the interactive influence of collective human capital (ability) and aggregated service orientation (motivation) on the cross-level relationship between high-performance work systems (HPWS) and individual-level service quality. Results of hierarchical linear modeling (HLM) revealed that HPWS related to collective human capital and aggregated service orientation, which in turn related to individual-level service quality. Furthermore, both HLM and ordinary least squares regression analyses revealed a cross-level interaction effect of collective human capital and aggregated service orientation such that high levels of collective human capital and aggregated service orientation influence individual-level service quality.
Resumo:
This paper reports findings of a two year study concerning the development and implementation of a general-purpose computer-based assessment (CBA) system at a UK University. Data gathering took place over a period of nineteen months, involving a number of formative and summative assessments. Approximately 1,000 students, drawn from undergraduate courses, were involved in the exercise. The techniques used in gathering data included questionnaires, observation, interviews and an analysis of student scores in both conventional examinations and computer-based assessments. Comparisons with conventional assessment methods suggest that the use of CBA techniques may improve the overall performance of students. However it is clear that the technique must not be seen as a "quick fix" for problems such as rising student numbers. If one accepts that current systems test only a relatively narrow range of skills, then the hasty implementation of CBA systems will result in a distorted and inaccurate view of student performance. In turn, this may serve to reduce the overall quality of courses and - ultimately - detract from the student learning experience. On the other hand, if one adopts a considered and methodical approach to computer-based assessment, positive benefits might include increased efficiency and quality, leading to improved student learning.
Resumo:
Adopting an internal marketing approach, this paper attempts to provide a deeper understanding of the organisational commitment—service quality relationship in the service context. This is done by empirically testing the relationships that the three components of organisational commitment (affective, continuance and normative) have with the service quality of customer-contact employees. The hypotheses were framed by critically reviewing the extant literature in the areas of services marketing and human resource management. A large sample comparative study was conducted on employees in call centres and branches of a major retail bank in UK. We explore the important question of how the three components of organisational commitment influence the employee-perceived service quality differently in call centres and in branches. The findings indicate that in branches, both affective commitment and continuance commitment have significant positive impact on service quality while in call centres, only affective commitment is found to affect service quality significantly. Having established the commitment—service quality relationship, the implications for designing internal marketing strategies are further discussed.
Resumo:
Advances in technology coupled with increasing labour costs have caused service firms to explore self-service delivery options. Although some studies have focused on self-service and use of technology in service delivery, few have explored the role of service quality in consumer evaluation of technology-based self-service options. By integrating and extending the self-service quality framework the service evaluation model and the Technology Acceptance Model the authors address this emerging issue by empirically testing a comprehensive model that captures the antecedents and consequences of perceived service quality to predict continued customer interaction in the technology-based self-service context of Internet banking. Important service evaluation constructs like perceived risk, perceived value and perceived satisfaction are modelled in this framework. The results show that perceived control has the strongest influence on service quality evaluations. Perceived speed of delivery, reliability and enjoyment also have a significant impact on service quality perceptions. The study also found that even though perceived service quality, perceived risk and satisfaction are important predictors of continued interaction, perceived customer value plays a pivotal role in influencing continued interaction.
Resumo:
Visual perception is dependent on both light transmission through the eye and neuronal conduction through the visual pathway. Advances in clinical diagnostics and treatment modalities over recent years have increased the opportunities to improve the optical path and retinal image quality. Higher order aberrations and retinal straylight are two major factors that influence light transmission through the eye and ultimately, visual outcome. Recent technological advancements have brought these important factors into the clinical domain, however the potential applications of these tools and considerations regarding interpretation of data are much underestimated. The purpose of this thesis was to validate and optimise wavefront analysers and a new clinical tool for the objective evaluation of intraocular scatter. The application of these methods in a clinical setting involving a range of conditions was also explored. The work was divided into two principal sections: 1. Wavefront Aberrometry: optimisation, validation and clinical application The main findings of this work were: • Observer manipulation of the aberrometer increases variability by a factor of 3. • Ocular misalignment can profoundly affect reliability, notably for off-axis aberrations. • Aberrations measured with wavefront analysers using different principles are not interchangeable, with poor relationships and significant differences between values. • Instrument myopia of around 0.30D is induced when performing wavefront analysis in non-cyclopleged eyes; values can be as high as 3D, being higher as the baseline level of myopia decreases. Associated accommodation changes may result in relevant changes to the aberration profile, particularly with respect to spherical aberration. • Young adult healthy Caucasian eyes have significantly more spherical aberration than Asian eyes when matched for age, gender, axial length and refractive error. Axial length is significantly correlated with most components of the aberration profile. 2. Intraocular light scatter: Evaluation of subjective measures and validation and application of a new objective method utilising clinically derived wavefront patterns. The main findings of this work were: • Subjective measures of clinical straylight are highly repeatable. Three measurements are suggested as the optimum number for increased reliability. • Significant differences in straylight values were found for contact lenses designed for contrast enhancement compared to clear lenses of the same design and material specifications. Specifically, grey/green tints induced significantly higher values of retinal straylight. • Wavefront patterns from a commercial Hartmann-Shack device can be used to obtain objective measures of scatter and are well correlated with subjective straylight values. • Perceived retinal stray light was similar in groups of patients implanted with monofocal and multi focal intraocular lenses. Correlation between objective and subjective measurements of scatter is poor, possibly due to different illumination conditions between the testing procedures, or a neural component which may alter with age. Careful acquisition results in highly reproducible in vivo measures of higher order aberrations; however, data from different devices are not interchangeable which brings the accuracy of measurement into question. Objective measures of intraocular straylight can be derived from clinical aberrometry and may be of great diagnostic and management importance in the future.
Resumo:
Advocates of ‘local food’ claim it serves to reduce food miles and greenhouse gas emissions, improve food safety and quality, strengthen local economies and enhance social capital. We critically review the philosophical and scientific rationale for this assertion, and consider whether conventional scientific approaches can help resolve the debate. We conclude that food miles are a poor indicator of the environmental and ethical impacts of food production. Only through combining spatially explicit life cycle assessment with analysis of social issues can the benefits of local food be assessed. This type of analysis is currently lacking for nearly all food chains.
Resumo:
This research is focused on the optimisation of resource utilisation in wireless mobile networks with the consideration of the users’ experienced quality of video streaming services. The study specifically considers the new generation of mobile communication networks, i.e. 4G-LTE, as the main research context. The background study provides an overview of the main properties of the relevant technologies investigated. These include video streaming protocols and networks, video service quality assessment methods, the infrastructure and related functionalities of LTE, and resource allocation algorithms in mobile communication systems. A mathematical model based on an objective and no-reference quality assessment metric for video streaming, namely Pause Intensity, is developed in this work for the evaluation of the continuity of streaming services. The analytical model is verified by extensive simulation and subjective testing on the joint impairment effects of the pause duration and pause frequency. Various types of the video contents and different levels of the impairments have been used in the process of validation tests. It has been shown that Pause Intensity is closely correlated with the subjective quality measurement in terms of the Mean Opinion Score and this correlation property is content independent. Based on the Pause Intensity metric, an optimised resource allocation approach is proposed for the given user requirements, communication system specifications and network performances. This approach concerns both system efficiency and fairness when establishing appropriate resource allocation algorithms, together with the consideration of the correlation between the required and allocated data rates per user. Pause Intensity plays a key role here, representing the required level of Quality of Experience (QoE) to ensure the best balance between system efficiency and fairness. The 3GPP Long Term Evolution (LTE) system is used as the main application environment where the proposed research framework is examined and the results are compared with existing scheduling methods on the achievable fairness, efficiency and correlation. Adaptive video streaming technologies are also investigated and combined with our initiatives on determining the distribution of QoE performance across the network. The resulting scheduling process is controlled through the prioritization of users by considering their perceived quality for the services received. Meanwhile, a trade-off between fairness and efficiency is maintained through an online adjustment of the scheduler’s parameters. Furthermore, Pause Intensity is applied to act as a regulator to realise the rate adaptation function during the end user’s playback of the adaptive streaming service. The adaptive rates under various channel conditions and the shape of the QoE distribution amongst the users for different scheduling policies have been demonstrated in the context of LTE. Finally, the work for interworking between mobile communication system at the macro-cell level and the different deployments of WiFi technologies throughout the macro-cell is presented. A QoEdriven approach is proposed to analyse the offloading mechanism of the user’s data (e.g. video traffic) while the new rate distribution algorithm reshapes the network capacity across the macrocell. The scheduling policy derived is used to regulate the performance of the resource allocation across the fair-efficient spectrum. The associated offloading mechanism can properly control the number of the users within the coverages of the macro-cell base station and each of the WiFi access points involved. The performance of the non-seamless and user-controlled mobile traffic offloading (through the mobile WiFi devices) has been evaluated and compared with that of the standard operator-controlled WiFi hotspots.
Resumo:
In this paper a full analytic model for pause intensity (PI), a no-reference metric for video quality assessment, is presented. The model is built upon the video play out buffer behavior at the client side and also encompasses the characteristics of a TCP network. Video streaming via TCP produces impairments in play continuity, which are not typically reflected in current objective metrics such as PSNR and SSIM. Recently the buffer under run frequency/probability has been used to characterize the buffer behavior and as a measurement for performance optimization. But we show, using subjective testing, that under run frequency cannot reflect the viewers' quality of experience for TCP based streaming. We also demonstrate that PI is a comprehensive metric made up of a combination of phenomena observed in the play out buffer. The analytical model in this work is verified with simulations carried out on ns-2, showing that the two results are closely matched. The effectiveness of the PI metric has also been proved by subjective testing on a range of video clips, where PI values exhibit a good correlation with the viewers' opinion scores. © 2012 IEEE.
Resumo:
Purpose: To examine visual outcomes following bilateral implantation of the FineVision trifocal intraocular lens (IOL; PhysIOL, Liège, Belgium). Methods: 26 patients undergoing routine cataract surgery were implanted bilaterally with the FineVision Trifocal IOL and followed up post-operatively for 3 months. The FineVision optic features a combination of 2 diffractive structures, resulting in distance, intermediate (+1.75 D add) and near vision (+3.50 D add) zones. Apodization of the optic surface increases far vision dominance with pupil aperture. Data collected at the 3 month visit included uncorrected and corrected distance (CDVA) and near vision; subjective refraction; defocus curve testing (photopic and mesopic); contrast sensitivity (CSV-1000); halometry glare testing and a questionnaire (NAVQ) to gauge near vision function and patient satisfaction. Results: The cohort comprised 15 males and 11 females, aged 52.5–82.4 years (mean 70.6 ± 8.2 years). Mean post-operative UDVA was 0.22 ± 0.14 logMAR, with a mean spherical equivalent refraction of +0.02 ± 0.35 D. Mean CDVA was 0.13 ± 0.10 logMAR monocularly, and 0.09 ± 0.07 logMAR binocularly. Defocus curve testing showed an extensive range of clear vision in both photopic and mesopic conditions. Patients showed high levels of satisfaction with their near vision (mean ± 0.9 ± 0.6, where 0 = completely satisfied, and 4 = completely unsatisfied) and demonstrated good spectacle independence. Conclusion: The FineVision IOL can be considered in patients seeking spectacle dependence following cataract surgery, and provide good patient satisfaction with uncorrected vision.
Resumo:
In this work we deal with video streams over TCP networks and propose an alternative measurement to the widely used and accepted peak signal to noise ratio (PSNR) due to the limitations of this metric in the presence of temporal errors. A test-bed was created to simulate buffer under-run in scalable video streams and the pauses produced as a result of the buffer under-run were inserted into the video before being employed as the subject of subjective testing. The pause intensity metric proposed in [1] was compared with the subjective results and it was shown that in spite of reductions in frame rate and resolution, a correlation with pause intensity still exists. Due to these conclusions, the metric may be employed in layer selection in scalable video streams. © 2011 IEEE.