18 resultados para pure spinors

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the first recording of a periodic structure of ∼150 nm pitch in a permanently moving sample of a pure fused silica using the tightly focused, 82 nJ, 267 nm, 300 fs, 1 kHz laser pulses. © 2007 IOP Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability to recognize individual faces is of crucial social importance for humans and evolutionarily necessary for survival. Consequently, faces may be “special” stimuli, for which we have developed unique modular perceptual and recognition processes. Some of the strongest evidence for face processing being modular comes from cases of prosopagnosia, where patients are unable to recognize faces whilst retaining the ability to recognize other objects. Here we present the case of an acquired prosopagnosic whose poor recognition was linked to a perceptual impairment in face processing. Despite this, she had intact object recognition, even at a subordinate level. She also showed a normal ability to learn and to generalize learning of nonfacial exemplars differing in the nature and arrangement of their parts, along with impaired learning and generalization of facial exemplars. The case provides evidence for modular perceptual processes for faces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fabrication of sub-micron periodic structures beyond diffraction limit is a major motivation for the present paper. We describe the fabrication of the periodic structure of 25 mm long with a pitch size of 260 nm which is less than a third of the wavelength used. This is the smallest reported period of the periodic structure inscribed by direct point-by-point method. A prototype of the add-drop filter, which utilizes such gratings, was demonstrated in one stage fabrication process of femtosecond inscription, in the bulk fused silica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fabrication of sub-micron periodic structures beyond diffraction limit is a major motivation for the present paper. We describe the fabrication of the periodic structure of 25 mm long with a pitch size of 260 nm which is less than a third of the wavelength used. This is the smallest reported period of the periodic structure inscribed by direct point-by-point method. A prototype of the add-drop filter, which utilizes such gratings, was demonstrated in one stage fabrication process of femtosecond inscription, in the bulk fused silica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Very recently, using tightly-focused femtosecond near-IR pulses, periodical sub-micron structures have been recorded [1,2]. Such microfabrication utilizes the multi-photon approach, which allows the inscription inside various non-photosensitive optical materials. The combination of multi-photon excitation with the point-by-point technique offers the great potential of creating non-uniform chirped gratings by controlling the rate of femtosecond pulses or the sample translation speed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the first recording of a periodic structure of ~150 nm pitch in a permanently moving sample of a pure fused silica using the tightly focused, 82 nJ, 267 nm, 300 fs, 1 kHz laser pulses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sudden change applied to a single component can cause its segregation from an ongoing complex tone as a pure-tone-like percept. Three experiments examined whether such pure-tone-like percepts are organized into streams by extending the research of Bregman and Rudnicky (1975). Those authors found that listeners struggled to identify the presentation order of 2 pure-tone targets of different frequency when they were flanked by 2 lower frequency “distractors.” Adding a series of matched-frequency “captor” tones, however, improved performance by pulling the distractors into a separate stream from the targets. In the current study, sequences of discrete pure tones were substituted by sequences of brief changes applied to an otherwise constant 1.2-s complex tone. Pure-tone-like percepts were evoked by applying 6-dB increments to individual components of a complex comprising harmonics 1–7 of 300 Hz (Experiment 1) or 0.5-ms changes in interaural time difference to individual components of a log-spaced complex (range 160–905 Hz; Experiment 2). Results were consistent with the earlier study, providing clear evidence that pure-tone-like percepts are organized into streams. Experiment 3 adapted Experiment 1 by presenting a global amplitude increment either synchronous with, or just after, the last captor prior to the 1st distractor. In the former case, for which there was no pure-tone-like percept corresponding to that captor, the captor sequence did not aid performance to the same extent as previously. It is concluded that this change to the captor-tone stream partially resets the stream-formation process, and so the distractors and targets became likely to integrate once more. (PsycINFO Database Record (c) 2011 APA, all rights reserved)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a novel tunable dispersion compensator that can provide pure slope compensation. The approach uses two specially designed complex fiber Bragg gratings (FBGs) with reversely varied third-order group delay curves to generate the dispersion slope. The slope can be changed by adjusting the relative wavelength positions of the two FBGs. Several design examples of such complex gratings are presented and discussed. Experimentally, we achieve a dispersion slope tuning range of +/-650ps/nm2 with >0.9nm usable bandwidth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In biaxial compression tests, the stress calculations based on boundary information underestimate the principal stresses leading to a significant overestimation of the shear strength. In direct shear tests, the shear strain becomes highly concentrated in the mid-plane of the sample during the test. Although the stress distribution within the specimen is heterogeneous, the evolution of the stress ratio inside the shear band is similar to that inferred from the boundary force calculations. It is also demonstrated that the dilatancy in the shear band significantly exceeds that implied from the boundary displacements. In simple shear tests, the stresses acting on the wall boundaries do not reflect the internal state of stress but merely provide information about the average mobilised wall friction. It is demonstrated that the results are sensitive to the initial stress state defined by K0 = sh/sv. For all cases, non-coaxiality of the principal stress and strain-rate directions is examined and the corresponding flow rule is identified. Periodic cell simulations have been used to examine biaxial compression for a wide range of initial packing densities. Both constant volume and constant mean stress tests have been simulated. The characteristic behaviour at both the macroscopic and microscopic scales is determined by whether or not the system percolates (enduring connectivity is established in all directions). The transition from non-percolating to percolating systems is characterised by transitional behaviour of internal variables and corresponds to an elastic percolation threshold, which correlates well with the establishment of a mechanical coordination number of ca. 3.0. Strong correlations are found between macroscopic and internal variables at the critical state.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Silicone elastomers are commonly used in the manufacture of single-piece joint replacement implants for the finger joints. However, the survivorship of these implants can be poor, with failure typically occurring from fracture of the stems. The aim of this paper was to investigate the crack growth of medical-grade silicone using pure shear tests. Two medical-grade silicones (C6-180 and Med82-5010-80) were tested. Each sample had a 20 mm crack introduced and was subjected to a sinusoidally varying tensile strain, with a minimum of 0 per cent and a maximum in the range 10 to 77 per cent. Testing was undertaken at a frequency of 10 Hz. At various times during testing, the testing machine was stopped, the number of cycles completed was noted, and the crack length measured. Graphs of crack length against number of cycles were plotted, as well as the crack growth rate against tearing energy. The results show that Med82-5010-80 is more crack resistant than C6-180. Graphs of crack growth rate against tearing energy can be used to predict the failure of these medical-grade elastomers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a polygeneration system that can run on neat plant oils, such as Jatropha and Pongamia, or standard diesel fuel. A prototype has been constructed using a compression ignition engine of 9.9 kW shaft output. It consumes 3 L/h of fuel and will produce 40 kg/h of ice by means of an adsorption refrigerator powered from the engine jacket heat. Steaming of rice, deep and shallow frying, and other types of food preparation heated by the exhaust gas have been demonstrated. In addition, the feasibility of producing distilled water by means of multiple-effect distillation powered by the engine waste heat is shown. Overall plant efficiency and potential savings in greenhouse gas emissions are discussed. © 2012 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Signal resolution in H NMR is limited primarily by multiplet structure. Recent advances in pure shift NMR, in which the effects of homonuclear couplings are suppressed, have allowed this limitation to be circumvented in 1D NMR, gaining almost an order of magnitude in spectral resolution. Here for the first time an experiment is demonstrated that suppresses multiplet structure in both domains of a homonuclear two-dimensional spectrum. The principle is demonstrated for the TOCSY experiment, generating a chemical shift correlation map in which a single peak is seen for each coupled relationship, but the principle is general and readily extensible to other homonuclear correlation experiments. Such spectra greatly simplify manual spectral analysis and should be well-suited to automated methods for structure elucidation. © 2010 American Chemical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we investigate the impact of minute amounts of pure nitrogen addition into conventional methane/hydrogen mixtures on the growth characteristics of nanocrystalline diamond (NCD) films by microwave plasma assisted chemical vapour deposition (MPCVD), under high power conditions. The NCD films were produced from a gas mixture of 4% CH4/H2 with two different concentrations of N2 additive and microwave power ranging from 3.0 kW to 4.0 kW, while keeping all the other operating parameters constant. The morphology, grain size, microstructure and texture of the resulting NCD films were characterized by using scanning electron microscope (SEM), micro-Raman spectroscopy and X-ray diffraction (XRD) techniques. N2 addition was found to be the main parameter responsible for the formation and for the key change in the growth characteristics of NCD films under the employed conditions. Growth rates ranging from 5.4 μm/h up to 9.6 μm/h were achieved for the NCD films, much higher than those usually reported in the literature. The enhancing factor of nitrogen addition on NCD growth rate was obtained by comparing with the growth rate of large-grained microcrystalline diamond films grown without nitrogen and discussed by comparing with that of single crystal diamond through theoretical work in the literature. This achievement on NCD growth rate makes the technology interesting for industrial applications where fast coating of large substrates is highly desirable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Very recently, using tightly-focused femtosecond near-IR pulses, periodical sub-micron structures have been recorded [1,2]. Such microfabrication utilizes the multi-photon approach, which allows the inscription inside various non-photosensitive optical materials. The combination of multi-photon excitation with the point-by-point technique offers the great potential of creating non-uniform chirped gratings by controlling the rate of femtosecond pulses or the sample translation speed.