24 resultados para prosthesis fit

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the critical fitting characteristics of modern soft contact lens fits and from this to devise a simplified recording scheme. Methods: Ten subjects (aged 28.1 ± 7.4 years) wore eight different modern soft contact lenses. Video was captured and analysed of blink (central and up-gaze), excursion lag (up, down, right and left gaze) and push-up movement, centration and coverage. Results: Lens centration was on average close to the corneal centre. Movement on blink was significantly smaller in up-gaze than in primary-gaze (p<0.001). Lag was greatest in down-gaze and least in up-gaze (p<0.001). Push-up test recovery speed was 1.32±0.73mm/s. Overall lens movement was determined best by assessing horizontal lag, movement on blink in up-gaze and push-up recovery speed. Steeper lens base-curves did not have a significant effect on lens fit characteristics. Contact lens material did influence lens fit characteristics, particularly silicone-hydrogels which generally had lower centration and a faster push-up speed of recovery than HEMA lenses (p<0.05). Conclusion: Lag on vertical gaze, and movement on blink in primary gaze generally provide little extra information on overall lens movement compared to horizontal lag, movement on blink in up gaze and push-up recovery speed. They can therefore be excluded from a simplified recording scheme. A simplified and comprehensive soft contact lens fit recording system could consist of a cross-hairs indicating the centre of the cornea; a circle to indicate the lens centration; a mark on the relevant position of the circle to indicate any limbal incursion; a grade (‘B’) below for movement with blink in up-gaze, a grade (‘L’) to the side for horizontal lag and a grade above (‘P’) for the assessed push-up recovery speed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the influence of peripheral ocular topography, as evaluated by optical coherence tomography (OCT), compared with traditional measures of corneal profile using keratometry and videokeratoscopy, on soft contact lens fit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, Drǎgulescu and Yakovenko proposed an analytical formula for computing the probability density function of stock log returns, based on the Heston model, which they tested empirically. Their research design inadvertently favourably biased the fit of the data to the Heston model, thus overstating their empirical results. Furthermore, Drǎgulescu and Yakovenko did not perform any goodness-of-fit statistical tests. This study employs a research design that facilitates statistical tests of the goodness-of-fit of the Heston model to empirical returns. Robustness checks are also performed. In brief, the Heston model outperformed the Gaussian model only at high frequencies and even so does not provide a statistically acceptable fit to the data. The Gaussian model performed (marginally) better at medium and low frequencies, at which points the extra parameters of the Heston model have adverse impacts on the test statistics. © 2005 Taylor & Francis Group Ltd.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sponsorship fit is frequently mentioned and empirically examined as a success factor of sponsorship. While sponsorship fit has been considered as a determinant of sponsorship success, little knowledge exists about the antecedents of sponsorship fit. In the present paper, individual and firm-level antecedents of sponsorship fit are examined in a single hierarchical linear model. Results show that sponsorship fit is influenced by the perception of benefits, the firm’s regional identification, sincerity, relatedness to the sponsored activity, and its dominance. On a partnership level, results show that contract length contributes to sponsorship fit while contract value is found to be unrelated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To develop a new schematic scheme for efficiently recording the key parameters of gas permeable contact lens (GP) fits based on current consensus. Methods: Over 100 established GP fitters and educators met to discuss the parameters proposed in educational material for evaluating GP fit and concluded on the key parameters that should be recorded. The accuracy and variability of evaluating the fluorescein pattern of GP fit was determined by having 35 experienced contact lens practitioners from across the world, grading 5 images of a range of fits and the topographer simulation of the same fits, in random, order using the proposed scheme. The accuracy of the grading was compared to objective image analysis of the fluorescein intensity of the same images. Results: The key information to record to adequately describe the fit of an GP was agreed as: the manufacturer, brand and lens parameters; settling time; comfort on a 5 point scale; centration; movement on blink on a ±2 scale; and the Primary Fluorescein Pattern in the central, mid-peripheral and edge regions of the lens averaged along the horizontal and vertical lens axes, on a ±2 scale. On average 50-60% of practitioners selected the median grade when subjectively rating fluorescein intensity and this was correlated to objective quantification (r= 0.602, p< 0.001). Objective grading suggesting horizontal median fluorescein intensity was generally symmetrical, as was the vertical meridian, but this was not the case for subjective grading. Simulated fluorescein patterns were subjectively and objectively graded as being less intense than real photographs (p< 0.01). Conclusion: GP fit recording can be standardised and simplified to enhance GP practice. © 2013 British Contact Lens Association.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the recent rapid growth of the Semantic Web (SW), the processes of searching and querying content that is both massive in scale and heterogeneous have become increasingly challenging. User-friendly interfaces, which can support end users in querying and exploring this novel and diverse, structured information space, are needed to make the vision of the SW a reality. We present a survey on ontology-based Question Answering (QA), which has emerged in recent years to exploit the opportunities offered by structured semantic information on the Web. First, we provide a comprehensive perspective by analyzing the general background and history of the QA research field, from influential works from the artificial intelligence and database communities developed in the 70s and later decades, through open domain QA stimulated by the QA track in TREC since 1999, to the latest commercial semantic QA solutions, before tacking the current state of the art in open user-friendly interfaces for the SW. Second, we examine the potential of this technology to go beyond the current state of the art to support end-users in reusing and querying the SW content. We conclude our review with an outlook for this novel research area, focusing in particular on the R&D directions that need to be pursued to realize the goal of efficient and competent retrieval and integration of answers from large scale, heterogeneous, and continuously evolving semantic sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article is a first step towards addressing a gap in the field of organisational resilience research by examining how small and medium enterprises (SME) manage the threat and actuality of extreme events. Pilot research found that the managerial framing of extreme events varied by a range of organisational factors. This finding informed further examination of the contextual nature of the resilience concept. To date, large organisations have been the traditional focus of empirical work and theorising in this area; yet the heterogeneous SME sector makes up approximately 99% of UK industry and routinely operates under conditions of uncertainty. In a comparative study examining UK organisational resilience, it emerged that SME participants had both a distinctive perspective and approach to resilience when compared to participants from larger organisations. This article presents a subset of data from 11 SME decision-makers. The relationship between resilience capabilities, such as flexibility and adaptation, is interrogated in relation to organisational size. The data suggest limitations of applying a one-size-fits-all organisation solution (managerial or policy) to creating resilience. This study forms the basis for survey work examining the extent to which resilience is an organisationally contingent concept in practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In previous Statnotes, many of the statistical tests described rely on the assumption that the data are a random sample from a normal or Gaussian distribution. These include most of the tests in common usage such as the ‘t’ test ), the various types of analysis of variance (ANOVA), and Pearson’s correlation coefficient (‘r’) . In microbiology research, however, not all variables can be assumed to follow a normal distribution. Yeast populations, for example, are a notable feature of freshwater habitats, representatives of over 100 genera having been recorded . Most common are the ‘red yeasts’ such as Rhodotorula, Rhodosporidium, and Sporobolomyces and ‘black yeasts’ such as Aurobasidium pelculans, together with species of Candida. Despite the abundance of genera and species, the overall density of an individual species in freshwater is likely to be low and hence, samples taken from such a population will contain very low numbers of cells. A rare organism living in an aquatic environment may be distributed more or less at random in a volume of water and therefore, samples taken from such an environment may result in counts which are more likely to be distributed according to the Poisson than the normal distribution. The Poisson distribution was named after the French mathematician Siméon Poisson (1781-1840) and has many applications in biology, especially in describing rare or randomly distributed events, e.g., the number of mutations in a given sequence of DNA after exposure to a fixed amount of radiation or the number of cells infected by a virus given a fixed level of exposure. This Statnote describes how to fit the Poisson distribution to counts of yeast cells in samples taken from a freshwater lake.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy service companies (ESCOs) are faced with a range of challenges and opportunities associated with the rapidly changing and flexible requirements of energy customers (end users) and rapid improvements in technologies associated with energy and ICT. These opportunities for innovation include better prediction of energy demand, transparency of data to the end user, flexible and time dependent energy pricing and a range of novel finance models. The liberalisation of energy markets across the world has leads to a very small price differential between suppliers on the unit cost of energy. Energy companies are therefore looking to add additional layers of value using service models borrowed from the manufacturing industry. This opens a range of new product and service offerings to energy markets and consumers and has implications for the overall efficiency, utility and price of energy provision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The principal theme of this thesis is the identification of additional factors affecting, and consequently to better allow, the prediction of soft contact lens fit. Various models have been put forward in an attempt to predict the parameters that influence soft contact lens fit dynamics; however, the factors that influence variation in soft lens fit are still not fully understood. The investigations in this body of work involved the use of a variety of different imaging techniques to both quantify the anterior ocular topography and assess lens fit. The use of Anterior-Segment Optical Coherence Tomography (AS-OCT) allowed for a more complete characterisation of the cornea and corneoscleral profile (CSP) than either conventional keratometry or videokeratoscopy alone, and for the collection of normative data relating to the CSP for a substantial sample size. The scleral face was identified as being rotationally asymmetric, the mean corneoscleral junction (CSJ) angle being sharpest nasally and becoming progressively flatter at the temporal, inferior and superior limbal junctions. Additionally, 77% of all CSJ angles were within ±50 of 1800, demonstrating an almost tangential extension of the cornea to form the paralimbal sclera. Use of AS-OCT allowed for a more robust determination of corneal diameter than that of white-to-white (WTW) measurement, which is highly variable and dependent on changes in peripheral corneal transparency. Significant differences in ocular topography were found between different ethnicities and sexes, most notably for corneal diameter and corneal sagittal height variables. Lens tightness was found to be significantly correlated with the difference between horizontal CSJ angles (r =+0.40, P =0.0086). Modelling of the CSP data gained allowed for prediction of up to 24% of the variance in contact lens fit; however, it was likely that stronger associations and an increase in the modelled prediction of variance in fit may have occurred had an objective method of lens fit assessment have been made. A subsequent investigation to determine the validity and repeatability of objective contact lens fit assessment using digital video capture showed no significant benefit over subjective evaluation. The technique, however, was employed in the ensuing investigation to show significant changes in lens fit between 8 hours (the longest duration of wear previously examined) and 16 hours, demonstrating that wearing time is an additional factor driving lens fit dynamics. The modelling of data from enhanced videokeratoscopy composite maps alone allowed for up to 77% of the variance in soft contact lens fit, and up to almost 90% to be predicted when used in conjunction with OCT. The investigations provided further insight into the ocular topography and factors affecting soft contact lens fit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To examine the optimum time at which fluorescein patterns of gas permeable lenses (GPs) should be evaluated. METHODS: Aligned, 0.2mm steep and 0.2mm flat GPs were fitted to 17 patients (aged 20.6±1.1 years, 10 male). Fluorescein was applied to their upper temporal bulbar conjunctiva with a moistened fluorescein strip. Digital slit lamp images (CSO, Italy) at 10× magnification of the fluorescein pattern viewed with blue light through a yellow filter were captured every 15s. Fluorescein intensity in central, mid peripheral and edge regions of the superior, inferior, temporal and nasal quadrants of the lens were graded subjectively using a +2 to -2 scale and using ImageJ software on the simultaneously captured images. RESULTS: Subjectively graded and objectively image analysed fluorescein intensity changed with time (p<0.001), lens region (centre, mid-periphery and edge: p<0.05) and there was interaction between lens region with lens fit (p<0.001). For edge band width, there was a significant effect of time (F=118.503, p<0.001) and lens fit (F=5.1249, p=0.012). The expected alignment, flat and steep fitting patterns could be seen from approximately after 30 to 180s subjectively and 15 to 105s in captured images. CONCLUSION: Although the stability of fluorescein intensity can start to decline in as little as 45s post fluorescein instillation, the diagnostic pattern of alignment, steep or flat fit is seen in each meridian by subjective observation from about 30s to 3min indicating this is the most appropriate time window to evaluate GP lenses in clinical practice.