19 resultados para pressure analysis

em Aston University Research Archive


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This thesis was concerned with investigating methods of improving the IOP pulse’s potential as a measure of clinical utility. There were three principal sections to the work. 1. Optimisation of measurement and analysis of the IOP pulse. A literature review, covering the years 1960 – 2002 and other relevant scientific publications, provided a knowledge base on the IOP pulse. Initial studies investigated suitable instrumentation and measurement techniques. Fourier transformation was identified as a promising method of analysing the IOP pulse and this technique was developed. 2. Investigation of ocular and systemic variables that affect IOP pulse measurements In order to recognise clinically important changes in IOP pulse measurement, studies were performed to identify influencing factors. Fourier analysis was tested against traditional parameters in order to assess its ability to detect differences in IOP pulse. In addition, it had been speculated that the waveform components of the IOP pulse contained vascular characteristic analogous to those components found in arterial pulse waves. Validation studies to test this hypothesis were attempted. 3. The nature of the intraocular pressure pulse in health and disease and its relation to systemic cardiovascular variables. Fourier analysis and traditional parameters were applied to the IOP pulse measurements taken on diseased and healthy eyes. Only the derived parameter, pulsatile ocular blood flow (POBF) detected differences in diseased groups. The use of an ocular pressure-volume relationship may have improved the POBF measure’s variance in comparison to the measurement of the pulse’s amplitude or Fourier components. Finally, the importance of the driving force of pulsatile blood flow, the arterial pressure pulse, is highlighted. A method of combining the measurements of pulsatile blood flow and pulsatile blood pressure to create a measure of ocular vascular impedance is described along with its advantages for future studies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present an experimental and numerical study of transversely loaded uniform fibre-Bragg gratings. A novel loading configuration is described, producing pressure-induced spectral holes in an initially strong uniform grating. The birefringence properties of these gratings are analysed. It is shown that the frequency splitting of the two spectral holes, corresponding to two orthogonal polarisation states, can be adjusted precisely using this loading configuration. We finally demonstrate a new and simple scheme to induce multiple spectral holes in the stop-band. © 2003 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate the relationship between ocular perfusion pressure and color Doppler measurements in patients with glaucoma. MATERIALS AND METHODS: Twenty patients with primary open-angle glaucoma with visual field deterioration in spite of an intraocular pressure lowered below 21 mm Hg, 20 age-matched patients with glaucoma with stable visual fields, and 20 age-matched healthy controls were recruited. After a 20-minute rest in a supine position, intraocular pressure and color Doppler measurements parameters of the ophthalmic artery and the central retinal artery were obtained. Correlations between mean ocular perfusion pressure and color Doppler measurements parameters were determined. RESULTS: Patients with glaucoma showed a higher intraocular pressure (P <.0008) and a lower mean ocular perfusion pressure (P <.0045) compared with healthy subjects. Patients with deteriorating glaucoma showed a lower mean blood pressure (P =.033) and a lower end diastolic velocity in the central retinal artery (P =.0093) compared with normals. Mean ocular perfusion pressure correlated positively with end diastolic velocity in the ophthalmic artery (R = 0.66, P =.002) and central retinal artery (R = 0.74, P <.0001) and negatively with resistivity index in the ophthalmic artery (R = -0.70, P =.001) and central retinal artery (R = -0.62, P =.003) in patients with deteriorating glaucoma. Such correlations did not occur in patients with glaucoma with stable visual fields or in normal subjects. The correlations were statistically significantly different between the study groups (parallelism of regression lines in an analysis of covariance model) for end diastolic velocity (P =.001) and resistivity index (P =.0001) in the ophthalmic artery, as well as for end diastolic velocity (P =.0009) and resistivity index (P =. 001) in the central retinal artery. CONCLUSIONS: The present findings suggest that alterations in ocular blood flow regulation may contribute to the progression in glaucomatous damage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To assess whether blood pressure control in primary care could be improved with the use of patient held targets and self monitoring in a practice setting, and to assess the impact of these on health behaviours, anxiety, prescribed antihypertensive drugs, patients' preferences, and costs. DESIGN: Randomised controlled trial. SETTING: Eight general practices in south Birmingham. PARTICIPANTS: 441 people receiving treatment in primary care for hypertension but not controlled below the target of < 140/85 mm Hg. INTERVENTIONS: Patients in the intervention group received treatment targets along with facilities to measure their own blood pressure at their general practice; they were also asked to visit their general practitioner or practice nurse if their blood pressure was repeatedly above the target level. Patients in the control group received usual care (blood pressure monitoring by their practice). MAIN OUTCOME MEASURES: Primary outcome: change in systolic blood pressure at six months and one year in both intervention and control groups. Secondary outcomes: change in health behaviours, anxiety, prescribed antihypertensive drugs, patients' preferences of method of blood pressure monitoring, and costs. RESULTS: 400 (91%) patients attended follow up at one year. Systolic blood pressure in the intervention group had significantly reduced after six months (mean difference 4.3 mm Hg (95% confidence interval 0.8 mm Hg to 7.9 mm Hg)) but not after one year (mean difference 2.7 mm Hg (- 1.2 mm Hg to 6.6 mm Hg)). No overall difference was found in diastolic blood pressure, anxiety, health behaviours, or number of prescribed drugs. Patients who self monitored lost more weight than controls (as evidenced by a drop in body mass index), rated self monitoring above monitoring by a doctor or nurse, and consulted less often. Overall, self monitoring did not cost significantly more than usual care (251 pounds sterling (437 dollars; 364 euros) (95% confidence interval 233 pounds sterling to 275 pounds sterling) versus 240 pounds sterling (217 pounds sterling to 263 pounds sterling). CONCLUSIONS: Practice based self monitoring resulted in small but significant improvements of blood pressure at six months, which were not sustained after a year. Self monitoring was well received by patients, anxiety did not increase, and there was no appreciable additional cost. Practice based self monitoring is feasible and results in blood pressure control that is similar to that in usual care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The literature on the potential use of liquid ammonia as a solvent for the extraction of aromatic hydrocarbons from mixtures with paraffins, and the application of reflux, has been reviewed. Reference is made to extractors suited to this application. A pilot scale extraction plant was designed comprising a Scm. diameter by 12Scm. high, 50 stage Rotating Disc Contactor with 2 external settlers. Provision was made for operation with, or without, reflux at a pressure of 10 bar and ambient temperature. The solvent recovery unit consisted of an evaporator, compressor and condenser in a refrigeration cycle. Two systems were selected for study, Cumene-n-Heptane-Ammonia and Toluene-Methylcyclohexane-Ammonia. Equlibrium data for the first system was determined experimentally in a specially-designed, equilibrium bomb. A technique was developed to withdraw samples under pressure for analysis by chromatography and titration. The extraction plant was commissioned with a kerosine-water system; detailed operating procedures were developed based on a Hazard and Operability Study. Experimental runs were carried out with both ternary ammonia systems. With the system Toluene-Methylcyclohexane-Ammonia the extraction plant and the solvent recovery facility, operated satisfactorily, and safely,in accordance with the operating procedures. Experimental data gave reasonable agreement with theory. Recommendations are made for further work with plant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Optometrists are becoming more integrally involved in the diagnosis of and care for glaucoma patients in the UK. The correlation of apparent change in non contact tonometry (NCT) IOP measurement and change in other ocular parameters such as refractive error, corneal curvature, corneal thickness and treatment zone size (data available to optometrists after LASIK) would facilitate care of these patients. Setting: A UK Laser Eye Clinic. Methods: This is a retrospective study study of 200 sequential eyes with myopia with or without astigmatism which underwent LASIK using a Hansatome and an Alcon LADARvision 4000 excimer laser. Refraction keratometry, pachymetry and NCT IOP mesurements were taken before treatmebnt and agian 3 months after treatment. The relationship between these variables anfd teh treatment zones were studied using stepwise multiple regression analysis. Results: There was a mean difference of 5.54mmHg comnparing pre and postoperative NCT IOP. IOP change correlates with refractive error change (P < 0.001), preoperative corneal thickness (P < 0.001) and treatment zone size (P = 0.047). Preoperative corneal thickness correlates with preoperative IOP (P < 0.001) and postoperative IOP (P < 0.001). Using these correlations, the measured difference in NCT IIOP can be predicted preoperatively or postoperatively using derived equations.Conclusion: There is a significant reduction in measured NCT IOP after LASIK. The amount of reduction can be calculated using data acquired by optometrists. This is helpful for opthalmologists and optometrists who co-manage glaucoma patients who have had LASIK or with glaucoma pateints who are consideraing having LASIK.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A study has been made, using High Pressure Liquid Chromatography, of the migration of TMQ (a quinoline type) and 6PPD (a paraphenylenediamine type) antidegradants from a tyre sidewall compound into adjacent casing and liner compounds containing no antidegradant. Migration takes place at a rapid rate, even during the vulcanisation of the composite. After 4000 hours ageing in nitrogen at 100oC, there is a higher level of antidegradants in the casing than in the sidewall. An equilibrium distribution is not obtained. After 114 days at 50oC in 95% relative humidity, the level of solvent extractable 6PPD fell to zero, but subsequent ageing for 2 years in 50 pphm ozone showed no evidence of sidewall cracking. It is suggested that the antidegradant is still active but linked to the polymer chain. An analytical method, for the type and amount of sulphenamide accelerators in vulcanised rubber compounds, has been developed. During the vulcanisation process, the accelerators decay, liberating specific amines which have been solvent extracted, derivatised with 1-chloro-2,4-dinitrobenzene and the yellow coloured zwitter ion analysed using High Pressure Liquid Chromatography. The decay of the accelerator and sulphur during the vulcanisation process, has been studied. It has been demonstrated that the sulphur crosslinking with a styrenebutadiene polymer is a first order reaction, after an initial period during which the accelerator content falls to zero. Variations in sulphur to accelerator ratios gave consistent rate constants for the crosslinking, except for a sulphur level of less than 1% by weight and a ratiio of accelerator to sulphur of 1:1.3. The retention time of the reaction product between sulphur and accelerator from an HPLC column changes with cure time, showing that the precurser to crosslinking is an ever changing material. One of these reaction products has been analysed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Due to the failure of PRARE the orbital accuracy of ERS-1 is typically 10-15 cm radially as compared to 3-4cm for TOPEX/Poseidon. To gain the most from these simultaneous datasets it is necessary to improve the orbital accuracy of ERS-1 so that it is commensurate with that of TOPEX/Poseidon. For the integration of these two datasets it is also necessary to determine the altimeter and sea state biases for each of the satellites. Several models for the sea state bias of ERS-1 are considered by analysis of the ERS-1 single satellite crossovers. The model adopted consists of the sea state bias as a percentage of the significant wave height, namely 5.95%. The removal of ERS-1 orbit error and recovery of an ERS-1 - TOPEX/Poseidon relative bias are both achieved by analysis of dual crossover residuals. The gravitational field based radial orbit error is modelled by a finite Fourier expansion series with the dominant frequencies determined by analysis of the JGM-2 co-variance matrix. Periodic and secular terms to model the errors due to atmospheric density, solar radiation pressure and initial state vector mis-modelling are also solved for. Validation of the dataset unification consists of comparing the mean sea surface topographies and annual variabilities derived from both the corrected and uncorrected ERS-1 orbits with those derived from TOPEX/Poseidon. The global and regional geographically fixed/variable orbit errors are also analysed pre and post correction, and a significant reduction is noted. Finally the use of dual/single satellite crossovers and repeat pass data, for the calibration of ERS-2 with respect to ERS-1 and TOPEX/Poseidon is shown by calculating the ERS-1/2 sea state and relative biases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The relationship between accommodation and intraocular pressure (lOP) has not been addressed as a research question for over 20 years, when measurement of both of these parameters was less advanced than today. Hence the central aim of this thesis was to evaluate the effects of accommodation on lOP. The instrument of choice throughout this thesis was the Pulsair EasyEye non-contact tonometer (NCT) due principally to its slim-line design which allowed the measurement of lOP in one eye and simultaneous stimulation of accommodation in the other eye. A second reason for using the Pulsair EasyEye NCT was that through collaboration with the manufacturers (Keeler, UK) the instrument's operational technology was made accessible. Hence, the principle components underpinning non-contact lOP measures of 0.1mmHg resolution (an order of magnitude greater than other methods) were made available. The relationship between the pressure-output and corneal response has been termed the pressure-response relationship, aspects of which have been shown to be related to ocular biometric parameters. Further, analysis of the components of the pressure-response relationship together with high-speed photography of the cornea during tonometry has enhanced our understanding of the derivation of an lOP measure with the Pulsair EasyEye NCT. The NCT samples the corneal response to the pressure pulse over a 19 ms cycle photoelectronically, but computes the subject's lOP using the data collected in the first 2.34 ms. The relatively instantaneous nature of the lOP measurement renders the measures susceptible to variations in the steady-state lOP caused by the respiratory and cardiac cycles. As such, the variance associated with these cycles was minimised by synchronising the lOP measures with the cardiac trace and maintaining a constant pace respiratory cycle at 15 breathes/minute. It is apparent that synchronising the lOP measures with the peak, middle or trough of the cardiac trace significantly reduced the spread of consecutive measures. Of the 3 locations investigated, synchronisation with the middle location demonstrated the least variance (coeflicient of variation = 9.1%) and a strong correlation (r = 0.90, p = <0.001) with lOP values obtained with Goldmann contact tonometry (n = 50). Accordingly lOP measures synchronised with the middle location of the cardiac cycle were taken in the RE while the LE fixated low (L; zero D), intermediate (I; 1.50 D) and high (H; 4 D) accommodation targets, Quasi-continuous measures of accommodation responses were obtained during the lOP measurement period using the portable infrared Grand Seiko FR-5000 autorefractor. The lOP reduced between L and I accommodative levels by approximately 0.61 mmHg (p <0.00 I). No significant reduction in IOP between L and H accommodation levels was elicited (p = 0.65) (n = 40). The relationship between accommodation and lOP was characterised by substantial inter-subject variations. Myopes demonstrated a tendency to show a reduction in IOP with accommodation which was significant only with I accommodation levels when measured with the NCT (r = 0.50, p = 0.01). However, the relationship between myopia and lOP change with accommodation reached significance for both I (r = 0.61, p= 0.003) and H (r = 0.531, p= 0.0 1) accommodation levels when measured with the Ocular blood Flow Analyser (OBFA). Investigation of the effects of accommodation on the parameters measured by the OBFA demonstrated that with H accommodation levels the pulse amplitude (PA) and pulse rate (PR) responses differed between myopes and emmetropes (PA: p = 0.03; PR: p = 0.004). As thc axial length increased there was a tendency for the pulsatile ocular blood flow (POBF) to reduce with accommodation, which was significant only with H accommodation levels (r = 0.38, p = 0.02). It is proposed that emmetropes arc able to regulate the POBF responses to changes in ocular perfusion pressure caused by changes in lOP with I (r = 0.77, p <0.001) and H (r = 0.73, p = 0.001) accommodation levels. However, thc relationship between lOP and POBF changes in the myopes was not correlated for both I (r = 0.33, p = 0.20) and H (r = 0.05, p = 0.85) accommodation levels. The thesis presents new data on the relationships between accommodation, lOP and parameters of the OBFA,: and provides evidence for possible lOP and choroidal blood flow regulatory mechanisms. Further the data highlight possible deficits in the vascular regulation of the myopic eye during accommodation, which may play a putative role in the aetiology of myopia development.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis documents an investigation of the effect of solar radiation pressure on the motion of an artificial satellite. Consideration is given to the methods required for the inclusion of the discontinuous effect of the Earth's shadow. The analysis resulting from the description of a deformed diffusely reflecting balloon satellite and an algorithm describing the effects of Earth reflected solar radiation pressure are developed, culminating in the application of the derived theory to the orbital data of the balloon satellite, Explorer 19.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to gain a greater understanding of firms' 'environmental behaviour' this paper explores the factors that influence firms' emissions intensities and provides the first analysis of the determinants of firm level carbon dioxide (CO2) emissions. Focussing on Japan, the paper also examines whether firms' CO2 emissions are influenced by the emissions of neighbouring firms and other possible sources of spatial correlation. Results suggest that size, the capital-labour ratio, R&D expenditure, the extent of exports and concern for public profile are the key determinants of CO2 emissions. Local lobbying pressure, as captured by regional community characteristics, does not appear to play a role, however emissions are found to be spatially correlated. This raises implications for the manner in which the environmental performance of firms is modelled in future. © 2013 Elsevier Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Maize is the main staple food for most Kenyan households, and it predominates where smallholder, as well as large-scale, farming takes place. In the sugarcane growing areas of Western Kenya, there is pressure on farmers on whether to grow food crops, or grow sugarcane, which is the main cash crop. Further, with small and diminishing land sizes, the question of productivity and efficiency, both for cash and food crops is of great importance. This paper, therefore, uses a two-step estimation technique (DEA meta-frontier and Tobit Regression) to highlight the inefficiencies in maize cultivation, and their causes in Western Kenya.