29 resultados para point-of-care testing

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The goal of evidence-based medicine is to uniformly apply evidence gained from scientific research to aspects of clinical practice. In order to achieve this goal, new applications that integrate increasingly disparate health care information resources are required. Access to and provision of evidence must be seamlessly integrated with existing clinical workflow and evidence should be made available where it is most often required - at the point of care. In this paper we address these requirements and outline a concept-based framework that captures the context of a current patient-physician encounter by combining disease and patient-specific information into a logical query mechanism for retrieving relevant evidence from the Cochrane Library. Returned documents are organized by automatically extracting concepts from the evidence-based query to create meaningful clusters of documents which are presented in a manner appropriate for point of care support. The framework is currently being implemented as a prototype software agent that operates within the larger context of a multi-agent application for supporting workflow management of emergency pediatric asthma exacerbations. © 2008 Springer-Verlag Berlin Heidelberg.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: The objective of this research was to design a clinical decision support system (CDSS) that supports heterogeneous clinical decision problems and runs on multiple computing platforms. Meeting this objective required a novel design to create an extendable and easy to maintain clinical CDSS for point of care support. The proposed solution was evaluated in a proof of concept implementation. METHODS: Based on our earlier research with the design of a mobile CDSS for emergency triage we used ontology-driven design to represent essential components of a CDSS. Models of clinical decision problems were derived from the ontology and they were processed into executable applications during runtime. This allowed scaling applications' functionality to the capabilities of computing platforms. A prototype of the system was implemented using the extended client-server architecture and Web services to distribute the functions of the system and to make it operational in limited connectivity conditions. RESULTS: The proposed design provided a common framework that facilitated development of diversified clinical applications running seamlessly on a variety of computing platforms. It was prototyped for two clinical decision problems and settings (triage of acute pain in the emergency department and postoperative management of radical prostatectomy on the hospital ward) and implemented on two computing platforms-desktop and handheld computers. CONCLUSIONS: The requirement of the CDSS heterogeneity was satisfied with ontology-driven design. Processing of application models described with the help of ontological models allowed having a complex system running on multiple computing platforms with different capabilities. Finally, separation of models and runtime components contributed to improved extensibility and maintainability of the system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evidence-based medicine relies on repositories of empirical research evidence that can be used to support clinical decision making for improved patient care. However, retrieving evidence from such repositories at local sites presents many challenges. This paper describes a methodological framework for automatically indexing and retrieving empirical research evidence in the form of the systematic reviews and associated studies from The Cochrane Library, where retrieved documents are specific to a patient-physician encounter and thus can be used to support evidence-based decision making at the point of care. Such an encounter is defined by three pertinent groups of concepts - diagnosis, treatment, and patient, and the framework relies on these three groups to steer indexing and retrieval of reviews and associated studies. An evaluation of the indexing and retrieval components of the proposed framework was performed using documents relevant for the pediatric asthma domain. Precision and recall values for automatic indexing of systematic reviews and associated studies were 0.93 and 0.87, and 0.81 and 0.56, respectively. Moreover, precision and recall for the retrieval of relevant systematic reviews and associated studies were 0.89 and 0.81, and 0.92 and 0.89, respectively. With minor modifications, the proposed methodological framework can be customized for other evidence repositories. © 2010 Elsevier Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The diagnosis of ocular disease is increasingly important in optometric practice and there is a need for cost effective point of care assays to assist in that. Although tears are a potentially valuable source of diagnostic information difficulties associated with sample collection and limited sample size together with sample storage and transport have proved major limitations. Progressive developments in electronics and fibre optics together with innovation in sensing technology mean that the construction of inexpensive point of care fibre optic sensing devices is now possible. Tear electrolytes are an obvious family of target analytes, not least to complement the availability of devices that make the routine measurement of tear osmolarity possible in the clinic. In this paper we describe the design, fabrication and calibration of a fibre-optic based electrolyte sensor for the quantification of potassium in tears using the ex vivo contact lens as the sample source. The technology is generic and the same principles can be used in the development of calcium and magnesium sensors. An important objective of this sensor technology development is to provide information at the point of routine optometric examination, which would provide supportive evidence of tear abnormality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A significant body of research investigates the acceptance of computer-based support (including devices and applications ranging from e-mail to specialized clinical systems, like PACS) among clinicians. Much of this research has focused on measuring the usability of systems using characteristics related to the clarity of interactions and ease of use. We propose that an important attribute of any clinical computer-based support tool is the intrinsic motivation of the end-user (i.e. a clinician) to use the system in practice. In this paper we present the results of a study that investigated factors motivating medical doctors (MDs) to use computer-based support. Our results demonstrate that MDs value computer-based support, find it useful and easy to use, however, uptake is hindered by perceived incompetence, and pressure and tension associated with using technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Hospital discharge is a transition of care, where medication discrepancies are likely to occur and potentially cause patient harm. The purpose of our study was to assess the prescribing accuracy of hospital discharge medication orders at a London, UK teaching hospital. The timeliness of the discharge summary reaching the general practitioner (GP, family physician) was also assessed based on the 72 h target referenced in the Care Quality Commission report.1 Method: 501 consecutive discharge medication orders from 142 patients were examined and the following records were compared (1) the final inpatient drug chart at the point of discharge, (2) printed signed copy of the initial to take away (TTA) discharge summary produced electronically by the physician, (3) the pharmacist's amendments on the initial TTA that were hand written, (4) the final electronic patient discharge summary record, (5) the patients final take home medication from the hospital. Discrepancies between the physician's order (6) and pharmacist's change(s) (7) were compared with two types of failures – ‘failure to make a required change’ and ‘change where none was required’. Once the patient was discharged, the patient's GP, was contacted 72 h after discharge to see if the patient discharge summary, sent by post or via email, was received. Results: Over half the patients seen (73 out of 142) patients had at least one discrepancy that was made on the initial TTA by the doctor and amended by the pharmacist. Out of the 501 drugs, there were 140 discrepancies, 108 were ‘failures to make a required change’ (77%) and 32 were ‘changes where none were required’ (23%). The types of ‘failures to make required changes’ discrepancies that were found between the initial TTA and pharmacist's amendments were paracetamol and ibuprofen changes (dose banding) 38 (27%), directions of use 34 (24%), incorrect formulation of medication 28 (20%) and incorrect strength 8 (6%). The types of ‘changes where none were required discrepancies’ were omitted medication 15 (11%), unnecessary drug 14 (10%) and incorrect medicine including spelling mistakes 3 (2%). After contacting the GPs of the discharged patients 72 h postdischarge; 49% had received the discharge summary and 45% had not, the remaining 6% were patients who were discharged without a GP. Conclusion: This study shows that doctor prescribing at discharge is often not accurate, and interventions made by pharmacist to reconcile are important at this point of care. It was also found that half the discharge summaries had not reached the patient's family physician (according to the GP) within 72 h.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Self-testing technology allows people to test themselves for chlamydia without professional support. This may result in reassurance and wider access to chlamydia testing, but anxiety could occur on receipt of positive results. This study aimed to identify factors important in understanding self-testing for chlamydia outside formal screening contexts, to explore the potential impacts of self-testing on individuals, and to identify theoretical constructs to form a Framework for future research and intervention development. Methods: Eighteen university students participated in semi-structured interviews; eleven had self-tested for chlamydia. Data were analysed thematically using a Framework approach. Results: Perceived benefits of self-testing included its being convenient, anonymous and not requiring physical examination. There was concern about test accuracy and some participants lacked confidence in using vulvo-vaginal swabs. While some participants expressed concern about the absence of professional support, all said they would seek help on receiving a positive result. Factors identified in Protection Motivation Theory and the Theory of Planned Behaviour, such as response efficacy and self-efficacy, were found to be highly salient to participants in thinking about self-testing. Conclusions: These exploratory findings suggest that self-testing independently of formal health care systems may no more negatively impact people than being tested by health care professionals. Participants’ perceptions about self-testing behaviour were consistent with psychological theories. Findings suggest that interventions which increase confidence in using self-tests and that provide reassurance of test accuracy may increase self-test intentions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Political discourse very often relies on translation. Political Discourse Analysis (PDA), however, has not yet taken full account of the phenomenon of translation. This paper argues that the disciplines of Translation Studies (TS) and PDA can benefit from closer cooperation. It starts by presenting examples of authentic translations of political texts, commenting on them from the point of view of TS. These examples concern political effects caused by specific translation solutions; the processes by which information is transferred via translation to another culture; and the structure and function of equally valid texts in their respective cultures. After a brief survey of the discipline of Translation Studies, the paper concludes with outlining scope for interdisciplinary cooperation between PDA and TS. This is illustrated with reference to an awareness of product features, multilingual texts, process analysis, and the politics of translation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effectiveness of rapid and controlled heating of intact tissue to inactivate native enzymatic activity and prevent proteome degradation has been evaluated. Mouse brains were bisected immediately following excision, with one hemisphere being heat treated followed by snap freezing in liquid nitrogen while the other hemisphere was snap frozen immediately. Sections were cut by cryostatic microtome and analyzed by MALDI-MS imaging and minimal label 2-D DIGE, to monitor time-dependent relative changes in intensities of protein and peptide signals. Analysis by MALDI-MS imaging demonstrated that the relative intensities of markers varied across a time course (0-5 min) when the tissues were not stabilized by heat treatment. However, the same markers were seen to be stabilized when the tissues were heat treated before snap freezing. Intensity profiles for proteins indicative of both degradation and stabilization were generated when samples of treated and nontreated tissues were analyzed by 2-D DIGE, with protein extracted before and after a 10-min warming of samples. Thus, heat treatment of tissues at the time of excision is shown to prevent subsequent uncontrolled degradation of tissues at the proteomic level before any quantitative analysis, and to be compatible with downstream proteomic analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The subject of investigation of the present research is the use of smart hydrogels with fibre optic sensor technology. The aim was to develop a costeffective sensor platform for the detection of water in hydrocarbon media, and of dissolved inorganic analytes, namely potassium, calcium and aluminium. The fibre optic sensors in this work depend upon the use of hydrogels to either entrap chemotropic agents or to respond to external environmental changes, by changing their inherent properties, such as refractive index (RI). A review of current fibre optic technology for sensing outlined that the main principles utilised are either the measurement of signal loss or a change in wavelength of the light transmitted through the system. The signal loss principle relies on changing the conditions required for total internal reflection to occur. Hydrogels are cross-linked polymer networks that swell but do not dissolve in aqueous environments. Smart hydrogels are synthetic materials that exhibit additional properties to those inherent in their structure. In order to control the non-inherent properties, the hydrogels were fabricated with the addition of chemotropic agents. For the detection of water, hydrogels of low refractive index were synthesized using fluorinated monomers. Sulfonated monomers were used for their extreme hydrophilicity as a means of water sensing through an RI change. To enhance the sensing capability of the hydrogel, chemotropic agents, such as pH indicators and cobalt salts, were used. The system comprises of the smart hydrogel coated onto an exposed section of the fibre optic core, connected to the interrogation system measuring the difference in the signal. Information obtained was analysed using a purpose designed software. The developed sensor platform showed that an increase in the target species caused an increase in the signal lost from the sensor system, allowing for a detection of the target species. The system has potential applications in areas such as clinical point of care, water detection in fuels and the detection of dissolved ions in the water industry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A description of the background to testing friction materials for automotive brakes explains the need for a rapid, inexpensive means of assessing their behaviour in a way which is both accurate and meaningful. Various methods of controlling inertia dynamometers to simulate road vehicles are rejected in favour of programming by means of a commercially available XY plotter. Investigation of brake service conditions is used to set up test schedules, and a dynamometer programming unit built to enable service conditions on vehicles to be simulated on a full scale dynamometer. A technique is developed by which accelerated testing can be achieved without operating under overload conditions, saving time and cost without sacrificing validity. The development of programming by XY plotter is described, with a method of operating one XY plotter to programme the machine, monitor its own behaviour, and plot its own results in logical sequence. Commissioning trials are described and the generation of reproducible results in frictional behaviour and material durability is discussed. Teclmiques are developed to cross check the operation of the machine in retrospect, and retrospectively correct results in the event of malfunctions. Sensitivity errors in the measuring circuits are displayed between calibrations, whilst leaving the recorded results almost unaffected by error. Typical results of brake lining tests are used to demonstrate the range of performance parameters which can be studied by use of the machine. Successful test investigations completed on the machine are reported, including comments on behaviour of cast iron drums and discs. The machine shows that materials can repeat their complex friction/ temperature/speed/pressure relationships at a reproducibility of the order of +-0.003u and +~ 0.0002 in. thickness loss during wear tests. Discussion of practical and academic implications completes the report with recommendations for further work in both fields.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study examines factors influencing language planning decisions in contemporary France. It focuses upon the period 1992-1994, which witnessed the introduction of two major language policy measures, the first an amendment to the French Constitution, in 1992, proclaiming the language of the Republic as French, the second, in 1994, legislation to extend the ambit of the loi Bas-Lauriol, governing the use of the French language in France. The thesis posits a significant role for the pro-reform movement led by the French language association Avenir de la Langue Francaise (ALF) in the introduction and formulation of the policy measures concerned. The movement is depicted as continuing the traditional pattern of intellectual involvement in language planning, whilst also marking the beginning of a highly proactive, and increasingly political approach. Detailed examination of the movement's activities reveals that contextual factors and strategic strength combined to facilitate access to the levers of power, and enabled those involved to exert an impact on policy initiation, formulation, and ultimately implementation. However, ALF's decision to pursue the legislative route led to the expansion of the network of actors involved in language policymaking, and the development of counter-pressure from sectoral groups. It is suggested that this more interventionist approach destabilised the traditionally consensual language policy community, and called into question the quasi-monopoly of the intelligentsia in respect of language policymaking. It raised broader questions relating to freedom of expression and the permissible limits of language regulation in a democracy such as France. It also exposed ongoing ambiguities and inconsistencies in the interpretation of the tenets of language planning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Soft contact lenses for continuous wear require the use of cleaning regimes which utilise hydrogen peroxide systems or multipurpose cleaning solutions (MPS). The compositions of MPS are becoming increasingly complex and often include disinfectants, cleaning agents, preservatives, wetting agents, demulcents, chelating and buffering agents. Recent research on solution–lens interactions has focused on specific ocular parameters such as corneal staining. However the effect of a solution on the lens, particularly silicone hydrogel lenses, itself has received less attention. The purpose of this work was to establish and understand the effects that care solutions have on selected bulk and surface material properties. Methods: Selected bulk and surface properties of each material (etafilcon A, vifilcon A, balafilcon A, senofilcon A, lotrafilcon A and lotrafilcon B, galyfilcon A) were measured after a 24 h soak in a variety of care solutions. Additionally the lenses were soaked for 24 h in hyperosmolar (680 mOsm L-1) and hyposmolar (170 mOsm L-1) PBS. A bulk property parameter the total diameter (TD) was measured using an Optimec contact lens analyser. The surface property related CoF of soaked lenses was measured on a nano-tribometer with conditions of load 30 mN, at a distance of 20 mm and speed 30 mm/min. Results: In terms of bulk properties, change is related to the EWC of the lens, the higher the EWC of the lens the greater the TD changes. Silicone hydrogel lenses have EWCs of <47% and little or no TD changes were observed; lotrafilcon A exhibited no change irrespective of the cleaning solution. Conventional contact lenses have higher EWCs (58% for etafilcon A and 55% for vifilcon A) and the TD was seen to change to a greater extent, for example the etafilcon A material in ReNu MPS had an increase to 14.45± 0.07 mm from the cited 14.2 mm. Other lenses increased or decreased in TD depending on the solution used. The osmolarity of the solution although important is not the only factor governing change in the TD, for example soaking senofilcon A in hyperosmolar PBS (680 mOsm L-1) for 24 h increased the TD of the lens (+0.25 ± 0.07 mm), however when the same lens type was soaked for 24 h in a MPS with a lower osmolarity there was a similar effect. Biotribology measurements demonstrated that some solution–lens combinations can reduce the CoF by 55%, when compared with biotribology with the native packing solution. An increase in the CoF was observed for other solution–lens combinations. Conclusions: There is a dramatic difference in bulk and surface performance of specific lens materials with particular care solutions. Individual components of the care solutions have effects on the bulk and surface properties of contact lenses. The affects are not as great with the silicone hydrogel as compared with conventional hydrogels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Product Service Systems (PSSs) emphasize the substitution of products with services. The term “Servitisation” was introduced by Sandra Vendermerwe in the 80s to represent the addition of services to increase a company’s competitive edge. Key to PSS, and Servitisation more generally, is the “informated product”. The informated product enables health monitoring of the product in use and can be key to a workable PSS. This paper reviews the evolution of servitisation and the associated business benefit. It also then reviews the concept of informated product reconfiguration techniques and remote services that enables PSS to be delivered.