5 resultados para plethysmography.

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of in-line curvature sensors on a garment are used to monitor the thoracic and abdominal movements of a human during respiration. These results are used to obtain volumetric tidal changes of the human torso in agreement with a spirometer used simultaneously at the mouth. The curvature sensors are based on long-period gratings (LPGs) written in a progressive three-layered fiber to render the LPGs insensitive to the refractive index external to the fiber. A curvature sensor consists of the fiber long-period grating laid on a carbon fiber ribbon, which is then encapsulated in a low-temperature curing silicone rubber. The sensors have a spectral sensitivity to curvature, d lambda/dR from similar to 7-nm m to similar to 9-nm m. The interrogation technique is borrowed from derivative spectroscopy and monitors the changes in the transmission spectral profile of the LPG's attenuation band due to curvature. The multiplexing of the sensors is achieved by spectrally matching a series of distributed feedback (DFB) lasers to the LPGs. The versatility of this sensing garment is confirmed by it being used on six other human subjects covering a wide range of body mass indices. Just six fully functional sensors are required to obtain a volumetric error of around 6%. (C) 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Preliminary results are given for a long period grating sensing array scheme based upon a derivative spectroscopy interrogation technique for Human Respiratory Plethysmography with simultaneous measurements of a spirometer, reasonable agreement with recorded volumetric changes was found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of in-line curvature sensors on a garment are used to monitor the thoracic and abdominal movements of a human during respiration. These results are used to obtain volumetric tidal changes of the human torso in agreement with a spirometer used simultaneously at the mouth. The curvature sensors are based on long-period gratings (LPGs) written in a progressive three-layered fiber to render the LPGs insensitive to the refractive index external to the fiber. A curvature sensor consists of the fiber long-period grating laid on a carbon fiber ribbon, which is then encapsulated in a low-temperature curing silicone rubber. The sensors have a spectral sensitivity to curvature, dλ/dR from ∼7-nm m to ∼9-nm m. The interrogation technique is borrowed from derivative spectroscopy and monitors the changes in the transmission spectral profile of the LPG's attenuation band due to curvature. The multiplexing of the sensors is achieved by spectrally matching a series of distributed feedback (DFB) lasers to the LPGs. The versatility of this sensing garment is confirmed by it being used on six other human subjects covering a wide range of body mass indices. Just six fully functional sensors are required to obtain a volumetric error of around 6%. © 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Respiration is a complex activity. If the relationship between all neurological and skeletomuscular interactions was perfectly understood, an accurate dynamic model of the respiratory system could be developed and the interaction between different inputs and outputs could be investigated in a straightforward fashion. Unfortunately, this is not the case and does not appear to be viable at this time. In addition, the provision of appropriate sensor signals for such a model would be a considerable invasive task. Useful quantitative information with respect to respiratory performance can be gained from non-invasive monitoring of chest and abdomen motion. Currently available devices are not well suited in application for spirometric measurement for ambulatory monitoring. A sensor matrix measurement technique is investigated to identify suitable sensing elements with which to base an upper body surface measurement device that monitors respiration. This thesis is divided into two main areas of investigation; model based and geometrical based surface plethysmography. In the first instance, chapter 2 deals with an array of tactile sensors that are used as progression of existing and previously investigated volumetric measurement schemes based on models of respiration. Chapter 3 details a non-model based geometrical approach to surface (and hence volumetric) profile measurement. Later sections of the thesis concentrate upon the development of a functioning prototype sensor array. To broaden the application area the study has been conducted as it would be fore a generically configured sensor array. In experimental form the system performance on group estimation compares favourably with existing system on volumetric performance. In addition provides continuous transient measurement of respiratory motion within an acceptable accuracy using approximately 20 sensing elements. Because of the potential size and complexity of the system it is possible to deploy it as a fully mobile ambulatory monitoring device, which may be used outside of the laboratory. It provides a means by which to isolate coupled physiological functions and thus allows individual contributions to be analysed separately. Thus facilitating greater understanding of respiratory physiology and diagnostic capabilities. The outcome of the study is the basis for a three-dimensional surface contour sensing system that is suitable for respiratory function monitoring and has the prospect with future development to be incorporated into a garment based clinical tool.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cardiovascular disease (CVD) is the leading cause of death in Europe responsible for more than 4.3 million deaths annually. The World Health Organisation funded the Monica project (1980s-1990s) which monitored ten million subjects aged 22-6Syrs, and demonstrated that coronary heart disease (CHD) mortality declined over 10 years, was due in two thirds of cases to reduced incidence of CHD (reduced risk behaviours e.g. poor diet and smoking) and one third by improved treatments. Epidemiological evidence suggests diets rich in antioxidants decrease incidence of CVD. Regular consumption of nuts, rich in vitamin E and polyphenols reduces atherosclerosis, an important risk for heart disease. Intervention studies to date using alpha tocopherol (an active component of vitamin E) have not consistently proved beneficial. This thesis aims to investigate the effect of almond supplementation on vascular risk factors in healthy young males (18-3Syrs); mature males and female(>SOyrs); and males considered at increased risk of CVD (18-3Syrs) in a cohort of 67 subjects. The effects of almond intake were assessed after 2Sg/d for four weeks followed by SOg/d for four weeks and compared to a control group which did not consume almonds or change their diet. Cardiovascular risk was assessed by plasma lipid profiles, apolipoprotein A1, plasma nitrates/nitrates, vascular flow, BMl, blood pressure, sVCAM-1 and protein oxidation. Systolic and diastolic blood pressures were reduced in almond supplemented volunteers but not in controls. Dietary monounsaturated fatty acids, polyunsaturated fatty acid content and total dietary fats were increased by almond supplementation. Neither sVCAM-1, venous occlusion plethysmography nor plasma nitrite levels were affected by almond intake in any independent group. No significant changes in plasma lipids, and apolipoprotein A1 were observed. In conclusion almonds supplementation caused a reduction in blood pressure that may be due to increased sensitivity of the baroreceptors after increased monounsaturated fatty acid intake.