3 resultados para physiological sensors

em Aston University Research Archive


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mechanical physiological pulsations are movements of a body surface incited by the movements of muscles in organs inside the body. Here we demonstrate the use of long-period grating sensors in the detection of cardio-vascular pulsations (CVP), in particular apex and carotid pulsations. To calibrate the sensors, we use a mechanical tool designed specifically to measure the sensor response to a localized perturbation at different grating curvatures as working points. From the data we infer the amplitude of the CVP. Together with the electrophysiological signals, the CVP signals obtained from the sensors can provide significant information on heart function which is inaccessible to the electrocardiogram. The low cost and easy handling of the fibre sensors increase their prospects to become the sensors of choice for novel diagnostic devices. © 2013 The Royal Swedish Academy of Sciences.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigated which evoked response component occurring in the first 800 ms after stimulus presentation was most suitable to be used in a classical P300-based brain-computer interface speller protocol. Data was acquired from 275 Magnetoencephalographic sensors in two subjects and from 61 Electroencephalographic sensors in four. To better characterize the evoked physiological responses and minimize the effect of response overlap, a 1000 ms Inter Stimulus Interval was preferred to the short (

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Opto-acoustic imaging is a growing field of research in recent years, providing functional imaging of physiological biomarkers, such as the oxygenation of haemoglobin. Piezo electric transducers are the industry standard detector for ultrasonics, but their limited bandwidth, susceptibility to electromagnetic interference and their inversely proportional sensitivity to size all affect the detector performance. Sensors based on polymer optical fibres (POF) are immune to electromagnetic interference, have lower acoustic impedance and a reduced Young's Modulus compared to silica fibres. Furthermore, POF enables the possibility of a wideband sensor and a size appropriate to endoscopy. Micro-structured POF (mPOF) used in an interferometric detector has been shown to be an order of magnitude more sensitive than silica fibre at 1 MHz and 3 times more sensitive at 10 MHz. We present the first opto-acoustic measurements obtained using a 4.7mm PMMA mPOF Bragg grating with a fibre diameter of 130 μm and present the lateral directivity pattern of a PMMA mPOF FBG ultrasound sensor over a frequency range of 1-50 MHz. We discuss the impact of the pattern with respect to the targeted application and draw conclusions on how to mitigate the problems encountered.