3 resultados para photochromic
em Aston University Research Archive
Resumo:
Purpose: To investigate the effects of light filters on reading speed in normal and low vision due to age-related macular degeneration (AMD). Methods: Reading speed was determined for 12 subjects with normal vision and 12 subjects with non-exudative AMD using stationary lowercase nonsensical print in Times Roman font and four light filters; a yellow Corning Photochromic Filter (CPF) 450, a grey neural density (ND) filter, an individual filter obtained using the Intuitive Colorimeter® and a clear filter. Results: There was no statistically significant light filter effect on reading speed for the normal subjects. The AMD group demonstrated a statistically significant 5% average improvement in reading speed with the CPF450 compared with the other filters although some AMD subjects had improvements of 10-15%. Conclusions: Light filters obtained using the Intuitive Colorimeter® performed poorly when compared with the CPF450, ND and clear filters for both the study groups. For the AMD group, average reading speed was statistically greater with the CPF450 than the other filters, however it is questionable whether the improvement (5%) would be clinically significant. As some of the subjects with AMD had greater improvements with the CPF450 we advocate clinical assessment of light filters using existing protocols on an individual basis. © 2004 The College of Optometrists.
Resumo:
A literature review revealed that very little work has been conducted to investigate the possible benefits of coloured interventions on reading performance in low vision due to ARMD, under conditions that are similar to the real world reading environment. Further studies on the use of colour, as a rehabilitative intervention in low vision would therefore be useful. A series of objective, subject based, age-similar controlled experiments were used to address the primary aims. Trends in some of the ARMD data suggested better reading performance with blue or green illuminance but there were also some individuals who performed better with yellow, or with illuminance of reduced intensity. Statistically, better reading in general occurred with a specialised yellow photochromic lens and also a clear lens than with a fixed lens or a neutral density filter. No reading advantage was gained from using the coloured screen facility of a video-magnifier. Some subjects with low vision were found to have co-existent binocular vision anomalies, which may have caused reading difficulties similar to those produced by ARMD. Some individuals with ARMD benefited from the use of increased local illuminance produced by either a standard tungsten or compact fluorescent lamp. No reading improvement occurred with a daylight simulation tungsten lamp. The Intuitive Colorimeter® can be used to detect and map out colour vision discrimination deficiency in ARMD and the Humphrey 630 Visual Field Analyser can be used to analyse the biocular visual field in subjects with ARMD. Some experiments highlighted a positive effect of a blue intervention in reading with ARMD.
Resumo:
Background Yellow filters are sometimes recommended to people with low vision. Our aim was investigate the effects of three commercial yellow filters on visual acuity and contrast sensitivity (with and without glare) and reading (without glare) under conditions of forward light scatter (FLS). Method Fifty-five healthy subjects were assessed with Corning Photochromic Filters (CPFs) 450, 511 and 527 and a filter producing FLS. The effects on log MAR visual acuity, Pelli–Robson contrast sensitivity with and without glare, and reading (measured with MNRead charts) without glare were determined. Results Statistically significant differences were found between the overall effect of glare and between CPFs for visual acuity and contrast sensitivity. A gradual decline in visual acuity, contrast sensitivity and reading with increasing CPF absorption was noted. Conclusion Effects of CPF450, 511, 527 on visual acuity, contrast sensitivity and reading under conditions of FLS were negative but not clinically significant.