9 resultados para outcomes assessment
em Aston University Research Archive
Resumo:
Healthcare providers and policy makers are faced with an ever-increasing number of medical publications. Searching for relevant information and keeping up to date with new research findings remains a constant challenge. It has been widely acknowledged that narrative reviews of the literature are susceptible to several types of bias and a systematic approach may protect against these biases. The aim of this thesis was to apply quantitative methods in the assessment of outcomes of topical therapies for psoriasis. In particular, to systematically examine the comparative efficacy, tolerability and cost-effectiveness of topical calcipotriol in the treatment of mild-to-moderate psoriasis. Over the years, a wide range of techniques have been used to evaluate the severity of psoriasis and the outcomes from treatment. This lack of standardisation complicates the direct comparison of results and ultimately the pooling of outcomes from different clinical trials. There is a clear requirement for more comprehensive tools for measuring drug efficacy and disease severity in psoriasis. Ideally, the outcome measures need to be simple, relevant, practical, and widely applicable, and the instruments should be reliable, valid and responsive. The results of the meta-analysis reported herein show that calcipotriol is an effective antipsoriatic agent. In the short-tenn, the pooled data found calcipotriol to be more effective than calcitriol, tacalcitol, coal tar and short-contact dithranol. Only potent corticosteroids appeared to have comparable efficacy, with less short-term side-effects. Potent corticosteroids also added to the antipsoriatic effect of calcipotriol, and appeared to suppress the occurrence of calcipotriol-induced irritation. There was insufficient evidence to support any large effects in favour of improvements in efficacy when calcipotriol is used in combination with systemic therapies in patients with severe psoriasis. However, there was a total absence of long-term morbidity data on the effectiveness of any of the interventions studied. Decision analysis showed that, from the perspective of the NHS as payer, the relatively small differences in efficacy between calcipotriol and short-contact dithranol lead to large differences in the direct cost of treating patients with mildto-moderate plaque psoriasis. Further research is needed to examine the clinical and economic issues affecting patients under treatment for psoriasis in the UK. In particular, the maintenance value and cost/benefit ratio for the various treatment strategies, and the assessment of patient's preferences has not yet been adequately addressed for this chronic recurring disease.
Resumo:
Outcomes measures, which is the measurement of effectiveness of interventions and services has been propelled onto the health service agenda since the introduction of the internal market in the 1990s. It arose as a result of the escalating cost of inpatient care, the need to identify what interventions work and in what situations, and the desire for effective information by service users enabled by the consumerist agenda introduced by Working for Patients white paper. The research reported in this thesis is an assessment of the readiness of the forensic mental health service to measure outcomes of interventions. The research examines the type, prevalence and scope of use of outcomes measures, and further seeks a consensus of views of key stakeholders on the priority areas for future development. It discusses the theoretical basis for defining health and advocates the argument that the present focus on measuring effectiveness of care is misdirected without the input of users, particularly patients in their care, drawing together the views of the many stakeholders who have an interest in the provision of care in the service. The research further draws on the theory of structuration to demonstrate the degree to which a duality of action, which is necessary for the development, and use of outcomes measures is in place within the service. Consequently, it highlights some of the hurdles that need to be surmounted before effective measurement of health gain can be developed in the field of study. It concludes by advancing the view that outcomes research can enable practitioners to better understand the relationship between the illness of the patient and the efficacy of treatment. This understanding it is argued would contribute to improving dialogue between the health care practitioner and the patient, and further providing the information necessary for moving away from untested assumptions, which are numerous in the field about the superiority of one treatment approach over another.
Resumo:
The impact and use of information and communication technology on learning outcomes for accounting students is not well understood. This study investigates the impact of design features of Blackboard 1 used as aWeb-based Learning Environment (WBLE) in teaching undergraduate accounting students. Specifically, this investigation reports on a number of Blackboard design features (e.g. delivery of lecture notes, announcements, online assessment and model answers) used to deliver learning materials regarded as necessary to enhance learning outcomes. Responses from 369 on-campus students provided data to develop a regression model that seeks to explain enhanced participation and mental effort. The final regression shows that student satisfaction with the use of a WBLE is associated with five design features or variables. These include usefulness and availability of lecture notes, online assessment, model answers, and online chat.
Resumo:
This investigation seeks to explore the hypothesis, derived from observation and practice, that there is a strong relationship between the development of literacy skills and the growth of confidence in adult literacy students. Implicit in the developmental approach is the notion of progression towards some cognitive goal. Such a goal necessitates the establishment of a base line of existing attainment, together with subsequent assessment so that progress and development can be measured. The study includes an evaluation of existing formal and informal methods of initial and subsequent assessment and diagnosis available at the time for Adult Literacy Scheme Co-ordinators. Underlying the funding by Cheshire County Council for the project is the assumption that the results will be available for all practitioners and that the tools of measurement may be used by other Adult Literacy Co-ordinators in the County. It is intended, therefore, that this research should result in practical outcomes in which methods of assessment will involve active participation by students as well as by tutors, becoming part of the learning process. It is hypothesised that this kind of co-operation could lead ultimately to self-directed learning and student-independence. For the purposes of this research, a balance is attempted in the use of assessment tools, between standardised tests and informal methods. The study provides facts about students! reading habits; as well as their reading levels, their spelling levels, their handwriting, their writing skills and their writing habits. The study seeks to show the students' feelings towards education, their educational attainments and the type of school which they attended. The study also attempts to come to some measurement of those aspects of student personality which relate to confidence, by means of tests and questionnaires. The study concludes with an examination of the link between cognitive and affective progress.
Resumo:
The aim of this thesis was to develop standards of best practice for the subjective assessment of near visual function in presbyopia. Near visual acuity (VA) is a quick and simple measure but an assessment of the maximum reading speed and the smallest print size that can maintain this are equally important, to gain a better reflection of real world visual function. These metrics are dependent on the amplitude of accommodation (AoA) and often this must be evaluated using subjective techniques. Defocus curves are less susceptible than the push-up/push-down test to the influence of blur tolerance but their implementation must be standardised such that letter sequences and the order of lens presentation are randomised, to avoid memory effects, whilst the AoA should be quantified as the range of defocus for which only the best VA is maintained. In addition to such clinical assessments, subjective questionnaire evaluations are also important, to determine whether at least an individual’s needs are met. The Near Activity Visual Questionnaire (NAVQ) developed in this thesis can be used for this. Using these standardised near vision metrics it is shown that visual performance with monovision and multifocal contact lenses is comparable whilst initial outcomes of single optic ‘accommodating’ intraocular lens implantation are unlikely to be sustained in the long-term.
Resumo:
PURPOSE: To assess the clinical outcomes after implantation of a new hydrophobic acrylic toric intraocular lens (IOL) to correct preexisting corneal astigmatism in patients having routine cataract surgery. SETTING: Four hospital eye clinics throughout Europe. DESIGN: Cohort study. METHODS: This study included eyes with at least 0.75 diopter (D) of preexisting corneal astigmatism having routine cataract surgery. Phacoemulsification was performed followed by insertion and alignment of a Tecnis toric IOL. Patients were examined 4 to 8 weeks postoperatively; uncorrected distance visual acuity (UDVA), corrected distance visual acuity, manifest refraction, and keratometry were measured. Individual patient satisfaction with uncorrected vision and the surgeon’s assessment of ease of handling and performance of the IOL were also documented. The cylinder axis of the toric IOL was determined by dilated slitlamp examination. RESULTS: The study enrolled 67 eyes of 60 patients. Four to 8 weeks postoperatively, the mean UDVA was 0.15 logMAR G 0.17 (SD) and the UDVA was 20/40 or better in 88% of eyes. The mean refractive cylinder decreased significantly postoperatively, from -1.91 +/- 1.07 D to -0.67 +/- 0.54 D. No significant change in keratometric cylinder was observed. The mean absolute IOL misalignment from the intended axis was 3.4 degrees (range 0 to 12 degrees). The good UDVA resulted in high levels of patient satisfaction. CONCLUSION: Implantation of the new toric IOL was an effective, safe, and predictable method to manage corneal astigmatism in patients having routine cataract surgery.
Resumo:
Assessment criteria are increasingly incorporated into teaching, making it important to clarify the pedagogic status of the qualities to which they refer. We reviewed theory and evidence about the extent to which four core criteria for student writing-critical thinking, use of language, structuring, and argument-refer to the outcomes of three types of learning: generic skills learning, a deep approach to learning, and complex learning. The analysis showed that all four of the core criteria describe to some extent properties of text resulting from using skills, but none qualify fully as descriptions of the outcomes of applying generic skills. Most also describe certain aspects of the outcomes of taking a deep approach to learning. Critical thinking and argument correspond most closely to the outcomes of complex learning. At lower levels of performance, use of language and structuring describe the outcomes of applying transferable skills. At higher levels of performance, they describe the outcomes of taking a deep approach to learning. We propose that the type of learning required to meet the core criteria is most usefully and accurately conceptualized as the learning of complex skills, and that this provides a conceptual framework for maximizing the benefits of using assessment criteria as part of teaching. © 2006 Taylor & Francis.
Resumo:
Premium Intraocular Lenses (IOLs) such as toric IOLs, multifocal IOLs (MIOLs) and accommodating IOLs (AIOLs) can provide better refractive and visual outcomes compared to standard monofocal designs, leading to greater levels of post-operative spectacle independence. The principal theme of this thesis relates to the development of new assessment techniques that can help to improve future premium IOL design. IOLs designed to correct astigmatism form the focus of the first part of the thesis. A novel toric IOL design was devised to decrease the effect of toric rotation on patient visual acuity, but found to have neither a beneficial or detrimental impact on visual acuity retention. IOL tilt, like rotation, may curtail visual performance; however current IOL tilt measurement techniques require the use of specialist equipment not readily available in most ophthalmological clinics. Thus a new idea that applied Pythagoras’s theory to digital images of IOL optic symmetricality in order to calculate tilt was proposed, and shown to be both accurate and highly repeatable. A literature review revealed little information on the relationship between IOL tilt, decentration and rotation and so this was examined. A poor correlation between these factors was found, indicating they occur independently of each other. Next, presbyopia correcting IOLs were investigated. The light distribution of different MIOLs and an AIOL was assessed using perimetry, to establish whether this could be used to inform optimal IOL design. Anticipated differences in threshold sensitivity between IOLs were not however found, thus perimetry was concluded to be ineffective in mapping retinal projection of blur. The observed difference between subjective and objective measures of accommodation, arising from the influence of pseudoaccommodative factors, was explored next to establish how much additional objective power would be required to restore the eye’s focus with AIOLs. Blur tolerance was found to be the key contributor to the ocular depth of focus, with an approximate dioptric influence of 0.60D. Our understanding of MIOLs may be limited by the need for subjective defocus curves, which are lengthy and do not permit important additional measures to be undertaken. The use of aberrometry to provide faster objective defocus curves was examined. Although subjective and objective measures related well, the peaks of the MIOL defocus curve profile were not evident with objective prediction of acuity, indicating a need for further refinement of visual quality metrics based on ocular aberrations. The experiments detailed in the thesis evaluate methods to improve visual performance with toric IOLs. They also investigate new techniques to allow more rapid post-operative assessment of premium IOLs, which could allow greater insights to be obtained into several aspects of visual quality, in order to optimise future IOL design and ultimately enhance patient satisfaction.
Resumo:
Attention-deficit hyperactivity disorder (ADHD) is the most prevalent and impairing neurodevelopmental disorder, with worldwide estimates of 5.29%. ADHD is clinically characterized by hyperactivity-impulsivity and inattention, with neuropsychological deficits in executive functions, attention, working memory and inhibition. These cognitive processes rely on prefrontal cortex function; cognitive training programs enhance performance of ADHD participants supporting the idea of neuronal plasticity. Here we propose the development of an on-line puzzle game based assessment and training tool in which participants must deduce the ‘winning symbol’ out of N distracters. To increase ecological validity of assessments strategically triggered Twitter/Facebook notifications will challenge the ability to ignore distracters. In the UK, significant cost for the disorder on health, social and education services, stand at £23m a year. Thus the potential impact of neuropsychological assessment and training to improve our understanding of the pathophysiology of ADHD, and hence our treatment interventions and patient outcomes, cannot be overstated.