29 resultados para open field test

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: To evaluate the accuracy of an open-field autorefractor compared with subjective refraction in pseudophakes and hence its ability to assess objective eye focus with intraocular lenses (IOLs). Methods: Objective refraction was measured at 6 m using the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K open-field autorefractor (five repeats) and by subjective refraction on 141 eyes implanted with a spherical (Softec1 n=53), aspherical (SoftecHD n=37) or accommodating (1CU n=22; Tetraflex n=29) IOL. Autorefraction was repeated 2 months later. Results: The autorefractor prescription was similar (average difference: 0.09±0.53 D; p=0.19) to that found by subjective refraction, with ~71% within ±0.50 D. The horizontal cylindrical components were similar (difference: 0.00±0.39 D; p=0.96), although the oblique (J45) autorefractor cylindrical vector was slightly more negative (by -0.06±0.25 D; p=0.06) than the subjective refraction. The results were similar for each of the IOL designs except for the spherical IOL, where the mean spherical equivalent difference between autorefraction and subjective was more hypermetropic than the Tetraflex accommodating IOL (F=2.77, p=0.04). The intrasession repeatability was

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To validate a new miniaturised, open-field wavefront device which has been developed with the capacity to be attached to an ophthalmic surgical microscope or slit-lamp. SETTING: Solihull Hospital and Aston University, Birmingham, UK DESIGN: Comparative non-interventional study. METHODS: The dynamic range of the Aston Aberrometer was assessed using a calibrated model eye. The validity of the Aston Aberrometer was compared to a conventional desk mounted Shack-Hartmann aberrometer (Topcon KR1W) by measuring the refractive error and higher order aberrations of 75 dilated eyes with both instruments in random order. The Aston Aberrometer measurements were repeated five times to assess intra-session repeatability. Data was converted to vector form for analysis. RESULTS: The Aston Aberrometer had a large dynamic range of at least +21.0 D to -25.0 D. It gave similar measurements to a conventional aberrometer for mean spherical equivalent (mean difference ± 95% confidence interval: 0.02 ± 0.49D; correlation: r=0.995, p<0.001), astigmatic components (J0: 0.02 ± 0.15D; r=0.977, p<0.001; J45: 0.03 ± 0.28; r=0.666, p<0.001) and higher order aberrations RMS (0.02 ± 0.20D; r=0.620, p<0.001). Intraclass correlation coefficient assessments of intra-sessional repeatability for the Aston Aberrometer were excellent (spherical equivalent =1.000, p<0.001; astigmatic components J0 =0.998, p<0.001, J45=0.980, p<0.01; higher order aberrations RMS =0.961, p<0.001). CONCLUSIONS: The Aston Aberrometer gives valid and repeatable measures of refractive error and higher order aberrations over a large range. As it is able to measure continuously, it can provide direct feedback to surgeons during intraocular lens implantations and corneal surgery as to the optical status of the visual system.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background - An evaluation of standard automated perimetry (SAP) and short wavelength automated perimetry (SWAP) for the central 10–2 visual field test procedure in patients with age-related macular degeneration (AMD) is presented in order to determine methods of quantifying the central sensitivity loss in patients at various stages of AMD. Methods - 10–2 SAP and SWAP Humphrey visual fields and stereoscopic fundus photographs were collected in 27 eyes of 27 patients with AMD and 22 eyes of 22 normal subjects. Results - Mean Deviation and Pattern Standard Deviation (PSD) varied significantly with stage of disease in SAP (both p<0.001) and SWAP (both p<0.001), but post hoc analysis revealed overlap of functional values among stages. In SWAP, indices of focal loss were more sensitive to detecting differences in AMD from normal. SWAP defects were greater in depth and area than those in SAP. Central sensitivity (within 1°) changed by -3.9 and -4.9 dB per stage in SAP and SWAP, respectively. Based on defect maps, an AMD Severity Index was derived. Conclusions - Global indices of focal loss were more sensitive to detecting early stage AMD from normal. The SWAP sensitivity decline with advancing stage of AMD was greater than in SAP. A new AMD Severity Index quantifies visual field defects on a continuous scale. Although not all patients are suitable for SWAP examinations, it is of value as a tool in research studies of visual loss in AMD.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To determine whether the ‘through-focus’ aberrations of a multifocal and accommodative intraocular lens (IOL) implanted patient can be used to provide rapid and reliable measures of their subjective range of clear vision. Methods: Eyes that had been implanted with a concentric (n = 8), segmented (n = 10) or accommodating (n = 6) intraocular lenses (mean age 62.9 ± 8.9 years; range 46-79 years) for over a year underwent simultaneous monocular subjective (electronic logMAR test chart at 4m with letters randomised between presentations) and objective (Aston open-field aberrometer) defocus curve testing for levels of defocus between +1.50 to -5.00DS in -0.50DS steps, in a randomised order. Pupil size and ocular aberration (a combination of the patient’s and the defocus inducing lens aberrations) at each level of blur was measured by the aberrometer. Visual acuity was measured subjectively at each level of defocus to determine the traditional defocus curve. Objective acuity was predicted using image quality metrics. Results: The range of clear focus differed between the three IOL types (F=15.506, P=0.001) as well as between subjective and objective defocus curves (F=6.685, p=0.049). There was no statistically significant difference between subjective and objective defocus curves in the segmented or concentric ring MIOL group (P>0.05). However a difference was found between the two measures and the accommodating IOL group (P<0.001). Mean Delta logMAR (predicted minus measured logMAR) across all target vergences was -0.06 ± 0.19 logMAR. Predicted logMAR defocus curves for the multifocal IOLs did not show a near vision addition peak, unlike the subjective measurement of visual acuity. However, there was a strong positive correlation between measured and predicted logMAR for all three IOLs (Pearson’s correlation: P<0.001). Conclusions: Current subjective procedures are lengthy and do not enable important additional measures such as defocus curves under differently luminance or contrast levels to be assessed, which may limit our understanding of MIOL performance in real-world conditions. In general objective aberrometry measures correlated well with the subjective assessment indicating the relative robustness of this technique in evaluating post-operative success with segmented and concentric ring MIOL.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background There is a paucity of data describing the prevalence of childhood refractive error in the United Kingdom. The Northern Ireland Childhood Errors of Refraction study, along with its sister study the Aston Eye Study, are the first population-based surveys of children using both random cluster sampling and cycloplegic autorefraction to quantify levels of refractive error in the United Kingdom. Methods Children aged 6–7 years and 12–13 years were recruited from a stratified random sample of primary and post-primary schools, representative of the population of Northern Ireland as a whole. Measurements included assessment of visual acuity, oculomotor balance, ocular biometry and cycloplegic binocular open-field autorefraction. Questionnaires were used to identify putative risk factors for refractive error. Results 399 (57%) of 6–7 years and 669 (60%) of 12–13 years participated. School participation rates did not vary statistically significantly with the size of the school, whether the school is urban or rural, or whether it is in a deprived/non-deprived area. The gender balance, ethnicity and type of schooling of participants are reflective of the Northern Ireland population. Conclusions The study design, sample size and methodology will ensure accurate measures of the prevalence of refractive errors in the target population and will facilitate comparisons with other population-based refractive data.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Two in-fiber Bragg grating (FBG) temperature sensor systems for medical applications are demonstrated: (1) an FBG flow-directed thermodilution catheter based on interferometric detection of wavelength shift that is used for cardiac monitoring; and (2) an FBG sensor system with a tunable Fabry-Perot filter for in vivo temperature profiling in nuclear magnetic resonance (NMR) machines. Preliminary results show that the FBG sensor is in good agreement with electrical sensors that are widely used in practice. A field test shows that the FBG sensor system is suitable for in situ temperature profiling in NMR machines for medical applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

There is a growing demand for data transmission over digital networks involving mobile terminals. An important class of data required for transmission over mobile terminals is image information such as street maps, floor plans and identikit images. This sort of transmission is of particular interest to the service industries such as the Police force, Fire brigade, medical services and other services. These services cannot be applied directly to mobile terminals because of the limited capacity of the mobile channels and the transmission errors caused by the multipath (Rayleigh) fading. In this research, transmission of line diagram images such as floor plans and street maps, over digital networks involving mobile terminals at transmission rates of 2400 bits/s and 4800 bits/s have been studied. A low bit-rate source encoding technique using geometric codes is found to be suitable to represent line diagram images. In geometric encoding, the amount of data required to represent or store the line diagram images is proportional to the image detail. Thus a simple line diagram image would require a small amount of data. To study the effect of transmission errors due to mobile channels on the transmitted images, error sources (error files), which represent mobile channels under different conditions, have been produced using channel modelling techniques. Satisfactory models of the mobile channel have been obtained when compared to the field test measurements. Subjective performance tests have been carried out to evaluate the quality and usefulness of the received line diagram images under various mobile channel conditions. The effect of mobile transmission errors on the quality of the received images has been determined. To improve the quality of the received images under various mobile channel conditions, forward error correcting codes (FEC) with interleaving and automatic repeat request (ARQ) schemes have been proposed. The performance of the error control codes have been evaluated under various mobile channel conditions. It has been shown that a FEC code with interleaving can be used effectively to improve the quality of the received images under normal and severe mobile channel conditions. Under normal channel conditions, similar results have been obtained when using ARQ schemes. However, under severe mobile channel conditions, the FEC code with interleaving shows better performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: The binocular Esterman visual field test (EVFT) is the current visual field test for driving in the UK. Merging of monocular field tests (Integrated Visual Field, IVF) has been proposed as an alternative for glaucoma patients. Aims: To examine the level of agreement between the EVFT and IVF for patients with binocular paracentral scotomata, caused by either ophthalmological or neurological conditions, and to compare outcomes with useful field of view (UFOV) performance, a test of visual attention thought to be important in driving. Methods: 60 patients with binocular paracentral scotomata but normal visual acuity (VA) were recruited prospectively. Subjects completed and were classified as “pass” or “fail” for the EVFT, IVF and UFOV. Results: Good agreement occurred between the EVFT and IVF in classifying subjects as “pass” or “fail” (kappa?=?0.84). Classifications disagreed for four subjects with paracentral scotomata of neurological origin (three “passed” IVF yet “failed” EVFT). Mean UFOV scores did not differ between those who “passed” and those who “failed” both visual field tests (p?=?0.11). Agreement between the visual field tests and UFOV was limited (EVFT kappa?=?0.22, IVF kappa 0.32). Conclusions: Although the IVF and EVFT agree well in classifying visual fields with regard to legal fitness to drive in the UK, the IVF “passes” some individuals currently classed as unfit to drive due to paracentral scotomata of non-glaucomatous origin. The suitability of the UFOV for assessing crash risk in those with visual field loss is questionable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose. The prevalence of myopia is known to vary with age, ethnicity, level of education, and socioeconomic status, with a high prevalence reported in university students and in people from East Asian countries. This study determines the prevalence of ametropia in a mixed ethnicity U.K. university student population and compares associated ocular biometric measures. Methods. Refractive error and related ocular component data were collected on 373 first-year U.K. undergraduate students (mean age = 19.55 years ± 2.99, range = 17-30 years) at the start of the academic year at Aston University, Birmingham, and the University of Bradford, West Yorkshire. The ethnic variation of the students was as follows: white 38.9%, British Asian 58.2%, Chinese 2.1%, and black 0.8%. Noncycloplegic refractive error was measured with an infrared open-field autorefractor, the Shin-Nippon NVision-K 5001 (Shin Nippon, Ryusyo Industrial Co. Ltd, Osaka, Japan). Myopia was defined as a mean spherical equivalent (MSE) less than or equal to -0.50 D. Hyperopia was defined as an MSE greater than or equal to +0.50 D. Axial length, corneal curvature, and anterior chamber depth were measured using the Zeiss IOLMaster (Carl Zeiss, Jena, GmBH). Results. The analysis was carried out only for white and British Asian groups. The overall distribution of refractive error exhibited leptokurtosis, and prevalence levels were similar for white and British Asian (the predominant ethnic group) students across each ametropic group: myopia (50% vs. 53.4%), hyperopia (18.8% vs. 17.3%), and emmetropia (31.2% vs. 29.3%). There were no significant differences in the distribution of ametropia and biometric components between white and British Asian samples. Conclusion. The absence of a significant difference in refractive error and ocular components between white and British Asian students exposed to the same educational system is of interest. However, it is clear that a further study incorporating formal epidemiologic methods of analysis is required to address adequately the recent proposal that juvenile myopia develops principally from myopiagenic environments and is relatively independent of ethnicity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To field test the hypothesis that lichen thalli can use environmental sources of carbon, solutions of ribitol, arabitol and mannitol were added to intact thalli of Xanthoparmelia conspersa (Ach.) Hale and a yellow species of Rhizocarpon (Rhizocarpon Ram. Em. Th. Fr. subgenus Rhizocarpon). In addition, ribitol and an arabitol/mannitol mixture were added to the marginal hypothalli of Rhizocarpon thalli after removal of the areolae. Carbohydrates were added at the beginning of 2- or 3-month growth periods for up to 15 months at concentrations approximately three times the levels estimated to be in the thalli. Addition of carbohydrates to intact thalli of both species had no effect on total radial growth but addition of mannitol significantly increased growth of X. conspersa thalli in the September/October growth period in one experiment. However, this effect was not repeated in a subsequent experiment in which different concentrations of mannitol were added to intact thalli. Addition of ribitol to hypothalli of Rhizocarpon resulted in significantly increased growth in the first few months of the experiment, growth then declining to levels below that of untreated thalli. The data suggest that although hypothalli of Rhizocarpon may have the ability to utilise exogenous carbohydrates for growth, there was little evidence that intact thalli of either species utilise environmental sources of carbon in the field.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Rolls-Royce fuel cell systems is developing megawatt scale power systems based on solid oxide fuel cell technology. The hybrid design promises to meet challenging energy efficiency, cost and performance targets in a grid friendly fashion. Analysis and testing to date indicate that those targets can be met and enable a wealth of fuel cell applications to meet customer and existing grid and modern grid requirements. Working with a global development team, a series of laboratory tests and evaluations are completed and future field test and evaluation and demonstration planned.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

It has long been sought to measure ocular accommodation continuously in human factor applications such as driving or flying. Open-field autorefractors such as the Canon R-1 could be converted to allow continuous, objective recording, but steady eye fixation and head immobilisation were essential for the measurements to be valid. Image analysis techniques utilised by newer open-view autorefractors such as the Shin-Nippon SRW-5000 are more tolerant to head and eye movements, but perhaps the technique with the greatest potential for the measurement of accommodation in human factor applications is photoretinoscopy. This paper examines the development of techniques for high temporal measurements of accommodation and reports on the tolerance of one such recent commercial instrument, the PowerRefractor (PlusOptiX). The instrument was found to be tolerant to eye movements from the optical axis of the instrument (∼0.50 DS change in apparent accommodation with gaze 25° eccentric to the optical axis), longitudinal head movement (<0.25 DS from 8 cm towards and 20 cm away from the correct photorefractor to eye distance) and changes in background illuminance (<0.25 DS from 0.5 to 20 cd m-2 target luminance). The PowerRefractor also quantifies the direction of gaze and pupil size, but is unable to take measurements with small pupils <3.7 ±1.0 mm. © 2002 The College of Optometrists.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The need to measure the response of the oculomotor system, such as ocular accommodation, accurately and in real-world environments is essential. New instruments have been developed over the past 50 years to measure eye focus including the extensively utilised and well validated Canon R-1, but in general these have had limitations such as a closed field-of-view, a poor temporal resolution and the need for extensive instrumentation bulk preventing naturalistic performance of environmental tasks. The use of photoretinoscopy and more specifically the PowerRefractor was examined in this regard due to its remote nature, binocular measurement of accommodation, eye movement and pupil size and its open field-of-view. The accuracy of the PowerRefractor to measure refractive error was on averaging similar, but more variable than subjective refraction and previously validated instrumentation. The PowerRefractor was found to be tolerant to eye movements away from the visual axis, but could not function with small pupil sizes in brighter illumination. The PowerRefractor underestimated the lead of accommodation and overestimated the slope of the accommodation stimulus response curve. The PowerRefractor and the SRW-5000 were used to measure the oculomotor responses in a variety of real-world environment: spectacles compared to single vision contract lenses; the use of multifocal contact lenses by pre-presbyopes (relevant to studies on myopia retardation); and ‘accommodating’ intraocular lenses. Due to the accuracy concerns with the PowerRefractor, a purpose-built photoretinoscope was designed to measure the oculomotor response to a monocular head-mounted display. In conclusion, this thesis has shown the ability of photoretinoscopy to quantify changes in the oculomotor system. However there are some major limitations to the PowerRefractor, such as the need for individual calibration for accurate measures of accommodation and vergence, and the relatively large pupil size necessary for measurement.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This thesis sets out to examine in detail the condition of systemic hypertension (high Blood Pressure) in relation to optometric practice in the United Kingdom. Systemic hypertension, which is asymptomatic in the early stages, is diagnosed from the Blood Pressure (BP) measurement recorded by a sphygmomanometer and/or from the complications that have developed in target organs. Optometric practice based surveys revealed that diagnosed systemic hypertension was the most prevalent cardiovascular medical condition (20.5%). Measurement of BP of patients in this sample revealed that if an optometrist included sphygmomanometry into the sight examination then at least one patient each day would be referred for suspect systemic hypertension. Optometric opinion felt that the measurement of BP in optometric practice would advance the profession, being appreciated by both patients and General Practitioners (GPs), but was felt to be an unnecessary routine procedure. The present sight examination for the systemic hypertensive is similar to that of the normotensive patient, but may involve an altered fundus examination and a visual field test. The GPs were in favour of optometric BP measurement and a future role in the share care management of the systemic hypertensive. The application of a new pictorial grading scale for the grading of vascular changes associated with pre-malignant systemic hypertension was found to be both accurate and reliable. Clinical trial of the grading scale in optometric practice found positive correlations between BP and increasing severity of the retinal vascular features. The subtle pre-malignant vascular changes require reliable accurate detection and analysis to assist in the management of the systemic hypertensive patient. Vessel width was shown to decrease with increasing age. Image analysis of the A/V ratio, arteriolar tortuosity and focal calibre changes revealed a positive correlation to the patient's BP (p<0.001). The retinal vasculature is relatively stable longitudinally with only minor changes in response to early disease states. Age and elevated BP increased a patient's risk of developing systemic medical conditions over a two-year period. The application of the pictorial grading scale to optometric practice and training the optometrist in the use of sphygmomanometry would improve the management of the systemic hypertensive patient in optometric practice. Future advances in image analysis hold substantial benefits for the detection and monitoring of subtle vascular changes associated with systemic hypertension.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this research was to investigate the effects of normal aging and the additional effects of chronic exposure to two experimental diets, one enriched in aluminium, the other enriched in lecithin, on aspects of the behaviour and brain histology of the female mouse. The aluminium diet was administered in an attempt to develop a rodent model of Dementia of the Alzheimer Type (DAT). With normal aging, almost all assessed aspects of behaviour were found to be impaired. As regards cognition, selective impairments of single-trial passive avoidance and Morris place learning were observed. While all aspects of open-field behaviour were impaired, the degree of impairment was directly related to the degree of motoric complexity. Deficits were also observed on non-visual sensorimotor coordination tasks and in olfactory discrimination. Histologically, neuron loss, gliosis, vacuolation and congophilic angiopathy were observed in several of the brain regions/fibre tracts believed to contribute to the control of some of the assessed behaviours. The aluminium treatment had very selective effects on both behaviour and brain histology, inducing several features observed in DAT. Behaviourally, the treatment induced impaired spatial reference memory; reduced ambulation; disturbed olfactory function and induced the premature development of the senile pattern of swimming. Histologically, significant neuron loss and gliosis were observed in the hippocampus, entorhinal cortex, amygdala, medial septum, pyriform and pr-frontal cortex. In addition, the brain distribution of congophilic angiopathy was significantly increased by the treatment. The lecithin treatment had effects on both non-cognitive and cognitive aspects of behaviour. The effects of aging on open-field ambulation and rearing were partially ameliorated by the treatment. A similar effect was observed for single-trial passive avoidance performance. Age-dependent improvements in acquisition/retention were observed in 17-23 month mice and Morris place task performance was improved in 11 and 17 month mice. Histologically, a partial sparing of neurons in the cerebellum, hippocampus, entorhinal cortex and subiculum was observed.